6 MVA Igwe ọkụ eletrik na-eme mgbanwe-33 / 2.2 kV|South Africa 2025
Ike: 6MVA
Voltaji: 33/2.2kV
Njirimara: Igwe ọkụ na-ekpo ọkụ- itinye galvanized radiator

MVA mmanụ 6 nke ọma na ntụkwasị obi-emikpu maka sistemu inverter, na-ebuga voltaji dị nchebe, mfu dị ala, yana arụmọrụ na-adịgide adịgide na gburugburu mpụga South Africa.
01 Izugbe
1.1 Nkọwa oru ngo
Mmanụ 6MVA a -emikpuike transformerE zigara South Africa na 2024 maka ojiji na sistemụ inverter. Ihe ntụgharị ọkụ eletrik 6 MVA nwere ikike nke 6000 kVA, voltaji bụ isi nke 33 kV, na voltaji nke abụọ nke 2.2 kV. Ọ na-agbaso ụkpụrụ IEC 60076 nke ọma
Ọ bụ ezie na ndị inverters nwere ike ịtụgharị ike DC ka ọ bụrụ ike AC, voltaji grid na-adịkarị elu karịa onye inverter nwere ike idi. Iji hụ na arụ ọrụ nke sistemu adịghị mma, onye ngbanwe anyị na-agbadata voltaji dị elu nke grid (33kV) ruo 2.2 kV nke ndị inverter na-anabata. Ihe ngbanwe ahụ na-enyekwa ikewapụ ọkụ eletrik, nkwekọ ekwekọ, na nchedo sistemu, na-ahụ maka ọrụ nchekwa na kwụsiri ike n'etiti ihe ntụgharị na grid.
Ọ na-anya isi arụmọrụ dị elu. Mba - mfu efu dị obere ka 6.2 kW, na mfu efu dị obere ka 39 kW, na-ebelata oriri ume na ụgwọ ọrụ. Ihe mgbochi 7% na-eme ka voltaji kwụsie ike n'ọnọdụ dị mkpirikpi{6}, na ikuku ọla kọpa na-enye ezigbo conductivity, na-echebe ma inverter na grid.
Igwe ọkụ eletrik 6 MVA jupụtara na PCB{1}} mmanụ mkpuchi ịnweta ịnweta n'efu, na-akwalite nchekwa gburugburu ebe obibi. Sistemu jụrụ oyi na-eji ikuku jụrụ oyi ma nwee igwe ọkụ - itinye galvanized radiator. Nke a na-eme ka mgbasa ọkụ dị mma na nguzogide ihu igwe siri ike, na-eme ka ha dị mma maka gburugburu mpụga South Africa.
Ngwa ngwa ngwa gụnyere ihe nleba ọkwa mmanụ, valve enyemaka nrụgide, ngwaọrụ nlekota mmanụ na ikuku ikuku, Buchholz relay, na respirator, na-eme ka ọrụ nchekwa na kwụsie ike na ịgbatị ndụ akụrụngwa. Site na arụmọrụ ya dị elu, mfu dị ala, yana imewe siri ike, mmanụ 6MVA a{2}} ihe ngbanwe ike imikpu abụghị naanị ezigbo nhọrọ maka grid inverter{3} ejikọrọ, mana ọ bụkwa isi akụrụngwa ntụkwasị obi maka ọrụ ike ike ọhụrụ.
1.2 Nkọwa nka nka
Nkọwapụta ọkụ eletrik 6MVA na mpempe data
|
Enyere ya
South Africa
|
|
Afọ
2024
|
|
Ụdị
Mgbanwe ike na-emikpu mmanụ
|
|
Ọkọlọtọ
IEC 60076
|
|
Enyere ike
6MVA
|
|
Ugboro ugboro
50HZ
|
|
Usoro
Atọ
|
|
Ụdị oyi
ONAN
|
|
Voltaji nke mbụ
33KV
|
|
Voltaji nke abụọ
2.2 KV
|
|
Ngwa ikuku
Ọla kọpa
|
|
Ihe oyi oyi
PCB free transformer ịnweta mmanụ
|
|
Otu Vector
Dyn11
|
|
Mgbochi
7 %
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
± 2*3% @ akụkụ mbụ
|
|
Enweghị mfu ibu
6.2KW
|
|
Na Ibu Mfu
39KW
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
1.3 Eserese
Ihe ntụgharị ọkụ eletrik 6MVA na-ese na mpempe aha
![]() |
![]() |
02 Nrụpụta
2.1 Isi
Anyị na-agbaso ihe osise, ụkpụrụ, na usoro nrụpụta maka usoro ọ bụla, na-agba mbọ hụ na mgbakọ bụ isi, njikọ echekwabara nke akụkụ ndị dị ndụ na ntọala ntụkwasị obi. Site na njikwa siri ike a, cores ígwè anyị na-enweta mfu dị ala, mbelata mkpọtụ, ike mkpuchi dị elu, yana nkwụsi ike dị mkpụmkpụ{1}, na-ahụ na ogologo oge{2}} na-arụ ọrụ mgbanwe mgbanwe.

