25kva Ogwe Ntugharị Ntugharị-2.4 * 7.2 / 0.12 * 0.24 KV|Canada 2025

25kva Ogwe Ntugharị Ntugharị-2.4 * 7.2 / 0.12 * 0.24 KV|Canada 2025

Obodo nzipu: Canada 2025
Ike: 25kVA
Voltaji: 2.4 * 7.2-0.12 / 0.24kV
Njirimara: Igwe ngbanwe ọkụ abụọ{{0} nwere IFD
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị a pụrụ ịdabere na ya na-emepụta na ndị na-eweta 25kva pole mounted transformer-2.4*7.2/0.12*0.24 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

25kva pole mounted transformer

25kVA pole mounted transformer - dual-voltaji na IFD, emepụtara maka nkesa ike ime obodo nwere ntụkwasị obi, nchekwa na ogologo-

 

 

01 Izugbe

1.1 Nkọwa oru ngo

N'afọ 2025, SCOTECH wetara otu 25kVA otu - oporo etinyere n'usoro ihe ngbanwe maka ọrụ nkesa akụrụngwa Canada.

Ihe oru ngo a gbasoro ụkpụrụ CSA C2.2{2}}06 yana ihe achọrọ nke akụrụngwa Canada. Anyị lebara anya pụrụ iche na nchedo ịwa ahụ, ntụkwasị obi mkpuchi na nchekwa n'èzí-n'ihi na n'ime ime obodo, ị maghị ihe ihu igwe ma ọ bụ anụ ọhịa nwere ike ịtụba gị.

Ejiri ya n'osisi nkesa n'akụkụ ahịrị feeder ime obodo, ihe ngbanwe a na-agbada voltaji ọkara ruo 120/240 V maka ọrụ obibi. Ewubere ya maka netwọkụ nkesa n'elu n'ebe dị ala{3}}, ebe voltaji kwụsiri ike na ịdịtegide gburugburu ebe obibi dị oke mkpa-na ee, nchekwa anụ ọhịa.

Ebe ọ bụ na okporo osisi ndị a na-ekpughere àmụ̀mà, ndị na-agbagharị agbagharị, na mgbe ụfọdụ ụmụ anụmanụ na-achọ ịmata ihe, anyị kwadoro unit ahụ nwere nnukwu ihe njide na-arụ ọrụ - na ndị nche anụ ọhịa. Nhazi a na-eme ka onye na-agbanwe agbanwe bụrụ ntụkwasị obi ogologo oge ma na-enyere aka belata ihe ize ndụ nke nkwụsị, ọbụlagodi na ọnọdụ siri ike.

 

 

 

1.2 Nkọwa nka nka

25kVA okporo osisi n'ịnyịnya ntụgharị nkọwapụta na mpempe akwụkwọ data

Enyere ya
Canada
Afọ
2025
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
CSA C2.2-06
Enyere ike
25KVA
Ugboro ugboro
60HZ
Usoro
Naanị otu
Ụdị oyi
ONAN
Ihe mgbochi mmiri
Mineral Mmanụ
Voltaji nke mbụ
2.4 * 7.2-0.12 / 0.24kV
Voltaji nke abụọ
120/240 V
Otu Vector
Ii6
Ngwa ikuku
Aluminom
Mgbochi
2.02%(±10%)
Ịrụ ọrụ
Karịrị ma ọ bụ haha ​​98.63%
Pịa Changer
NLTC
Enweghị mfu ibu
104 W
Ibu Mfu na Voltaji akwadoro
309 W
Ngwa ngwa
Igwe ngbanwe voltaji abụọ{{0} nwere IFD

 

1.3 Eserese

25 kVA okporo osisi atụkwasịrị ihe ngbanwe na eserese na aha aha

25kva pole mounted transformer drawing 25kva pole mounted transformer nameplate

 

 

02 Nrụpụta

2.1 Ikuku

25kva pole mounted transformer winding

Nhazi eriri igwe: foil LV, waya HV, ngwakọta ọla kọpa na aluminom. Foil na-agbasa ugbu a, na-eme ka okpomọkụ. Waya na-ehulata, na-anọkọ ọnụ. Ọla kọpa- Ngwakọta aluminom na-arụ ọrụ nke ọma yana ọnụ ahịa ya. Na-adịgide adịgide. Na-arụ ọrụ n'okporo ámá ndị mepere emepe, ahịrị ime obodo, ihe ọ bụla ụbọchị na-atụba ya. Kwesịrị ntụkwasị obi, kwụ ọtọ, na-arụ ọrụ ya n'enweghị nsogbu.

 

2.2 IFD

Nke a 25kVA pole mounted transformer nwere ihe nhọrọ Internal Fuse Device (IFD), ahọpụtara iji nyekwuo nchebe maka ntụgharị ntụgharị. IFD na-arụ ọrụ dị ka ihe nchekwa megide mkpirisi ime mkpirisi -mkpirisi mkpirisi ma ọ bụ bufee ibu, na-ewepụ ngalaba ikuku emetụtara na-emetụtaghị sistemu ndị ọzọ. Njirimara a na-eme ka ntụkwasị obi rụọ ọrụ, ọkachasị na netwọk nkesa n'ime ime ma ọ bụ n'ime ime obodo, wee họrọ ya maka ọrụ a iji gboo mkpa nchekwa na arụmọrụ nke onye ahịa.

