100 kva pole mounted transformer

Ike dị n'osisi, ike dị n'obi - Otu -osisi n'usoro{1}} na-ebunye ihe ngbanwe, na-eme ka ọkụ eletrik pụta ìhè.

 

01 Izugbe

1.1 Ihe ndabere oru ngo

SCOTECH nwere obi ụtọ ịnye igwe nrụnye ọkụ ọkụ- dị mma - nke etinyere n'obere oge maka Ọrụ Ọha Canada. Igwe ngbanwe{3} nke otu nwere ikike nke 100kVA, voltaji nke izizi bụ 7.97/13.8Y yana voltaji nke abụọ bụ 0.12/0.24kV, nke nwere ike gboo mkpa ọkụ eletrik n'ime obodo. The otu akụkụ okporo osisi mounted transformer na-atụgharị voltaji nke okporo n'ime voltaji chọrọ nke usoro ma ọ bụ ibu, na-aghọta nnyefe na nkesa nke eletriki ike. Nnukwu ọrụ{11} nke ngwaahịa a nwere ike nweta mmetụta nchekwa ike dị mma ma belata mmetọ ikuku. Ngwaahịa a dabara adaba maka ụkọ ike na mgbanwe ibu ma sie ike ịrụ ọrụ mmezi kwa ụbọchị na mpaghara. N'ihi na transformer na-anakwere ihe mkpuchi nke ọma, mmanụ mkpuchi na mkpuchi mkpuchi adịghị emerụ site na ikuku, n'ihi ya, ọ nwere ike ịrụ ọrụ na gburugburu ebe iru mmiri, ma bụrụ ngwá ọrụ nkesa dị mma na nnukwu netwọk nkesa na obodo na ime obodo. Igwe ngbanwe nke otu{15} na-adabara nke ọma maka ọkụ ọkụ ime obodo, mpaghara ugwu ugwu, obodo ndị gbasasịrị agbasa, mmepụta ugbo, ọkụ na oriri ọkụ. nwekwara ike iji ụgbọ okporo ígwè, ike obodo ike grid ike -ichekwa mgbanwe ụdị kọlụm nkesa, nwere ike ịbụ otu{18}}phase ọrụ ma ọ bụ atọ otu -phase otu dị ka atọ{20}phase ọrụ.

Ejiri teknụzụ dị elu jiri teknụzụ dị elu mee ihe anyị 100 kVA ma nabata akụrụngwa na akụrụngwa dị elu nke na-ebute ogo a pụrụ ịdabere na ya na ogologo oge ọrụ.

 

 

1.2 Nkọwa nka nka

Ụdị nkọwapụta 100 kVA na mpempe data

Enyere ya
Canada
Afọ
2024
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
IEEE C57.12.20
Enyere ike
100kVA
Ifufe
Aluminom
Polarity
Ihe mgbakwunye
Ugboro ugboro
60HZ
Usoro
1
Ụdị oyi
ONAN
Voltaji nke mbụ
7.97/13.8Y kV
Igwe ọkụ nke isi abụọ
Mba
Voltaji nke abụọ
0.24/0.12 kV
Otu Vector
Ii0
Mgbochi
2.2%
Pịa Changer
NLTC
Mmiri mmiri mmiri
Mineral Mmanụ
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
0.068kW
Na Ọnwụ Ebu
0.98kW
Ndidi
10% NLL, 6% Mkpokọta mfu
Ngwa ngwa
Nhazi ọkọlọtọ

 

1.3 Eserese

100 kVA okporo osisi agbakwunyere ihe eserese eserese na nha.

100 kva pole mounted transformer diagram 100 kva pole mounted transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

A na-egosipụtakarị uru ndị dị na eriri igwe transformer na arụmọrụ ya dị oke mma yana ikike nnyefe ike dị mma. A na-emeziwanye arụmọrụ nke transformer n'ihi na usoro ikuku na-ebelata ikuku ikuku na ọnwụ. Nhazi a na-enyere aka belata mkpọtụ na ịma jijiji ma na-eme ka arụmọrụ zuru ezu. Coil core nwere ike ibelata mfu eddy ugbu a n'ihi nkesa na-agbanwe agbanwe ya. Na mgbakwunye, usoro ntụgharị ahụ na-enye usoro siri ike karị, na-eme ka ike arụ ọrụ na ịdịte aka, yana ADAPTS ruo oke okpomọkụ na gburugburu iru mmiri. Igwe eriri igwe na-ebelata mkpọtụ na ịma jijiji na-arụ ọrụ, na-eme ka akụrụngwa kwụsie ike, nwee ike ime mgbanwe na ebe ọrụ dị iche iche, yana ịgbatị ndụ ọrụ nke akụrụngwa.

