50kva Ogwe Ntugharị-7.2 / 0.12 * 0.24 KV|Canada 2025

50kva Ogwe Ntugharị-7.2 / 0.12 * 0.24 KV|Canada 2025

Obodo nzipu: Canada 2025
Ike: 50kVA
Voltaji: 7.2-0.12/0.24kV
Njirimara: Voltaji abụọ & Nchekwa IFD
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị a pụrụ ịdabere na ya na-emepụta na ndị na-eweta 50kva pole mounted transformer-7.2/0.12*0.24 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

50kva pole mounted transformer

50kVA pole agbakwunyere transformer - Dual Voltage & IFD, wuru maka nkesa Canada kwesịrị ntụkwasị obi

 

 

01 Izugbe

1.1 Nkọwa oru ngo

Nke a 50 kVA otu -Ogwe osisi - mgbakwasa ngbanwe na-ebunye ike dị nchebe na ntụkwasị obi maka ụlọ na obere azụmaahịa. A na-agbanye ya n'osisi ọrụ wee gbadata elu{4} ọkụ eletrik sitere na netwọk nkesa (12,470 GRDY/7,200 V) ruo ọkwa 120/240 V maka sistemụ North America 60 Hz.

Ihe ngbanwe ahụ nwere isi igwe laminated nke na-ebufe ike nke ọma n'etiti windings nke mbụ na nke abụọ. A na-eji aluminom dị mma- kpụ ọkụ n'ọnụ ma kpuchie ya nke ọma iji jikwaa nrụgide eletriki. Ngalaba ahụ na-enweta arụmọrụ dị elu (Karịrị ma ọ bụ nhata 99.04%) na enweghị - ibu ọnwụ nke 130 W yana mfu nke 492 W, yana atụmatụ 2.15% impedance (± 10%) maka ụkpụrụ voltaji na-agbanwe agbanwe n'okpuru ibu. Ihe na-adịghị{10}Load Tap Changer (NLTC) nwere oke mgbatụ ±2×2.5% na-enye ohere mgbanwe voltaji dị mma. Ihe nchọta mmejọ ime n'ime (IFD) agbakwunyere na-enyocha ihe ntụgharị maka okwu dị n'ime. Igwe ọkụ 9kV dị elu{16}} na-echebe megide ọnya. Ihe ngbanwe na-eji ONAN jụrụ oyi yana mkpuchi mmanụ ịnweta iji hụ na ntụkwasị obi dị ogologo oge{18} n'èzí.

Ihe ngbanwe a dị mma maka mpaghara obibi, ugbo na obere ụlọ ọrụ azụmahịa. Ọ na-arụ ọrụ nke ọma maka netwọk nkesa ime obodo na ime obodo, ndọtị netwọkụ, na ntọala ike nwa oge. Tankị ya mechiri emechi na nhazi siri ike na-eme ka ọ bụrụ ntụkwasị obi na ọnọdụ mpụga siri ike dị ka snow, mmiri ozuzo na oke okpomọkụ.

 

 

 

1.2 Nkọwa nka nka

50kVA okporo osisi n'ịnyịnya ntụgharị nkọwapụta na mpempe akwụkwọ data

Enyere ya
Canada
Afọ
2025
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
CSAC2.2-06/C802.1-23
Enyere ike
50KVA
Ugboro ugboro
60HZ
Usoro
Naanị otu
Ụdị oyi
ONAN
Ihe mgbochi mmiri
Mineral Mmanụ
Voltaji nke mbụ
12470GRDY/7200 V
Voltaji nke abụọ
120/ 240 V
Otu Vector
Ii6
Polarity
Ihe mgbakwunye
Ngwa ikuku
Aluminom
Mgbochi
2.15%(±10%)
Ịrụ ọrụ
Karịrị ma ọ bụ hà nhata 99.04%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
130 W
Na Ibu Mfu
492 W
Ngwa ngwa
9kV HV onye njide

 

1.3 Eserese

50kVA okporo osisi atụkwasịrị ihe ngbanwe na eserese na aha aha

50kva pole mounted transformer drawing 50kva pole mounted transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

50kva pole mounted transformer iron core

N'elu okporo osisi - agbakwunyere igwe nrụnye, a na-ewukwa isi ya ka ọ bụrụ kọmpat na ịma jijiji{1}} ka ọ nwee ike ịnọdụ ala n'enweghị nsogbu n'osisi ọrụ. Ọ na-adabere na ikuku, ice, na ọnọdụ ndị ọzọ dị n'èzí, ebe ị na-edebe enweghị - ibu mfu dị ala - nke bụ isi maka ahịrị dị ogologo na-enye nri ụlọ na obere azụmaahịa.

