50 kVA Utility Pole Transformers-34.5 / 0.12 * 0.24 kV|Canada 2024

50 kVA Utility Pole Transformers-34.5 / 0.12 * 0.24 kV|Canada 2024

Obodo: Canada 2024
Ike: 50kVA
Voltaji: 34.5/0.24kV
Njirimara: ya na OCTC
Zipu ozi

 

 

utility pole transformers

Nfefe pụrụiche, ọkụ ọkụ ziri ezi – Otu ọnụ ala-obere ogologo- na-etinye ihe ngbanwe na-eme ka ndụ ka mma.

 

01 Izugbe

1.1 Ihe ndabere oru ngo

Nke a 50kVA otu akụkụ okporo osisi mounted transformer na-exported na Canada na July, 2024. The gosiri ike nke akọrọ ụdị transformer bụ 50 kVA, isi voltaji bụ 34.5 kV na nke abụọ voltaji bụ 0.12/0.24 kV. The transformers emepụtara anyị ụlọ ọrụ na-e na elu arụmọrụ na ike na-azọpụta akpọrepu ígwè isi Ọdịdị. The ígwè isi ihe na-mere nke elu mma oyi akpọrepu ọka gbakwasara silikoni ígwè mpempe akwụkwọ mkpuchi nke ịnweta oxide. Site n'ịchịkwa usoro ịkpụ na ịgbakọta nke mpempe akwụkwọ silicon steel, a na-ebelata ọkwa nhụsianya nke transformer na enweghị - ibu dị ugbu a na ọkwa mkpọtụ. Na mgbakwunye, teknụzụ ikuku pụrụ iche nke transformer na-emeziwanye nguzogide àmụmà na mkpirisi nguzogide gburugburu{{11}. A na-ejikarị ya na netwọk nkesa nke ime obodo, mmepụta ugbo na ọkụ ọkụ na nkesa ụlọ obodo.

Anyị na-ahụ na nke ọ bụla n'ime ngalaba anyị ewepụtara enwetala ule nnabata zuru oke. Anyị na-enye otu ọrụ ngwungwu {{1} site na nyocha, nhota okwu, nrụpụta, nrụnye, inye ọrụ, ọzụzụ maka ọrụ ire ere, ngwaahịa anyị na-arụ ọrụ ugbu a karịa mpaghara 50 n'ụwa. Anyị bu n'obi ịbụ onye na-ebubata gị ntụkwasị obi yana onye mmekọ kacha mma na azụmaahịa!

 

1.2 Nkọwa nka nka

50 kVA otu ogwe osisi etinyere nkọwapụta ntụgharị na mpempe data

Enyere ya
Canada
Afọ
2024
Nlereanya
50kVA-34.5-0.12 / 0.24kV
Ụdị
Otu akụkụ okporo osisi etinyere ngbanwe
Ọkọlọtọ
IEEE C57.12.20
Enyere ike
50kVA
Ugboro ugboro
60HZ
Usoro
Naanị otu
Ụdị oyi
ONAN
Voltaji nke mbụ
34.5 kV
Voltaji nke abụọ
0.12 / 0.24 kV
Ngwa ikuku
Aluminom
Polarity
Mwepu
Mgbochi
2.5%
Ndidi
±7.5%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Mmiri mmiri mmiri
Mineral mmanụ
Enweghị mfu ibu
0.112KW
Na Ọnwụ Ebu
0.5KW
Ngwa ngwa
Nhazi ọkọlọtọ

 

1.3 Eserese

Ihe osise 50 kVA nke etinyere ihe ngbanwe ihe osise na nha.

3 phase to single phase transformer wiring diagram pole mounted transformer drawing

 

 

02 Nrụpụta

2.1 Isi

N'ihi na eriri eriri isi na-emerụ n'akụkụ kasị mma magnetik direction nke gbakwasara silicon ígwè mpempe akwụkwọ, ọ n'ụzọ zuru ezu na-enye zuru ezu play ka elu arụmọrụ nke oriented silicon ígwè mpempe akwụkwọ, magnetik flux direction bụ kpamkpam kwekọrọ na nghazi nke silicon ígwè mpempe akwụkwọ, ike ibu ibu siri ike, na magnetik sekit distortion dị obere, ya mere ọ dịghị - ibu ọnwụ na enweghị ugbu a bụ obere ígwè laminated (The isi iyi ga-laminated) ndọta sekit ndọta n'ihi nkwonkwo laminated).

amorphous steel core transformer

 

2.2 Ikuku

transformers primary and secondary coils

- Obere voltaji na-ekufe ya na waya eriri eriri kechie ezigbo mma,

- A na-emerụ ikuku voltaji dị elu yana waya aluminom dị elu-dị mma polyurethane{2}}

- Insulation interlayer na-eji akwụkwọ dotting ejikọta eriri igwe ahụ n'ime nkeji edoziri nke nwere ezigbo mkpuchi mkpuchi

- Usoro ihe ngbanwe ahụ bụ nke a pụrụ ịdabere na ya n'oge a na-arụ ọrụ na njem

 

2.3 tank

- Igwe ncha laser Mitsubishi nke Japan na ịkụ ọkpọ CNC, ibelata, mpịachi na akụrụngwa ndị ọzọ iji hụ na nhazi ya ziri ezi.