100 kva pole mounted transformer iron core

 

2.2 Ikuku

Dị ka akụkụ nke winding, obere -voltaji foil winding nwere ike ichebe oghere electromagnetic nke ikuku ikuku dị elu{1}, si otú a na-ebelata mmetụta nke nnyonye anya electromagnetic (EMI). Mgbe ihe ngbanwe na-ekerịta oghere na ngwaọrụ eletrọnịkị ndị ọzọ, ọ nwere ike ibelata nnyonye anya n'etiti ngwaọrụ eletrọnịkị ma melite ndakọrịta elektrọnik nke sistemu niile. Dị ka akụkụ nke winding, obere -voltaji foil winding nwere ike ichebe oghere electromagnetic nke ikuku dị elu-voltaji, si otú a na-ebelata mmetụta nke nnyonye anya electromagnetic (EMI). Mgbe ihe ngbanwe na-ekerịta oghere na ngwaọrụ eletrọnịkị ndị ọzọ, ọ nwere ike ibelata nnyonye anya n'etiti ngwaọrụ eletrọnịkị ma melite ndakọrịta elektrọnik nke sistemu niile. N'ihi njiri mara nhazi nke ikuku ikuku dị ala-voltaji, ọ nwere ike gbasasịa okpomoku dị n'ime obodo nke mmejọ sekit dị mkpụmkpụ na-ebute, belata ohere nke mmetụta ozugbo nke obere sekit dị ugbu a na ikuku ikuku, wee kwalite nchekwa na ntụkwasị obi nke transformer. Nhazi ezi uche dị na{10}voltaji na elu{11}}voltaji winding chepụta nwere ike ibelata ihe nhụpụta ndọta nke ọma wee kwalite arụmọrụ ike na arụmọrụ nke transformer. Site n'ịkwalite nhazi n'etiti windings, enwere ike nweta njikọ flux ka mma, si otú ahụ na-eme ka arụmọrụ nke transformer dịkwuo mma.

 

2.3 tank

100 kva pole mounted transformer oil tank

Dị ka ihe osise eserese si kwuo, a na-eji ngwá ọrụ ndị dị ka igwe na-egbutu plasma, igwe laser ma ọ bụ mma mmiri, na-egbutu ihe mpempe akwụkwọ metal n'ime akụkụ dị iche iche nke tank ahụ, gụnyere efere ala nke tank ahụ, mgbidi akụkụ nke cylinder ahụ, mkpuchi elu, wdg. A na-ejikọta akụkụ nke tankị ahụ nke ọma site na iji usoro dị ka gas na-agbado ọkụ (MIG welding) ma ọ bụ arc welding, na welds kwesịrị ịdị n'otu ma dị nro ma nwee ezigbo akara. Mgbe ịgbado ọkụ, elu nke tank kwesịrị ka emetọ ya iji wepụ welding slag, oxide oyi akwa na mmanụ. A na-efesa ihe mkpuchi mgbochi{{4} na mpụga tank ahụ iji gbochie nrụrụ nke mmetụta gburugburu ebe obibi na-eme kwa ụbọchị. A pụkwara iji mgbochi- corrosion agwọ mgbidi dị n'ime ahụ iji mee ka ndụ mmanụ dị n'ime ya dịkwuo elu.

 

2.4 Mgbakọ ikpeazụ

100 kva pole mounted transformer assembly
100 kva single phase pole mounted transformer assembly

 

 

03 Nnwale

Mba.

