50 kVA pole transformers

50 kVA pole transformers nwere Dual Voltage & IFD nchebe - na-arụ ọrụ nke ọma, ịwa ahụ{2}} ike dị njikere maka netwọk nkesa osimiri na ime obodo.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

A haziri 50 kVA otu -pase pole{2}} nke etinyere n'elu transformer maka ikesa oke n'akụkụ osimiri na ime obodo. Ọ na-arụ ọrụ na 60 Hz ma na-akwado abụọ isi voltaji (24,940 GRDY ma ọ bụ 14,400 V), na-enye ohere echichi na dị iche iche feeders mgbe na-enye 120/240 V mmepụta na nke abụọ. Ngalaba ahụ na-eji windings aluminom na isi igwe laminated, yana ONAN jụrụ oyi na ịnweta{12}mmanụ n'ime tank mechiri emechi maka ndụ dị n'èzí. Ọ na-enweta arụmọrụ karịrị ma ọ bụ nhata 99.04%, na-enweghị mfu 130 W, ibu ibu 492 W, yana impedance 2.16% (± 10%). Ihe na-adịghị{21}Load Tap Changer (NLTC) ±2 × 2.5% na-eme ka voltaji kwụsie ike n'okpuru ibu na-agbanwe.

Ihe ngbanwe ahụ na-ebukwa 9kV dị elu{1} voltaji na-ejide ọkụ iji kụchie àmụ̀mà ma na-atụgharị n'ala tupu ha enwee ike mesie mkpuchi mkpuchi ma ọ bụ mebie windings - ihe dị mkpa maka ndị na-eri nri ekpughere na égbè eluigwe, ịgba nnu, na ifufe/ice oyi. Akụkụ abụọ - voltaji na-enye ụlọ ọrụ ohere idobe ụdị ngbanwe dị ole na ole ma wụnye nkeji ngwa ngwa n'oge nkwụsị ma ọ bụ nkwalite. Site na nrịbama kVA 50, ọ nwere ike ijere ọtụtụ ụlọ na azụmaahịa karịa ihe ngbanwe 25 kVA, na-eme ka ọ bụrụ ihe a pụrụ ịdabere na ya, dị ala{8} ihe ndozi maka netwọk nkesa osimiri na ime obodo.

 

 

 

1.2 Nkọwa nka nka

50kVA osisi ntụgharị nkọwapụta na mpempe akwụkwọ data

Enyere ya
Canada
Afọ
2025
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
CSA C2.2-06/C802.1-23
Enyere ike
50KVA
Ugboro ugboro
60HZ
Usoro
Naanị otu
Ụdị oyi
ONAN
Ihe mgbochi mmiri
Mineral Mmanụ
Voltaji nke mbụ
24940GRDY/14400 V
Voltaji nke abụọ
120 / 240 V
Otu Vector
Ii6
Polarity
Ihe mgbakwunye
Ngwa ikuku
Aluminom
Mgbochi
2.16%(±10%)
Ịrụ ọrụ
Karịrị ma ọ bụ hà nhata 99.04%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
130 W
Ibu Mfu na Voltaji akwadoro
492 W
Ngwa ngwa
9kV HV onye njide

 

1.3 Eserese

50kVA osisi ntụgharị eserese na aha aha

50 kVA pole transformers drawing 50 kVA pole transformers nameplate

 

 

Nhazi ahaziri maka ọnọdụ ihu igwe dị n'ụsọ osimiri

Ebe saịtị nrụnye dị n'akụkụ osimiri{0} nwere ikuku iru mmiri, mmiri ozuzo na-agakarị, yana ntakịrị nnu n'ikuku{1} anyị gafere n'usoro ntọala wee mee nkwalite ole na ole ezubere iche:

 

1. Ihe mkpuchi mkpuchi ọkụ ọkụ ọkụ dị elu {{1}

 

Anyị gara n'ihu ma tinye mkpuchi nchebe na elu{0}voltaji bushings{1}karịsịa iji mee ka mkpuchi ahụ nwee obi ụtọ na kwụsie ike. Ị mara, na mmiri mmiri, mmiri ozuzo, mgbe ụfọdụ naanị ebe mmiri dị larịị, mkpuchi ekpughere bụ ụdị ịrịọ nsogbu. Ihe mkpuchi ndị a? Ha na-echebe ya pụọ ​​​​na mmiri mmiri, ikuku dị n'ụsọ oké osimiri, na obere ihe niile nwere ike ime ka ndụ sie ike maka ihe ntụgharị.

High-Voltage Bushing Protective Covers
 
High-Voltage Bushing Protective Covers drawing

2. 9 kV HV onye njide

Mgbe ahụ, e nwere 9 kV HV njide. Obere, ee, mana ọ bụ nnukwu ihe mgbe mkpọtụ voltaji ndị ahụ tụrụ{2} ebili mmiri, ịgbanwee, ma ọ bụ naanị ọnọdụ ihu igwe dị n'ụsọ oké osimiri. Ọ bụ ebe ahụ ijide ha, kwụsị flashovers, na ihu ọma na-edebe usoro si freaking si n'ụbọchị ọjọọ.