 

2.2 Ikuku

50kva pole mounted transformer coil
50kva pole mounted transformer copper coil

Ndị otu nwere ahụmahụ na-agbaso usoro doro anya na-eme mkpuchi anyị. Ndị na-arụ ọrụ na-ekpuchi foil nke ọma maka mkpuchi mkpuchi LV na ikuku ọla kọpa maka mkpuchi mkpuchi HV. Ndị nlekọta na-enyocha usoro a wee banye na ule ikpeazụ. Ngwakọta nka, ndenye ego, na ịrụkọ ọrụ ọnụ na-eme ka ndị na-agbanwe agbanwe bụrụ ndị a pụrụ ịtụkwasị obi na ọnọdụ ubi siri ike.

 

2.3 tank

Ihe ngbanwe ahụ na-eji tank mmanụ emechiri emechi{0} nke mechiri nke ọma, nrụgide{1} siri ike, nke ejiri ihe mgbado siri ike rụọ. Enweghị pores, enweghị ọnụ mmiri dị nro. Mgbe ịgbado ọkụ, tank na-aga site na agụụ ma ọ bụ ikuku{4}}ule ike. Sistemu mkpuchi mkpuchi dị n'èzí-ọkwa: epoxy primer gbakwunyere polyurethane imecha, yana corrosion ngwaike niile- echekwara Ọnụ ụzọ na-eso usoro ọkọlọtọ, na-edobe oghere maka ndị njide na ebe mgbakwasị ụkwụ na-emetụtaghị ike ibuli elu ma ọ bụ akụkụ mgbago. Zuru oke maka ihu igwe siri ike yana ogologo ọrụ.

50kva pole mounted transformer oil tank

 

 

03 mbukota na njem

3.1 mbukota

50kva pole mounted transformer waiting for packing
50kva pole mounted transformer packing

 

 

4.2 Mbupu

50kva pole mounted transformer shipping-1
50kva pole mounted transformer shipping-2

 

 

04 Nwụnye

Nwụnye nke okporo osisi -Mounted Transformer
Nkwadebe saịtị

Họrọ ebe kwesịrị ekwesị maka transformer. Ala kwesịrị ịdị na-eguzosi ike ma nweta ya, saịtị ahụ kwesịrị ịdị nso na eriri ọkụ dị ugbu a. Kpochapụ nkume, ahịhịa, ma ọ bụ ihe mgbochi ọ bụla dị na mpaghara ahụ.
Nyocha osisi
Nyochaa okporo osisi bara uru tupu echichi. Gbaa mbọ hụ na ọ dabara nke ọma, enweghị mgbawa ma ọ bụ ire ere, ma nwee ike ịkwado ịdị arọ nke transformer n'enweghị nsogbu.
Nnyocha ntụgharị
Nyochaa transformer maka akara ọ bụla mebiri emebi. Lelee bushes, ọnụ ọnụ na ihe jụrụ oyi iji gosi na ha dị ọcha na n'ọnọdụ kwesịrị ekwesị.
Ịkwanye Transformer
Jiri kreenu ma ọ bụ bulie elu ka ebuli ihe ngbanwe n'ọnọdụ. Chekwaa ya nke ọma n'osisi ahụ na bolts na nkwado nkwado. Jide n'aka na ọ dị larịị ma kwụsie ike.
Njikọ eletrik
Jikọọ nnukwu {{0}voltaji na obere{1}} voltaji na-eduga dịka ntuziaka onye nrụpụta siri dị. Gbaa mbọ hụ na ọnụ ahịa niile dị ọcha, nke siri ike ma kwadokwa nke ọma.
Nda ala
Tinye onye na-eduzi ala na mkpanaka ala akwadoro ma ọ bụ usoro ntinye ala. Nke a na-enye nchekwa megide mmejọ eletriki ma mee ka ntụkwasị obi sistemu dịkwuo mma.
Nnwale
Mgbe echichi gasịrị, mee ule eletriki ọkọlọtọ dịka nguzogide mkpuchi, polarity, na nlele voltaji. Gosi na transformer na-arụ ọrụ nke ọma tupu inye ume.

Nyocha ikpeazụ
Onye nlekọta ma ọ bụ injinia kwesịrị ime nyocha ikpeazụ. Gwa okwu ọ bụla ma ọ bụ mgbanwe ọ bụla dị mkpa iji zute ụkpụrụ nchekwa na ịdị mma.
Akwụkwọ
Dekọọ nsonaazụ ule niile, nkọwa akụrụngwa yana ndetu nrụnye. Debe akwụkwọ ndị a maka ndozi na ntụnye aka n'ọdịnihu.
50kva pole mounted transformer waiting for testing

 

Ihe nchịkọta dị ọkụ: 50kva okporo osisi n'ịnyịnya transformer, emeputa, soplaya, price, efu