25 KVA Ogwe Ntugharị Ntugharị-13.8 / 0.12 / 0.24 KV|Canada 2025

25 KVA Ogwe Ntugharị Ntugharị-13.8 / 0.12 / 0.24 KV|Canada 2025

Obodo: Canada 2025
Ike: 25 kVA
Voltaji: 13.8-0.12/0.24kV
Njirimara: ya na onye isi njide ịwa ahụ
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị a pụrụ ịdabere na ya na-emepụta na ndị na-eweta 25 kva pole mounted transformer -13.8/0.12/0.24 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

25 kVA pole mounted transformer

Merie Oghere, nyefee Ike. Ntugharị okporo osisi na-adaba adaba.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

25 kVA single phase pole mounted transformer e zigara Canada n'afọ 2025. Akara ikike nke transformer bụ 25 kVA na ONAN jụrụ oyi. The elu voltaji bụ 13.8 kV na ± 2 * 2.5% tapping nso (NLTC), ala voltaji bụ 0,12 / 0,24 kV, ha guzobere a vector otu Ii6.

Nke a bụ 125kV BIL Pole Mounted Transformer nke a pụrụ ịdabere na ya nke ukwuu emebere maka gburugburu ebe na-achọsi ike. Ọkwa mkpuchi ihe mgbakwasị ụkwụ 125kV ya na-enye ụlọ ọrụ{3} na-eduga nchebe megide oke ọkụ na-adịru nwa oge, na-eme ka ọ dabara nke ọma maka àmụmà{{4}ógbè ndị dị n'ụsọ oké osimiri, na ebe ndị ọzọ nwere ihe nchebe siri ike chọrọ. Ngalaba ahụ nwere mmanụ agbasiri ike{6}}sistemụ mkpuchi akwụkwọ yana ihe owuwu mechiri emechi, na-ahụ na ogologo oge- nkwụsi ike nke igwe dielectric dị n'ime yana inye nkwado- n'efu. Ọzọkwa, nrụpụta igwe siri ike ya na njikwa ọkụ dị mma na-ekwe nkwa ịrụ ọrụ ga-adịgide adịgide na ntụkwasị obi n'okpuru ọnọdụ ihu igwe siri ike yana ibu na-agbanwe. Ihe ngbanwe a na-arụ ọrụ dị ka isi ihe maka ịkwalite nkwụghachi nke netwọk ikesa ọkụ n'ime obodo, ime obodo, ogige ụlọ ọrụ mmepụta ihe na ebe ntinye ume ọhụrụ. Ọ na-ebelata nke ọma ihe ize ndụ nke àmụmà{12}} na-akpata ọdịda na ụgwọ ọrụ, na-ebuga ọkụ na-aga n'ihu ma kwụsie ike iji kwụsị{13}} ndị ọrụ.

 

 

 

1.2 Nkọwa nka nka

25 kVA okporo osisi n'ịnyịnya mgbanwe nkọwa ụdị na data mpempe akwụkwọ

Enyere ya
Canada
Afọ
2025
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
CSA C2.2-06
Enyere ike
25 kVA
Ugboro ugboro
60HZ
Usoro
1
Polarity
Ihe mgbakwunye
Ụdị oyi
ONAN
Voltaji nke mbụ
13.8 kV
Voltaji nke abụọ
0.12 / 0.24 kV
Ngwa ikuku
Aluminom
Ntugharị akụkụ
Ii6
Mgbochi
2.1%
Pịa Changer
N/A
Enweghị mfu ibu
0,05 kW
Na Ibu Mfu
0,365 kW

 

1.3 Eserese

25 kVA okporo osisi n'ịnyịnya ihe ngbanwe eserese na nha.