9 KV HV Arrester

 

 

02 Nrụpụta

2.1 Isi

50 kVA pole transformers iron core

A na-eme isi ọnya ahụ maka ojiji n'èzí. Nhazi ya juru eju na-egbochi ịma jijiji ma na-eme ka transformer kwụgidere n'osisi. Ọ na-ebelata enweghị ibu ibu -, na-arụ ọrụ nke ọma na ndị na-eri nri ogologo oge, ma nwee ike ijikwa ifufe, ice, na ihu igwe ndị ọzọ, na-enye ụlọ na obere ụlọ ọrụ ọkụ eletrik a pụrụ ịdabere na ya.

 

2.2 Ikuku

50 kVA pole transformers copper winding
50 kVA pole transformers iron and coil

Ogwe a - mgbakwasa mgbanaka na-eji obere ikuku - voltaji na-ekugharị ikuku yana igwe ikuku dị elu{2}, ọla kọpa na aluminom jikọtara. Foil nke LV na-eme ka mgbochi dị ala. Okpomọkụ na-agbasa nke ọma. Waya HV na-agbanwe agbanwe, na-ejikwa mgbanwe mgbanwe. Ọla kọpa-ngwakọta aluminom{8}} na-edozi arụmọrụ yana ọnụ ahịa ya. Kwesịrị ntụkwasị obi, na-adịgide adịgide, dabara obere grids, azụmahịa ebe obibi ma ọ bụ ọkụ, kwa ụbọchị.

 

 

03 Nnwale

50 kVA pole transformers testing-1
50 kVA pole transformers testing-2

 

 

04 Mbukota na njem

4.1 mbukota

50 kVA pole transformers waiting for packing
50 kVA pole transformers in box

 

4.2 Mbupu

50 kVA pole transformers shipping-1
50 kVA pole transformers shipping-2

 

 

05 FAQ

50 kVA pole transformers on the pole line

Q1: Ọ dị mma ịwụnye transformer na iru mmiri ma ọ bụ gburugburu osimiri?

Ee, n'ozuzu ọ dị mma. Mana, ebe dị n'ụsọ oké osimiri{1}} iru mmiri, nnu na ikuku, mgbe ụfọdụ naanị mmiri na iru mmiri{2} nwere ike isi ike na transformer. Ya mere anyị ji akwado iru mmiri{4}} ụkpụrụ na-eguzogide, dị ka elu- voltaji mkpuchi mkpuchi, corrosion - ihe ndị na-eguzogide, na ala siri ike. Na-enyere aka igbochi ihe mkpuchi mkpuchi. Na-eme ka ihe na-aga ogologo oge. Nyocha ngwa ngwa ugbu a wee nweta nsogbu n'oge.

Q2: Transformer nwere ike ikpo ọkụ?

Ọ nwere ike. Karịsịa ma ọ bụrụ na ibu dị elu, ma ọ bụ na ọ na-agba ọsọ mgbe niile, ma ọ bụ ventilashion adịghị mma. Mbụ ị ga-achọ nha nha kwesịrị ekwesị. Na-ajụ oyi? Dị oke mkpa. Okpomọkụ mmanụ ma ọ bụ okpomoku ikuku{4}} nyochaa ha. Wepụtakwa transformer nke nwere ogo ịrị elu okpomọkụ kwesịrị ekwesị maka ibu ị tụrụ anya ya. Oke oke ọkụ, mkpuchi na-eto ngwa ngwa, arụmọrụ dara ada, ihe egwu nke ọdịda na-ebili.

Q3: Ọ dị mkpa ijide ọkụ ọkụ?

Ee, ike. Ọbụna obere mgbawa, àmụmà, na-agbanwe spikes{1}ha na-eme. Na-enweghị onye njide ịwa ahụ, mkpuchi nwere ike daa, ọkụ ọkụ nwere ike ime, ndụ transformer na-ebelata. Ngwa dị mfe, ma ọ na-eme nnukwu ọdịiche. Oké ifufe dị n'ụsọ oké osimiri ma ọ bụ grids na-akwụghị ọtọ{5}} njide bụ n'ezie udo nke obi.

Q4: Ugboro ole ka a ga-edobe transformer?

Ọ dịkarịa ala otu ugboro n'afọ. Nnwale eletriki - nguzogide mkpuchi, nguzogide ikuku, nlele nha. Na-agbada- hụ na ọ siri ike, nguzogide dị ala. Ihe mkpuchi - na-achọ mgbawa, corrosion, mmiri mmiri. Ngwa imi -mmanu? Nyocha mma mmanụ, DGA, mmiri mmiri, acidity. Ọtụtụ mgbe, ọ bụrụ na ibu dị arọ ma ọ bụ gburugburu ebe obibi siri ike. Na-eme ka ọ na-agba ọsọ, na-ezere ihe ịtụnanya.

 

 

Ihe nchịkọta dị ọkụ: pole transformers, onye nrụpụta, soplaya, price, ọnụ