Nwale ihe

Nkeji

Nnabata

Ụkpụrụ

Ụkpụrụ ndị atụtara

Mmechi

1

Ntụle Nguzogide

%

/

/

Gafe

2

Nlele oke

%

Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha ​​na 0.5%

Akara njikọ: ii6

-0.02

Gafe

3

nkeji -nnwale mmekọ

/

Ihe mgbakwunye

Ihe mgbakwunye

Gafe

4

Ọ dịghị - ibu mfu na mkpali ugbu a

%

kW

t:85 ogo

I0:  nye uru a tụrụ atụ

P0: nye uru a tụrụ atụ

nnabata maka enweghị ibu ibu bụ +10%

0.39(100%)

1.00(105%)

0.056(100%)

0.067(105%)

Gafe

5

Ibu na-efunahụ voltaji impedance na arụmọrụ

%

kW

kW

t:85 ogo

Z%: uru tụrụ

Pk: uru tụrụ

Pt: uru tụrụ

Nkwenye maka impedance bụ ± 10%

Nkwenye maka mkpokọta mfu ibu bụ +6%

2.20

0.868

0.927

99.49

Gafe

合格

6

Nnwale voltaji etinyere

kV

HV: 34kV 60s

LV: 10kV 60s

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

7

Nnwale Nkwụghachi Voltaji butere

kV

Voltage etinyere (KV): 15.94

Ogologo oge: 40

Ugboro (HZ): 150

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

8

Ule ntapu

kPa

Ntinye nrụgide: 20kPA

Ogologo oge: 12h

Enweghị ntapu na mba

Mmebi

Gafe

9

Ntụle Nguzogide mkpuchi

HV&LV n'ala:

90.7

/

HV -LV gaa n'ala

16.4

LV-HV gaa n'ala

16.9

10

Nnwale Dielectric mmanụ

kV

Karịrị ma ọ bụ hà nhata 45

55.38

Gafe

11

Nnwale mkpali ọkụ

kV

ife zuru oke, Ọkara ife

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

 

100 kva pole mounted transformer testing
100 kva single phase pole mounted transformer test

 

 

04 Mbukota na mbupu

4.1 mbukota

1. Tinye desiccant n'ime ngwungwu transformer, wee kpochaa ya ka ịzena nchara dị ka o kwere mee.

2. Nke ọ bụla a na-eji mkpagharị ọkụ na-arụ ọrụ na-ebu ibu arụ ọrụ, na-edozi na nkwado osisi;

3. Nke ọ bụla nwere ihe mgbawa T{1}

4. Isi osisi siri ike (nchara chanel chọrọ)

5. Tinye akwụkwọ nlele leakage na tray transformer

6. Buru ụzọ mechie akpa foil tin, hapụ oghere, jiri ihe na-ekpocha ọkụ na-agbapụta, ma mechaa wepụ oghere ahụ na ihe mkpuchi.

7. A na-echekwa akụkụ anọ dị n'akụkụ transformer site na nchebe nkuku wee merụọ ihe nkiri ahụ

8. Fesa njirimara forklift, etiti njirimara ike ndọda

100 kva pole mounted transformer packing

 

4.2 Mbupu

100 kva pole mounted transformer shipping

1. Nbudata na nbudata: A na-eji ngwá ọrụ na-ebuli elu na-eme ka ọ bụrụ na ọ dịghị ihe ọzọ na-arụ ọrụ n'oge a na-ebufe ihe ntụgharị.

2. Edoziri: N'oge njem, ọ dị mkpa ka a dozie ihe ntụgharị ahụ nke ọma iji gbochie nkwụsị ma ọ bụ nkukota, na-akpata mmebi ígwè.

3. Nchedo: Ọ dị mkpa ka e mee ihe iji kpuchido akụkụ mkpuchi nke transformer na ihe dị n'èzí iji gbochie mmetọ ma ọ bụ mmebi.

 

 

05 Saịtị na nchịkọta

Daalụ maka mmasị gị na Single {{0}Phase Pole-Mounted Transformer! Site na arụmọrụ dị elu, nkwụsi ike, na ịdịte aka, a na-eji ngwaahịa a eme ihe n'ọtụtụ ebe dị iche iche na-ebufe ike na nkesa, na-enye ngwọta ike a pụrụ ịdabere na ya maka ndị ahịa anyị. Anyị na-ebute mkpa ndị ahịa ụzọ mgbe niile, na-elekwasị anya na teknụzụ ọhụrụ na nkwalite ịdịmma, ma na-agba mbọ ịnye ọrụ dị elu na ahụmịhe ngwaahịa. Maka ozi ndị ọzọ ma ọ bụ nkwado, biko nweere onwe gị ịkpọtụrụ anyị!

100 kva pole mounted transformers

 

Ihe nchịkọta dị ọkụ: 100 kva okporo osisi arịọnụ transformer, emeputa, soplaya, price, efu

Zipu ozi