8 MVA Obere ike ntụgharị-33/33 kV|Zimbabwe 2024
Ike: 8MVA
Voltaji: 33/33kV
Njirimara: ya na OLTC

1.1 Ihe ndabere oru ngo
8 MVA auto transformer ka ebugara South Africa na 2022.
The gosiri ike nke mmanụ immersed transformer bụ 8000 KVA na ONAF jụrụ, isi voltaji bụ 33 kV na ± 10 * 1.5% tapping nso (OLTC), nke abụọ voltaji bụ 33 kV, ha guzobere vector otu YNa0. Igwe ikuku -voltaji (HV) dị elu bụ kpakpando{7} jikọtara ya na nnọpụiche (Y). ebe a enweghị ntughari oge n'etiti ikuku HV na LV (nke "0 na-egosi"). Na-enye ohere maka mgbanwe voltaji n'akụkụ oke voltaji{11} na-akwụsịghị ibu ahụ. Na-akwụ ụgwọ maka mgbanwe voltaji na grid ma ọ bụ akụkụ ibu. Ike igwe dị elu na ọkụ eletrik na-eme ka ọ dị ogologo{14}} ịrụ ọrụ na obere oge. Na ọnọdụ jụrụ oyi (ONAN), transformer nwere ike ịrụ ọrụ n'obere ikike ya zuru oke. Na ọnọdụ ONAF, mmanye ikuku jụrụ oyi na-enyere onye ntụgharị aka iru ikike ibu zuru oke (80MVA).
1.2 Nkọwa nka nka
8 MVA ike transformer nkọwa na mpempe akwụkwọ data
|
Enyere ya
South Africa
|
|
Afọ
2022
|
|
Nlereanya
OSFZ-8 MVA-33/33 KV
|
|
Ụdị
Mgbanwe ike na-emikpu mmanụ
|
|
Ọkọlọtọ
IEC 60076
|
|
Enyere ike
8MVA
|
|
Ugboro ugboro
50HZ
|
|
Usoro
Atọ
|
|
Ụdị oyi
ONAF
|
|
Voltaji nke mbụ
33KV
|
|
Voltaji nke abụọ
33KV
|
|
Ngwa ikuku
Ọla kọpa
|
|
Otu Vector
YNa0
|
|
Mgbochi
0.98%
|
|
Pịa Changer
OLTC
|
|
Ọkụ aka
±10*1.5%
|
|
Enweghị mfu ibu
2.5KW
|
|
Na Ibu Mfu
16KW
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
|
Okwu
N/A
|
1.3 Eserese
8 MVA ike mgbanwe eserese eserese na nha.

02 Nrụpụta
2.1 Isi
Isi ihe mejupụtara ya bụ ọtụtụ mpempe akwụkwọ nchara silicon stacked, jikọtara ya na eriri na eriri iji kwado nkwụsi ike nhazi. Igwe na-acha uhie uhie na-enye nkwado na ndozi, na-ejikọta akụkụ ndị a kwadoro na elu na ala. Akụkụ etiti nke isi na-eji ọtụtụ ihe mkpuchi mkpuchi iji belata mfu efu ugbu a. Nhazi zuru oke siri ike, yana ọgwụgwọ nchebe elu, na-eme ka ọ dị mma maka gburugburu ụlọ ọrụ mmepụta ihe na-achọ ebe ndọta kwụsiri ike.

2.2 Ikuku

Ikuku bụ isi akụkụ nke transformer, a na-eji ọla kọpa na-enweghị oxygen dị elu-, yana teknụzụ na ahụmịhe anyị dị elu, ikuku ikuku nwere atụmatụ ndị a:
1. The windings na-enwe ike iguzogide ọkụ overvoltage, transient overvoltage, ogologo oge overvoltage.
2. High okpomọkụ na-eguzogide ike, ọ na-enwe ike na-aga n'ihu na-arụ ọrụ ihe karịrị 20 afọ n'okpuru okpomọkụ n'ịwa site ugbu a.
3. The windings nwere ike iguzogide mkpirisi mkpirisi mkpirisi.
4. Ike igwe dị elu.
2.3 tank
Tankị ntụgharị nke ụlọ ọrụ anyị mepụtara nwere ọtụtụ uru:
1. Ihe dị elu: Anyị na-eji ígwè dị elu na-eme ka tankị mmanụ anyị na-adịgide adịgide ma dị ike.
2. Mgbochi{1} corrosion na mgbawa - imewe ihe akaebe: A na-emeso tankị mmanụ ọkụ anyị ka ha nwee ezigbo ihe mgbochi- ma bụrụkwa nke a haziri dịka ụkpụrụ dị mkpa iji gbochie ọkụ ma ọ bụ mgbawa.
3. Nhazi nkenke: Anyị na-eji ngwá ọrụ nhazi dị elu na nkà na ụzụ iji hụ na nhazi nke ọma nke tankị mmanụ ọkụ iji hụ na akụkụ ya ziri ezi na nhazi mgbakọ.
4. Ọdịdị ọdịdị: Anyị na-aṅa ntị na ọdịdị ọdịdị nke tankị mmanụ, nke mere na ọdịdị ya mara mma ma na-emesapụ aka, mgbe ọ na-ezute ụkpụrụ ụlọ ọrụ.
5. Ikike nhazi: Anyị nwere ike ịnye ngwọta tankị ahaziri dịka ihe ndị ahịa chọrọ iji gboo mkpa nke mgbanwe dị iche iche.