2.2 Ikuku

Igwe ikuku ikuku bụ usoro dị egwu. Anyị na-eji ọla kọpa mara mma{{1}, na-ahụ na arụmọrụ dị mma na ike igwe. N'oge ikuku, anyị na-edobe mkpuchi otu, oghere na-agbanwe agbanwe, yana akwa akwa dị mma iji gbochie ebe na-ekpo ọkụ na ọdịda mkpuchi. Mgbe ikuku gachara, a na-akpụzi eriri igwe, chekwaa ma kpochie ya, na-eji nyocha dị mma, na-ahụ nkwụsi ike n'okpuru nrụgide mkpirisi mkpirisi, thermal na eletriki ka ọ na-emezu ihe njikọ Dyn11 chọrọ.
2.3 tank
Efere -ụdị radiator na-ekpo ọkụ{1}} itinye galvanized ma na-ese na C12 ube oyibo green. N'oge tank mmanụ na-agbanwe ike na mmepụta radiator, a na-eji nlezianya gbuo welds niile iji hụ na ọ dịghị ihe ọ bụla, nke nyocha nke ikuku na 30 kPa kwadoro maka awa 8. A na-agwọta elu ime na mpụta iji gbochie mmebi, na-ekwe nkwa ogologo oge - na mwepu okpomọkụ a pụrụ ịdabere na ya na ọrụ.


2.4 Mgbakọ ikpeazụ

Mgbe a gbakọtara isi ihe ntụgharị na windings, a na-etinye unit ahụ n'ime ụlọ ihicha. Ozugbo akpọnwụchara, a na-ebuli ya ma tinye ya na tank mmanụ. Ihe ngbanwe a nwere ngwa ngwa zuru oke, gụnyere efere{2}}ụdị radiator, ihe ngosi ọkwa mmanụ, valve enyemaka nrụgide, ihe ngosi okpomọkụ mmanụ, Buchholz relay, nchekwa mmanụ, iku ume, enweghị- ihe na-agbanwe mgbata, na ihe ngosi okpomọkụ ikuku. A na-etinye ngwa niile dị ka ihe nrụpụta siri ike anyị chọrọ, yana wiwi dị mma na ahaziri ahazi. Mgbe ntinye ngwa ngwa, a na-emecha usoro mgbakọ ahụ na ntinye mmanụ na mkpuchi, njikọ eletrik na ule, na nyocha nke ọdịdị na akara.
03 Nnwale
Ọkọlọtọ nnwale
IEC 60076 -1-2011, Ndị na-agbanwe ọkụ - Akụkụ 1: Ozuruọnụ
IEC 60076 -3-2013, Ndị na-eme mgbanwe ike-akụkụ 3: ọkwa mkpuchi, ule dielectric na mkpochapụ mpụga na ikuku.
IEC 60076 -7{3}}2018, Power Transformers{4}} Nkebi nke 7 Ntugharị nbinye ọkụ maka ndị na-eme mgbanwe ọkụ na-emikpu mmanụ.


Nnwale oge niile
1. Nleta nke gbazere gasses na dielectric mmiri mmiri si onye ọ bụla dị iche iche mmanụ ngalaba ma e wezụga diverter mgba ọkụ ngalaba.
2. Ntụle nke Voltage Ratio na nlele nke nchụpụ oge
3. Ntụle nke iguzogide ikuku
4. Nleta nke DC mkpuchi mkpuchi n'etiti ikuku ọ bụla na-aga n'ụwa na n'etiti ikuku.
5. Nnwale voltaji etinyere
6. Nleta nke Mba -Ibu ibu na nke dị ugbu a
7. Nnwale voltaji butere
8. Nleta nke Mkpirisi Mkpebi Mkpebi na Mfu ibu
9. Nnwale ntapu site na nrụgide maka mmiri mmiri{1}}Mgbanwe imikpu
Mgbe ule a na-eme ngwa ngwa nke ngwaahịa a gbasoro ihe achọrọ nke IEC 60076-1-2011, IEC 60076-3-2013, IEC 60076-7-2018 ọkọlọtọ na ngwaahịa ahụ tozuru oke. Mmechi: tozuru oke, ikike ịhapụ ụlọ ọrụ mmepụta ihe.
04 Mbukota na mbupu
4.1 mbukota



