Obere mgbanwe (erughị ma ọ bụ hara na 15MVA)

Scotech na-enye onye na-agbanwe ihe ruru 15 mVA 69 kV

Kpọtụrụ ahịa
  • Inye onyinye
  • Akwụkwọ
Ichoputa
Obere mgbanwe (erughị ma ọ bụ hara na 15MVA)
Ruo 15 mva 69 kV
Obere ndị na-agbanwe agbanwe bụ ihe dị mkpa na sistemụ eletriki, nke e mere iji rụọ ọrụ nke ọma na-ebufe ikuku eletriki n'etiti sekit site na ntinye eletriki. Ma ọ bụ na ha na-ekpo ọkụ ma ọ bụ ala iji kwekọọ na mkpa nke ngwa dị iche iche - site na ike ụlọ obibi na elektrọnikị iji na-akwado akụrụngwa dị oke mkpa na ntọala mmepụta ọrụ. O zipụrụ injinia nke a ga-eme ka ọ dịkwuo mfe, ha na-ahụ nhazi ọnọdụ ọkụkụ ọkụ ọkụ, mkpuchi ntụkwasị obi, na ezigbo ndụ. Ma na netwọk ike kesara, usoro nrụpụta, ma ọ bụ ngwaọrụ Starfoner, transformers ndị a na-ebugharị nke dị ala, na-eweta arụmọrụ nke dị ala -} na-eji arụ ọrụ arụmọrụ.
Budata broshuọ

3150 KVA Transformer in Power System 7

Uru
  • Mfe
    Echichi
  • Ike nke Ọma
    Mmife
  • Agwaziri
    Osisa
  • Nkwado ndị teknuzu
    Oru
EGO
6 MVA Three Phase Power Transformer 1

Nkowa

• ọkọlọtọ emebere dịka iC, Ani / nema, CSA, wdg

• Ike Raable ruo 15 mva

• Ulo elu dị elu ruo 69 kV

• Ugboro 50 ma ọ bụ 60 Hz

• fr3, mmanụ mineral, silicone, hydrocarbon na mmanụ oriri dị

• Ọnọdụ okpomọkụ: 55 ogo, ogo 65, ogo 55/65

• Ihe eji eme ihe: IGBO 1-4

• Ihe ndị dị elu na ndị dị elu dị elu dị

• Galvanized ma ọ bụ igwe anaghị agba nchara-} radiaters

• Ndị na-ese okwu na-ese ihe:> 1000 awa nnu ịgbara mmiri maka ọnọdụ n'èzí

• Buchholz Relay, BCC

• Enwere ike ịhazi ọkwa electrostatic, enwere ike ịhazi arịrịọ ndị ọzọ pụrụ iche.

 

 

  • download

    Akwụkwọ ntuziaka maka transforner Power

    Budata
  • download

    Mmanụ mmanụ -} na-emegharị ike mgbanwe ike

    Budata

 

 

Nrutuaka
15 MVA Nzọụkwụ Up Power Transformer-4.16 / 69 kV|Guyana 2023
15 MVA Nzọụkwụ Up Power Transformer-4.16 / 69 kV|Guyana 2023
Obodo: Guyana 2023
Ike: 15MVA
Voltaji: 4.16/69kV
Njirimara: ya na OLTC
10 MVA Main Power Transformer-33/33 kV|South Africa 2025
10 MVA Main Power Transformer-33/33 kV|South Africa 2025
Obodo nzipu: South Africa 2025
Ike: 10MVA
Voltaji: 33/33kV
Njirimara: +8*2.5%, -8*2.5%@akụkụ isi
8 MVA Obere ike ntụgharị-33/33 kV|Zimbabwe 2024
8 MVA Obere ike ntụgharị-33/33 kV|Zimbabwe 2024
Obodo: Zimbabwe 2022
Ike: 8MVA
Voltaji: 33/33kV
Njirimara: ya na OLTC
6 MVA Atọ Atọ Ike Ntugharị-33 / 6.6 kV|South Africa 2024
6 MVA Atọ Atọ Ike Ntugharị-33 / 6.6 kV|South Africa 2024
Obodo: South Africa 2024
Ike: 6 MVA
Voltaji: 33/6.6 kV
Njirimara: Hot galvanized
6 MVA Igwe ọkụ eletrik na-eme mgbanwe-33 / 2.2 kV|South Africa 2025
6 MVA Igwe ọkụ eletrik na-eme mgbanwe-33 / 2.2 kV|South Africa 2025
Obodo nzipu: South Africa 2024
Ike: 6MVA
Voltaji: 33/2.2kV
Njirimara: Igwe ọkụ na-ekpo ọkụ- itinye galvanized radiator
3150 kVA Transformer Na Sistemụ Ike-0.4 / 6.6 kV|South Africa 2025
3150 kVA Transformer Na Sistemụ Ike-0.4 / 6.6 kV|South Africa 2025
Obodo: South Africa 2025
Ike: 3150 kVA
Voltaji: 0.4/6.6 kV
Njirimara: Hot galvanized
3000 kVA omenala ndị na-agbanwe ike-33/11 kV|South Africa 2025
3000 kVA omenala ndị na-agbanwe ike-33/11 kV|South Africa 2025
Obodo nzipu: South Africa 2025
Ike: 3MVA
Voltaji: 33/11kV
Njirimara: Oke ịpị ± 6*1.8%
3500 KVA Industrial Power Transformers-33/11 KV|Papua New Guinea 2025
3500 KVA Industrial Power Transformers-33/11 KV|Papua New Guinea 2025
Obodo nzipu: Papua new Guinea 2025
Ike: 3.5MVA
Voltaji: 33/11kV
Njirimara: Ọkara Stable -Ike voltaji
10 MVA Best Power Transformers-33/11 KV|South Africa 2025
10 MVA Best Power Transformers-33/11 KV|South Africa 2025
Obodo: South Africa 2025
Ike: 10 MVA
Voltaji: 33/11kV
Njirimara: ya na OLTC
1000 KVA Railroad Transformer-66/11 KV|South Africa 2025
1000 KVA Railroad Transformer-66/11 KV|South Africa 2025
Obodo: South Africa 2025
Ike: 1000 kVA
Voltaji: 66/11 kV
Njirimara: Obere- voltaji n'akụkụ mpụta
13.3 MVA GSU transformanter-13.8 / 4.16 KV|Canada 2025
13.3 MVA GSU transformanter-13.8 / 4.16 KV|Canada 2025
Ngalaba Nzigharị: Canada 2025
Ikike: 10 / 13.3mva
Voltage: 13.8 / 4.16KV
Njirimara: Njirimara Toturitrol