15 MVA Nzọụkwụ Up Power Transformer-4.16 / 69 kV|Guyana 2023

15 MVA Nzọụkwụ Up Power Transformer-4.16 / 69 kV|Guyana 2023

Obodo: Guyana 2023
Ike: 15MVA
Voltaji: 4.16/69kV
Njirimara: ya na OLTC
Zipu ozi

 

 

step up power transformer

Ike kwụsiri ike, na-enye ọdịnihu ike -họrọ ihe ngbanwe ọkụ anyị ka ọ na-amụnye ike watt ọ bụla!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

Nke a bụ 15 MVA power oil imikpu transformer bụ nke anyị rụpụtara na 2023, ikike akara nke transformer bụ 15 MVA, voltaji izizi bụ 4.16 kV na +4×1.667% na -12×1.667% tapping range(OLTC), obere voltaji bụ 69kV. Anyị na-emepụta nke a OLTC nzọụkwụ elu ike transformer na ihe Ọdịdị emewo a usoro nke isi mgbanwe, na ìhè arọ, obere size, obere ele mmadụ anya n'ihu opu, obere ọnwụ, ala mkpọtụ, elu pụrụ ịdabere, mberede mkpụmkpụ-circuit singularity nchebe, nwere ike ibelata a nnukwu ọnụ ọgụgụ nke ike okporo losses, arụ ọrụ na-eri na aku na uba uru. Ụdị njikọ YNd11 na-enye ndakọrịta grid dị mma, ebe ọ na-ebelata harmonics nke atọ ma na-emeziwanye ogo ọrụ grid nke ọma. Akụkụ voltaji dị elu (Y) bụ njikọ kpakpando na ebe na-anọpụ iche nke nwere ike ịdakwasị ozugbo ma ọ bụ site na nkwụsị ala iji nye mmepụta voltaji dị elu kwụsiri ike.

 

1.2 Nkọwa nka nka

100 MVA ike transformer nkọwa na mpempe akwụkwọ data

Enyere ya
Guyana
Afọ
2023
Nlereanya
SZ-15 MVA-69kV
Ụdị
Mgbanwe ike na-emikpu mmanụ
Ọkọlọtọ
IEEE C57.12.00
Enyere ike
15MVA
Ugboro ugboro
60HZ
Usoro
Atọ
Ụdị oyi
ONAN
Voltaji nke mbụ
69kV
Voltaji nke abụọ
4.16kV
Ngwa ikuku
Ọla kọpa
Otu Vector
YNd11
Mgbochi
9.10%
Pịa Changer
OLTC
Ọkụ aka
+4*1.667%~-12*1.667%@akụkụ HV
Enweghị mfu ibu
10.234KW (20 degrees)
Na Ibu Mfu
64.220KW (85 degrees)
Ngwa ngwa
Nhazi ọkọlọtọ
Okwu
N/A

 

1.3 Eserese

15 MVA ike mgbanwe eserese eserese na nha.

step up power transformer diagram step up power transformer nameplate

 

step up power transformer wiring diagram 15mva power transformer drawing

 

 

02 Nrụpụta

2.1 Isi

Ụlọ ọrụ anyị na-anakwere elu -conductive volt -oyi gbadoro ụkwụ- Rolled silicon steel sheet, enweghị-njide oghere, frame Ọdịdị, d{4}} Ọdịdị yoke dị elu maka eriri igwe kama ịbụ nnukwu ikpo okwu- mpaghara, nkwonkwo steepụ. Isi ya nwere obere burr na ọnụọgụ lamination dị ala. Mfu enweghị-, enweghị -load current na ọkwa mkpọtụ na-ebelata nke ọma site na nkwonkwo multi{10}} nke ogbo nke isi igwe.

core of the transformer

 

2.2 Ikuku

Continuous winding design

1. Na-aga n'ihu winding imewe: The tangle otu na-aga n'ihu ụdị na n'ime efere otu na-aga n'ihu ụdị imewe na-eji, nke na-enyere aka melite longitudinal capacitance nkesa nke eriri igwe n'okpuru mkpali voltaji. Nhazi a nwere ike ibelata ntinye nke mpaghara eletriki, nke mere na eriri igwe nwere ike ịrụ ọrụ eletrik ka mma na nrụgide dị elu.