25 kVA pole mounted transformer diagram 25 kVA pole mounted transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

25 kVA pole mounted transformer core

Ogwe mgbanaka SCOTECH - na-anakwere ihe nrụnye amorphous alloy core, bụ nke e ji ultra - dị gịrịgịrị amorphous magnetik nwere usoro atọm nwere nsogbu. Nke a dị elu isi ihe na-ebuga ultra - obere isi ọnwụ{4}} dị nnọọ ala karịa nke nke omenala silicon steel cores - ebe ọ na-ahụ na nnukwu magnetik permeability maka ịrụ ọrụ nke ọma mgbanwe ike. Nrụpụta kọmpat ya dị fechaa ọ bụghị naanị na ọ na-eme ka nrụnye nrụnye dị mfe ({7}}) kamakwa ọ na-akwalite nguzogide corrosion na nkwụsi ike arụmọrụ, na-eme ka ọ dị mma maka netwọk nkesa obodo na ime obodo.

 

2.2 tank

Ogwe SCOTECH {{0} agbakwunyere igwe nrụnye nwere tank nke ejiri igwe anaghị agba nchara arụpụtara site na nnukwu igwe dị mma{1}, mechara ya na isi awọ (Number 70, Munsell notation 5BG7.0/0.4) maka ịchọ mma na nkwụsi ike gburugburu ebe obibi. N'ịnya isi akụkụ kọmpat nke 580*660*1050 mm, ihe owuwu a mechiri emechi nke ọma na-echebe ihe ndị dị n'ime ya pụọ ​​​​na mmiri, uzuzu na mmetọ dị na mpụga, na-eme ka ntụkwasị obi na-arụ ọrụ ogologo oge n'ọnọdụ nkesa obodo na ime obodo.

25 kVA pole mounted transformer tank

 

2.3 Onye isi nchịkwa na-ahụ maka ọrụ

surge arrester boss

Ogwe a- nke a wụnyere ngbanwe nwere onye isi njide ịwa ahụ agbakwunyere, emebere ya maka ịgbago ndị na-ejide ịwa ahụ nke ọma na nchekwa. Emebere ya site na nguzosi ike n'ezi ihe n'usoro yana ndakọrịta na nhazi ihe njide ọkọlọtọ, onye isi a na-enye nkwado n'ịrụ ọrụ a pụrụ ịdabere na ya ma na-eme ka ọ dị ngwa, nrụnye n'efu-. Nhazi ya kachasị mma na-eme ka ntugharị dị irè nke oke ọkụ na-adịru nwa oge, na-echekwa ihe ndị bụ isi nke transformer megide ọkụ eletrik na ịkwalite nchekwa ọrụ grid n'ozuzu ya.

 

Ọdụ ụgbọ elu 2.4 HV

Ogwe a{{0} nkwalitere n'elu ihe nrụnye nwere ikike HV a pụrụ ịdabere na ya, na-egosipụta ọdụ ụgbọ elu H1 (4-ụdị mkpọchi) maka njikọ mpụga na-agbanwe agbanwe yana echekwara, ebe ọdụ ụgbọ mmiri H2 na-ejikọta n'ime tank na tank site na njikọ siri ike-ụdị njikọ. Nhazi ọnụ ọnụ a kachasị mma na-eme ka nnyefe ike kwụsie ike, na-eme ka wiwi saịtị dị mfe, ma na-ebuli ike igwe, na-ebuga arụmọrụ na-agbanwe agbanwe yana nchekwa ọrụ na ngwa netwọkụ nkesa.

HV Terminal

 

2.5 Mgbochi

25 kVA pole mounted transformer grounding

Okporo ígwè{{0}n'enyanye ihe ngbanwe ahụ na-agụnye sistemu ịgbado ala, gụnyere isi ala raara onwe ya nye na ịgbado tankị, nke ejiri eriri mgbado a pụrụ ịdabere na ya na igwe anaghị agba nchara-oghere oghere-ụdị nkwụsị ala. Nhazi a agbakwunyere na-eme ka mwepu nke ọma nke ikuku na-adịghị mma na ụgwọ kwụ ọtọ, na-ebelata ihe egwu eletriki, ma na-akwalite nchekwa ọrụ, ebe nhazi ọnụ ọnụ na-adịgide adịgide na-enyere aka nchekwa, mgbakasị ahụ - njikọ mgbada n'efu na nrụnye netwọkụ nkesa.