1. Mgbe nyochachara ụlọ ọrụ, wepụ mmanụ (ma ọ bụ hapụ obere ego), kpoo ime ụlọ, jupụta na ikuku akọrọ ma ọ bụ nitrogen, ma nọgide na-enwe obere nrụgide dị mma.
2. Wụnye ihe nrịbama nrụgide na valve enyemaka iji gbochie oke nrụgide.
3. Wepu ngwa (radiators, conservator mmanụ, gas relay, ọkpọkọ) na mkpọ iche iche.
4. Mechie flanges niile na gaskets nke abụọ na mechie bolts.
5. Tinye ihe nchebe nkuku ma kechie unit ahụ na ihe nkiri nchebe.
6. Kpokọta ngwa ndị a gbasasịrị na igwe nkuku na plywood; debe isi ahu iferi.
7. Tinye ihe ngbanwe n'ime igwe igwe -frame osisi crate; tinye ihe nlekota ujo ma ọ bụrụ na achọrọ ya.
8. Jiri ndụdụ forklift na etiti- akara ike ndọda kaa igbe ahụ.
9. Jiri mmiri mmiri kpuchie akpa ahụ{1}.
4.2 Mbupu

Tupu ibunye, tụọ nha na ịdị arọ nke transformer, wee hazie ụzọ ga-ezere mgbochi ịdị elu, obosara na ịdị arọ. Jiri obere -akwa ma ọ bụ gwongworo pụrụiche nwere ikike zuru oke.
Kwado etiti nke ike ndọda nke transformer na ụgbọ ala. Jiri nchara ọwa na ụzọ nkwụnye kwesịrị ekwesị iji dobe isi na gwongworo ahụ, ma ọ bụrụ na enyere ya ikike. Chekwaa ihe ngbanwe ahụ na èbè ma ọ bụ agbụ site na oghere ụgbọ njem ahapụtara, na-ezere ihe ndị na-emebi emebi dị ka radiators na bushes. Kpochie ihe ndị dị n'ime ma mechie ọnụ ụzọ niile.
Debe ọsọ na-erughị ma ọ bụ ha nhata 60 km / h wee tilt Ihe na-erughị ma ọ bụ ha nhata ogo 15 n'oge njem. Zere mmegharị mberede na ịma jijiji siri ike. Kenye ndị njem ka ịlele njide na kwụsị njem n'oge ihu igwe siri ike.
Mgbe ị na-ebuli elu, debe akụkụ eriri na-erughị ogo 60 ma ọ bụ ha nhata. Jiri ogwe mgbasa ozi ma ọ dị mkpa. Na-ebuli elu mgbe niile, na maka nkeji na-enweghị elu, jiri mkpanaka ebuli elu ala.
05 Saịtị na nchịkọta
Site na nrụpụta nke ọma, ngwa{0} dị elu yana ụkpụrụ mgbakọ siri ike, 6MVA ammanụ - ihe ngbanwe ike imikpuna-ewepụta arụmọrụ a pụrụ ịdabere na ya, ịrụ ọrụ nke ọma na ogologo- na-adịgide adịgide. Nkọwa ọ bụla, site na isi na windings ruo na tank na ngwa, ka emebere iji hụ na arụ ọrụ dị mma yana kwụsie ike na grid inverter{2}} sistemu ejikọrọ n'ofe South Africa.

Ihe nchịkọta dị ọkụ: eletriki ike transformers, emeputa, soplaya, price, na-eri
You Might Also Like
15 MVA Nzọụkwụ Up Power Transformer-4.16 / 69 kV|Guy...
6 MVA Atọ Atọ Ike Ntugharị-33 / 6.6 kV|South Africa ...
3000 kVA omenala ndị na-agbanwe ike-33/11 kV|South A...
3150 kVA Transformer Na Sistemụ Ike-0.4 / 6.6 kV|Sou...
10 MVA Main Power Transformer-33/33 kV|South Africa ...
8 MVA Obere ike ntụgharị-33/33 kV|Zimbabwe 2024
Zipu ozi