2. eduzi mmanu mgbasa Ọdịdị: eduzi mmanụ mgbasa Ọdịdị na-eji aka belata winding okpomọkụ ịrị elu. Nhazi a na-edobe okpomọkụ n'ime eriri igwe ma na-enyere aka melite nchekwa na nkwụsi ike nke onye ntụgharị.

 

2.3 tank

1. Ịrụ ọrụ mkpuchi: A na-ekpuchi tank mmanụ na njedebe nkwụsị iji hụ na enwere ike mechie mmanụ na-ekpuchi ihe nke ọma n'ime tank mmanụ iji zere nkwụsị na oxidation nke mmanụ mkpuchi.

2. Ngwọta mgbochi corrosion -: A na-eji ihe na-emebi emebi na-eme tank mmanụ ahụ{2}, a na-eji ọgwụgwọ agba a chọrọ maka ngwa ụlọ na-eme ka nrụrụ nke tankị mmanụ dịkwuo mma ma gbasaa ndụ ọrụ.

3. Nnwale nchọpụta nyocha: weld na akara nke tank ahụ enwetala ule nchọpụta atọ nke ntanye (fluorescence, nrụgide dị mma, ule nkwụsị nke nrụgide na-adịghị mma) iji hụ na njigide na nchekwa.

oil tank

 

2.4 Mgbakọ ikpeazụ

oil conservator

Mgbakọ ikpeazụ nke transformer mmanụ na-emikpu - nke ụlọ ọrụ transformer mebere na-agụnye ọtụtụ usoro isi:

1. Mgbakọ isi: Mgbakọ bụ isi bụ nzọụkwụ mbụ na usoro mgbakọ ikpeazụ. Nke a na-agụnye ikpokọta na mkpọchi nke isi ihe ngbanwe, bụ nke nwere igwe igwe eletrik dị elu{2}} mejupụtara. A ghaghị ikpokọta isi ya ka ọ bụrụ nkọwa zuru ezu iji hụ na njirimara magnetik kacha mma yana obere mfu isi.

2. Nwụnye Windings: Usoro a gụnyere ịwụnye windings dị elu -voltaji (HV) na obere -voltaji (LV) na isi. Igwe ikuku na-abụkarị ihe mkpuchi ọla kọpa nke a na-edobe nke ọma, kechie ya ma jikọta ya dabere na nhazi nke ngbanwe.

3. Nwụnye tank na Radiator: A na-etinye tankị nke na-agbanwe agbanwe, yana radiators ọ bụla metụtara ma ọ bụ nku oyi, n'oge a. tank ahụ na-enye ụlọ maka isi na windings ma nwee ike mechie ya ka ọ nwee mmanụ mkpuchi.

4. Mkpuchi, Njikọ, na Ngwa: A na-etinye ihe mkpuchi mkpuchi, dị ka bushes, ụzọ, ndị na-agbanwe mgbata, na ngwa ndị ọzọ ma jikọọ na windings. A na-agbakwunye ihe mkpuchi na nkwado ndị ọzọ iji hụ na ọrụ nchekwa na ntụkwasị obi.

5. Mmanụ na-ejuputa na mkpuchi: A na-ejupụta na transformer na mmanụ mkpuchi site na usoro nlezianya na-achịkwa. Ozugbo e mejupụtara ya, a na-emechi ihe ntụgharị ahụ ka ọ ghara ịbanye na mmiri na iji nọgide na-enwe ezi mmanụ.

 

 

03 Nnwale

Nnwale mkpuchi mkpuchi: ejiri iji chọpụta ogo ihe mkpuchi mkpuchi iji gbochie ndakpọ mkpuchi. Ọ dị mkpa iji hụ na transformer adịghị n'ịntanetị ma jiri ngwa ule nguzogide kwesịrị ekwesị.

Nnwale voltaji dị mma: A na-etinye voltaji dị elu na transformer n'oge ule iji nwalee arụmọrụ mkpuchi ya na voltaji akara. Nke a chọrọ nrapagidesi ike na usoro arụ ọrụ dị mma yana ekwe nkwa na akụrụngwa nnwale na-erute ụkpụrụ.

Nnwale nrụgide na-adịghị mma: Ihe nnwale a na-enyocha arụmọrụ mkpuchi nke transformer na voltaji dị ala. Ọ dịkwa mkpa ịme usoro nchekwa kwesịrị ekwesị iji hụ na emere ule ahụ n'enweghị nsogbu.

Nnwale nguzogide AC: Nwalee nguzogide ala nke ikuku iji hụ na ntụkwasị obi nke sistemu ala.