 

2.6 Ngwaọrụ enyemaka nrụgide

Ihe ngbanwe ahụ nwere ngwaọrụ enyemaka nrụgide siri ike, emebere ya ka ọ hapụ oke nrụgide dị n'ime n'ihi ọnọdụ arụ ọrụ adịghị mma (dịka ọmụmaatụ, ikpo ọkụ ma ọ bụ ịgba ọkụ). Ihe nchekwa nchekwa a dị oke egwu na-egbochi nrụrụ ma ọ bụ mmebi nke tank, na-echekwa akụkụ nke ngbanwe dị n'ime ma na-ahụ na arụmọrụ arụ ọrụ. Site na ịrụ ọrụ ngwa ngwa{{4} na ịrụ ọrụ na-adịgide adịgide, ọ na-eme ka nchekwa sistemụ na ntụkwasị obi zuru oke na nrụnye netwọkụ nkesa obodo na ime obodo.

Pressure Relief Device

 

2.7 Mba -Onye na-agbanwe mgbata obi ụtọ

No-Excitation Tap Changer

Oghere SCOTECH - agbakwunyere ngbanwe nwere ihe na-agbanwe agbanwe na-adịgide adịgide- excitation tap Changer, e mere ya maka de{2}} ụkpụrụ voltaji na-agba ume iji kwekọọ na ngbanwe grid. N'igosipụta ọnọdụ mgbatụ ziri ezi, nrụpụta igwe siri ike, yana ọrụ enyi na enyi, ọ na-eme ka voltaji mmepụta dị mma{5}} na-eme ka ọ dị mma na-eme ka ihe nrụnye dị ọkụ, na-ahụ na nchekwa ọrụ na nguzosi ike n'ezi ihe. N'ikwekọ n'ụkpụrụ ụlọ ọrụ, akụrụngwa a na-enye arụmọrụ a pụrụ ịdabere na ya, na-enyere aka ịnọgide na-enwe ogo ọkụ ọkụ n'ofe netwọk nkesa obodo na ime obodo.

 

 

03 Nnwale

Oghere SCOTECH - n'enya igwe ngbanwe nke SCOTECH na-enweta ule siri ike na-ekpuchi ntugharị nha na njikọ ọ bụla, nkwenye polarity, enweghị - ibu mfu na nha dị ugbu a na-akpali akpali na voltaji 105% kwadoro, mfu ibu na ule impedance n'ogo ugbu a na voltaji, yana etinyere na butere voltaji na-anagide ule, gbakwunyere{3} ule mgbanwe. Ntụle ndị a zuru oke na-eme ka nrube isi n'ụkpụrụ ụlọ ọrụ, na-akwado arụmọrụ eletriki na iguzosi ike n'ezi ihe, na-ekwe nkwa ntụkwasị obi, ọrụ nchekwa na netwọk nkesa.

25 kVA pole mounted transformer testing
25 kVA pole mounted transformer test

 

 

04 Mbukota na mbupu

25 kVA pole mounted transformer packing
25 kVA pole mounted transformer shipping

 

 

05 Saịtị na nchịkọta

Ogwe SCOTECH {{0}Nrụnye ngbanwe na-ejikọta ihe ndị dị elu{1}si na obere-loss amorphous alloy core na hermetically sealed mild steel tank gaa na ọdụ ụgbọ elu HV siri ike, sistemu ala ala zuru oke, yana atụmatụ nchekwa nchekwa dị ka ngwaọrụ enyemaka nrụgide na onye na-ejide onye na-ahụ maka ịwa ahụ {{3} nlebara anya nke ọma. Emebere ya maka ịrụ ọrụ nke ọma, ịdịte aka na ịdị mfe nke nrụnye, ọ na-ebuga nkesa ike na-agbanwe agbanwe na netwọk obodo na ime obodo, na-etinye ntinye aka SCOTECH maka ịdịmma, ihe ọhụrụ na arụmọrụ ntụkwasị obi maka ngwa grid dị oke mkpa.

25 kVA pole mounted transformer supplier

Ihe nchịkọta dị ọkụ: 25 kVA okporo osisi arịọnụ transformer, emeputa, soplaya, price, na-eri

Zipu ozi