- ABB robot akpaka ịgbado ọkụ, nchọpụta laser, zere ntapu, ngafe ọnụego 99.99998%

- Ọgwụgwọ ịgba electrostatic, afọ 50 anaghị ewepụ agba (ihe mkpuchi corrosion na-eguzogide n'ime 100h, ike siri ike karịa ma ọ bụ nhata 0.4)

- Ụdị cylinder nke ejiri onwe ya mechiri emechi nke ọma na valvụ enyemaka nrụgide (ANSI nkọwapụta)

- Ọkọlọtọ NEMA hanger braket (nkeji ọ bụla gụnyere efere nkwado okporo osisi)

- Ọdịdị mechiri emechi, ndozi{1} n'efu, ndụ ọrụ nkịtị karịrị afọ 30

ABB transformer

 

2.4 Mgbakọ ikpeazụ

closed core transformer
pole transformer near me

 

 

03 Nnwale

1. Ratio na njikọ niile wee pịa ọnọdụ

2. Nnwale polarity

3. Mba{1}} ibu mfu na voltaji 100% agbaziri ruo ogo 85

4. Na-akpali akpali ugbu a na 100% gosiri voltaji

5. Ibu efu efu na impedance na akara ugbu a gbaziri na 85 ogo

6. Ntinye voltaji

7. Voltage na-ebute

8. Ntugharị tankị nke transformer{1}}nnwale nchọpụta.

 

Nsonaazụ ule

Mba.

Nwale ihe

Nkeji

Nnabata

Ụkpụrụ

Ụkpụrụ ndị atụtara

Mmechi

1

Ntụle Nguzogide

/

/

/

Gafe

2

Nlele oke

/

Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha ​​0.5%

Akara njikọ: ii0

-0.02

Gafe

3

Nnwale polarity

/

Mwepu

Mwepu

Gafe

4

Ọ dịghị - ibu mfu na mkpali ugbu a

%

kW

I0 : nye uru a tụrụ atụ

P0: nye uru a tụrụ atụ

nnabata maka enweghị ibu ibu bụ ± 15%

0.32

0.112

Gafe

5

Mfu ibu, voltaji impedance, mfu zuru oke na arụmọrụ

/

kW

kW

t:85 ogo

Z%: uru tụrụ

Pk: uru tụrụ

Pt: uru tụrụ

nnabata maka impedance bụ ± 10%

nnabata maka ngụkọta ibu ọnwụ bụ ± 8%

2.60

0.488

0.600

99.12

Gafe

6

Nnwale voltaji etinyere

/

HV: 70KV 60S

LV: 10kV 60s

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

7

Nnwale Nkwụghachi Voltaji butere

/

Voltaji etinyere (KV): 69

Ogologo oge (s): 48

Ugboro (HZ): 150

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

8

Ntụle Nguzogide mkpuchi

GΩ

HV -LV n'ala:

LV-HV gaa n'ala:

HV&LV n'ala:

59.3

57.7

56.4

/

9

Ule ntapu

/

Ntinye nrụgide: 20kPA

Ogologo oge: 12h

Enweghị ntapu na mba

Mmebi

Gafe

10

Nnwale mmanụ

kV,

mg/kg,

%,

mg/kg,

Ike Dielectric;

Ọdịnaya Ọdịnaya;

Ihe nbipu;

Nyocha nke Furan;

Nyocha chromatography gas

50.8

9.6

0.00437

0.03

/

Gafe

 

utility pole transformers testing

 

 

04 Mbukota na mbupu

packing for utility pole transformers shipping for utility pole transformers
   
 

 

05 Saịtị na nchịkọta

Daalụ maka mmasị i nwere n'ebe a na-enugharị {{0}phase pole- nke a na-agbanye n'elu igwe mgbanaka! Site na arụmọrụ ya, nkwụsi ike, na ịdịte aka ya, ngwaahịa a na-enye nkwado a pụrụ ịdabere na ya maka nnyefe ike ma na-eje ozi dị ka isi ihe na usoro ike. Anyị na-agbaso ụkpụrụ nke ịdị mma mbụ na mkpa ndị ahịa, na-aga n'ihu na-emepe emepe iji wepụta ngwọta na ọrụ ka mma. Anyị na-atụ anya ka gị na gị rụọ ọrụ iji mepụta ọdịnihu mara mma ọnụ!

eaton pole mounted transformers

 

Ihe nchịkọta dị ọkụ: Utility okporo osisi transformers, onye nrụpụta, soplaya, price, efu