Ọnwụ ike na enweghị - na-ebunye ule ugbu a: A na-eji ule ndị a tụọ arụmọrụ enweghị{1} na ibu ọrụ nke transformer.

Nnwale ibu: Site n'itinye ibu a kwadoro, a na-atụle paramita arụmọrụ nke transformer n'okpuru ọnọdụ ibu e gosiri.

 

transformer type test

 

 

04 Mbukota na mbupu

4.1 mbukota

Nkwakọ ngwaahịa na mbugharị mmanụ ọkụ na-emikpu mmanụ - nke ụlọ ọrụ transformer rụpụtara gụnyere ọtụtụ usoro dị mkpa iji hụ na ebubata ngwa ahụ n'enweghị nsogbu. N'okpuru bụ nkọwa zuru ezu nke usoro a:

1. Nkwakọ ngwaahịa: Ozugbo transformer mere mgbakọ ikpeazụ, gụnyere ule na nlele mma, a na-akwado ya maka mbukota. A na-echekwa ihe ndị na-agbanwe agbanwe, gụnyere tank, isi, windings na ngwa ndị metụtara ya, nke ọma ma chekwaa maka njem. A na-ahọrọ ihe ndị a na-akwakọba, dị ka igbe osisi, ụfụfụ ụfụfụ, na eriri, iji nye ihe nkpuchi na nchebe zuru oke.

2. Nchekwa na Nchekwa Corrosion: A na-emeso ihe ndị na-emepụta ihe na-emepụta ihe na-echekwa ihe nchebe kwesịrị ekwesị iji chebe onwe ya pụọ ​​​​na mmebi n'oge njem na nchekwa.

power transformer specification

 

4.2 Mbupu

15mva power transformer manufacturer

Nchekwa maka Ụgbọ njem: A na-echekwa ihe ndị na-agbanwe agbanwe n'ime nkwakọ ngwaahịa iji gbochie mmegharị na iji hụ na nkwụsi ike n'oge njem. A na-edobe nhazi nke ọma na nke ziri ezi iji gbochie nrụgide na-enweghị isi n'akụkụ ọ bụla nke transformer.

Nchọpụta na akwụkwọ: A na-edobe ihe ngwugwu ọ bụla, ma kwadebere akwụkwọ zuru ezu, gụnyere ndepụta nkwakọ ngwaahịa, ntụziaka mbupu, yana ikike ma ọ bụ asambodo ọ bụla achọrọ maka njem.

Nbudata na Ụgbọ njem: A na-ebunye ihe ndị ahụ ekpokọtara n'ụgbọ njem kwesịrị ekwesị, dị ka ụgbọala na-adọkpụ dị larịị ma ọ bụ arịa mbupu, na-eji cranes ma ọ bụ ngwa eji ejizi ndị ọzọ. Enwere ike ịchọrọ ụgbọ njem pụrụ iche maka nnukwu mgbanwe ma ọ bụ nke dị arọ.

Ijikwa na nbudata: N'oge njem, a na-eji nlezianya na-edozi ihe ndị na-agbanwe agbanwe ka ọ ghara imebi. Mgbe ị bịarutere ebe a na-aga, a na-akpachapụ anya mgbe a na-ebutu ya iji hụ na a na-ejikwa ya nke ọma

 

 

05 Saịtị na nchịkọta

Nkwadebe: Gbaa mbọ hụ na ntọala ahụ dị larịị ma kwụsie ike, yana ngwaọrụ niile adịla njikere.

Ụgbọ njem na ịkwanye: Bufee ihe ntụgharị gaa na saịtị ahụ, bulite ya n'ọnọdụ, ma chekwaa ya.

Ntinye mgbakwunye: Wụnye ngwa dị ka ngwaọrụ jụrụ oyi, ihe nchekwa mmanụ, na ahịhịa.

Njikọ eletrik: Mezue njikọ maka eriri elu na obere voltaji ma ọ bụ bọsbars ma hụ na ntọ ala kwesịrị ekwesị.

Ndoju mmanụ na nyocha: Wejuo ihe ntụgharị na mmanụ mkpuchi ma lelee ọkwa mmanụ na ịdị mma.

Nlele na nhazi: Mee ule eletrik dị ka mkpuchi mkpuchi, nguzogide na ule oke.

Ọrụ nnwale: Na-arụ ọrụ nnwale n'okpuru ibu ma kwadoo paramita niile tupu ịnye ọrụ ikpeazụ.