2.4 Mgbakọ ikpeazụ

Mgbakọ isi na eriri igwe: Igwe isi na ikuku ikuku, nke bụ akụkụ dị mkpa nke ihe ngbanwe akpaaka, na-agbakọta ọnụ. Nke a na-agụnye idobe nke ọma na idobe eriri igwe ikuku gburugburu isi iji mepụta sekit magnetik dị mkpa maka mgbanwe voltaji.
Mkpuchi na nchebe: A na-etinye ihe mkpuchi iji chebe ikuku ikuku site na mmebi na iji hụ na nchekwa eletrik na ntụkwasị obi. Nke a nwere ike ịgụnye iji teepu mkpuchi, varnishes, ma ọ bụ mkpuchi mkpuchi ndị ọzọ.
Njikọ nke ọnụ: A na-ejikọta ọnụ ọnụ nke ikuku ikuku na njikọ ma ọ bụ njedebe kwesịrị ekwesị na ihe ntụgharị akpaaka, na-eme ka sekit eletrik zuru oke maka nnyefe ike.
03 Nnwale
1. Nnwale mkpuchi mkpuchi: Nyochaa mkpuchi mkpuchi iji hụ na arụmọrụ mkpuchi na-emezu ihe achọrọ.
2. Nnwale nkwụsị nke interturn: nwalee nkwụsị nke interturn iji hụ na mkpuchi dị mma na njikọta n'etiti windings.
3. Nnwale ule ntụgharị: Nyochaa voltaji interturn iji hụ na arụmọrụ mkpuchi n'etiti windings na-emezu ihe achọrọ.
4. Nnwale voltaji: Tinye ụfọdụ AC ma ọ bụ DC voltaji dị elu iji nwalee arụmọrụ mkpuchi nke akụrụngwa n'okpuru nrụgide dị elu.
5. Nnwale nyocha: Nyochaa arụmọrụ na arụmọrụ nke onye nrụpụta.
6. Nnwale ibu: Nyochaa arụmọrụ nke transformer n'okpuru ibu arọ.
7. Nnwale sekit dị mkpirikpi: nwalee arụmọrụ nke ihe ngbanwe n'okpuru ọnọdụ obere okirikiri.
8. Nnwale oke okpomọkụ: nwalee arụmọrụ na-arụ ọrụ na mkpuchi mkpuchi nke transformer n'okpuru ọnọdụ okpomọkụ dị elu.


04 Mbukota na mbupu
4.1 mbukota
Anyị na-ahọrọ igbe osisi dị ka ihe nkwakọba ihe n'ihi na ọ nwere ike iburu ibu na nha nke transformer. A na-echekwa transformer na nchekwa na ngwugwu na eriri ma ọ bụ braket iji gbochie mmegharị n'oge njem.

4.2 Mbupu

N'oge njikwa na njem ụgbọ njem, anyị na-elezi anya mgbe niile iji chebe ihe ntụgharị site na uzuzu, mmiri na mmebi anụ ahụ. Ejirikwa ntuziaka njikwa kwesịrị ekwesị yana akara ịdọ aka ná ntị nke ọma iji hụ na ụgbọ njem adịghị mma. N'oge njem, anyị na-enyocha ihe ntụgharị mgbe niile maka akara mmebi ma ọ bụ nchụpụ ma na-akpachapụ anya ọzọ dịka ọ dị mkpa iji hụ na nchekwa nke ibu. Mgbe ị bịarutere ebe a na-aga, a na-ewepụ ihe nkwakọ ngwaahịa ahụ nke ọma ma lelee transformer maka mmebi ọ bụla nwere ike imebi tupu echichi.
05 Saịtị na nchịkọta
Nkwadebe: Nyochaa ntọala transformer na ọnọdụ akụrụngwa, mee nyocha mkpuchi, ma dozie ngwaọrụ ebuli na mgbagha kwesịrị ekwesị.
Ịkwalite: Bulite ihe ngbanwe ahụ site na iji ebe ebuli elu akọwapụtara, hụ na ọ kwadoro ya nke ọma ma kwado ya, wee kechie ya na ntọala.
Ngwakọta Ngwa: Ugwu osisi, radiators jụrụ oyi, na ihe enyemaka ndị ọzọ, na-ahụ na a na-emechi njikọ niile ma mechie ya dịka nkọwapụta siri dị.
Ngwunye mmanụ: Mee njuputa mmanụ na-ekpo ọkụ site na iji usoro mkpocha mmanụ dị elu-. Nyochaa ọkwa mmanụ ma gosi na akara niile adịghị emebi emebi iji gbochie ntapu.
Nnwale: Mepụta mkpuchi, oke, enweghị-ibu, yana nnwale mkpirisi{1}.
Grounding: Tọọ usoro ntọ ala wee tụọ nguzogide ụwa iji hụ na arụ ọrụ dị mma na ntụkwasị obi.
Nrụ ọrụ: ugboro abụọ- lelee usoro nrụnye niile, mee nzọụkwụ{1}site {2}}Nnwale ibu nzọụkwụ, wee nye ikike nrụnye n'ihu ọha ozugbo paramita arụmọrụ niile dị n'oke oke anabatara.

Ihe nchịkọta dị ọkụ: obere ike transformer, nrụpụta, soplaya, price, efu