25kva pole mounted transformer IFD

 

2.3 tank

25kva pole mounted transformer tank

A rụpụtara tankị mmanụ ahụ n'ụlọ ọrụ ogbako tankị nke SCOTECH na-eso usoro mmepụta nke ọma: a na-ebu ụzọ gbutuo efere ígwè ndị ahụ ka ọ ha buru ibu, gbawaa ya, gbadaa, ma tụgharịa ka ọ bụrụ ọdịdị, wee gbanye ya n'ime tank zuru oke. Mgbe ịgbado ọkụ, ndị ọrụ nka anyị ji aka wepụrụ slag, dị ka e gosiri na foto a na-eso ya, a na-edozikwa tankị ahụ site n'igweri na ịgbawa{1}. N'ikpeazụ, a na-etinye ihe mkpuchi ntụ ntụ, na tankị emechara wee nyochaa nke ọma iji hụ na ogologo oge - dị n'èzí, nguzogide corrosion, na ịdị mma zuru oke.

 

2.4 9kV HV onye njide

Iji chekwa 25kVA pole mounted transformer na-arụ ọrụ na sistemu nkesa isi nke 7.2kV, a na-ahọrọ ihe njide klaasị 9 kV ma tinye ya n'akụkụ nke mbụ.

Onye njide na-eme ka ọkụ ọkụ na-erute 30 kV, nke pụtara na mkpuchi nke transformer na-echekwa na ndụ ọrụ ya na-enweta ezigbo agbam ume{1} karịsịa n'ebe ahụ n'osisi ekpughere ebe oke ifufe nwere ike ịdaba.

Ma n'ihi na nrụnye ndị a dị n'èzí, yana anụmanụ{0}nke ọma, ha na-achọ ịmata{1} anyị gbakwunyere ndị nche anụ ọhịa n'obere ọhịa na onye njide n'onwe ya. N'ụzọ dị otú a, ihe ize ndụ nke anụmanụ{3} metụtara mmejọ na-adaba, na transformer na-anọkwa na nchekwa na ntụkwasị obi. Ọ bụ kpọmkwem ụdị nchekwa ị chọrọ maka netwọk nkesa ime obodo na ime obodo.

Surge Arresters Installed on Transformers
Awụnyere ndị njide ịwa ahụ na Transformers
Surge Arrester Drawing
Ihe osise onye njide ịwa ahụ
Surge Arrester Protective Cover
Mkpuchi Nchedo Surge njide

 

 

03 Ọkọlọtọ Ọdịdị Nkesa

25kVA pole mounted transformer distribution Structure Standard

 

Ihe

Nkọwa

Ọnụọgụ

1

Ebipụ, Nkwụsị Ibu

1

2

Fuse

1

3

Onye njide, Polymer, 18 kV, 15.3 kV MCOV (Nha ka voltaji nke mbụ)

1

4

Transformer (Nha na ọkwa akọwapụtara na atụmatụ saịtị)

1

5

Mkpọgide, Stirrup, #6 ruo 3/0

1

6

Mkpọgide, Ahịrị na-ekpo ọkụ, # 8 ruo 2/0

1

7

Njikọ, mkpakọ, H- Kpatụ, #2–6 ACSR ka #1-6 STR

3

8

Bracket, Cutout, Welded, Pole{0}}Anyakwasara, Ogologo 12"

1

9

USB / Waya, dobe ụzọ

9

10

USB, #2, Ọla kọpa, ojii, RW90

9

11

USB, #2, Ọla kọpa, Green, RW90

3

12

Bracket, tank -Onye njide etinyere, 2-1/4" akwụrụ, Ogologo 7-1/2"

1

13

Onye nche anụ ọhịa, Transformer Bushing

1

 

Bolt, Igwe, 3/4" Dia. ( Ogologo dị ka achọrọ), c/w Square Nut

Dị ka achọrọ

 

Ọkụ, Mkpọchi, 3/4" Nọmba, Helical Spring, Galv. CSAG164M

Dị ka achọrọ

 

Ihe washer, Square, Flat, 3/4 "Ọm.

Dị ka achọrọ

 

Bolt, Lag, 1/2" Dia., 4-1/2" Ogologo

1

 

04 Mbukota na njem

4.1 mbukota

25kVA pole mounted transformer packing-1
25kVA pole mounted transformer packing-2

 

4.2 Mbupu

25kVA pole mounted transformer shipping-1
25kVA pole mounted transformer shipping-1

 

Ihe nchịkọta dị ọkụ: 25kva okporo osisi n'ịnyịnya transformer, emeputa, soplaya, price, efu

Zipu ozi