1500 KVA Igwe ọkụ eletrik-5 / 0.48 KV|USA 2025

1500 KVA Igwe ọkụ eletrik-5 / 0.48 KV|USA 2025

Obodo: USA 2025
Ike: 1500 kVA
Voltaji: 5D-0.48Y/0.277 kV
Njirimara: FR3 mmanụ
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-ebunye ọdụ ụgbọ ala eletrik 1500 kva -5/0.48 kv|US 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

electrical substations

Ihe ngbanwe nke otu nkeji - Ejikọtara ọnụ, rụọ ọrụ nke ọma na obi nke nkesa ike a pụrụ ịdabere na ya.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

Enyere 1500 kVA unit substation transformer na USA na 2025. Akara ikike nke transformer bụ 1500 kVA na KNAN jụrụ oyi. Igwe ọkụ dị elu bụ 5D kV na ± 2 * 2.5% tapping range (NLTC), obere voltaji bụ 0.48Y / 0.277 kV, ha guzobere otu vector nke Dyn1.

Ebe a na-ekesa ọkụ eletrik bụ ngwaọrụ nkesa ike kọmpat na-ejikọta mgba ọkụ bụ isi, ihe ngbanwe ọkụ ọkụ atọ{{0} na ngwa nkesa nke abụọ n'ime otu mgbakọ dị nso{1}. Emebere ya ka ọ gbatuo voltaji nkesa ngwa ọrụ gaa n'ọkwa dabara adaba maka nkesa ụlọ osisi ma ọ bụ nke azụmahịa, ma dabara adaba maka nrụnye ime ụlọ na n'èzí. Site na imewe ya- ejikọtara ọnụ, enwere ike idowe transformer n'akụkụ ebe a na-ebu ibu, na-ebelata oke eriri USB na ogologo ụzọ ụgbọ ala, nke na-ebelata mfu ahịrị na mmejọ ma na-emelite ụkpụrụ voltaji na ịga n'ihu nke ọrụ. Tụnyere usoro ọdụ ụgbọ ala a na-ahụkarị, akara ukwu ya kọmpat na-echekwa ohere nrụnye, na-ebelata ọnụ ahịa ihe owuwu na saịtị na njem, ma na-ebelata mmefu mmezi ogologo oge{{8} site na ngwa ngwa ngwa. Igwe ngbanwe nke otu unit na-agbaso ụkpụrụ ANSI, IEEE, na NEMA nke ọma, na-ahụ na nhazi ọkụ eletrik na igwe zuru ezu. Dị ka nhọrọ, transformer nwere ike jupụta FR3™ natural ester fluid{12}}a mmeghari ohuru, akwukwo nri{13}}mmanu{14}}dielectric dabere na elu oku oku na gburugburu ebe obibi mara mma{15} mgbe mmanụ ịnweta nkịtị ka dị maka ngwa nwere ọkọlọtọ chọrọ. Site na ntụkwasị obi ya dị elu, arụmọrụ, na nhazi mgbanwe, nkeunit substation transformera na-ejikarị eme ihe na ụlọ ọrụ mmepụta ihe, ụlọ azụmahịa, ụlọ ọrụ mmepụta ihe, na netwọk akụrụngwa dị egwu ebe ohere, nchekwa, na arụmọrụ dị mkpa.

 

 

 

1.2 Nkọwa nka nka

1500kV eletriki substations ụdị nkọwa na mpempe akwụkwọ data

Enyere ya
USA
Afọ
2025
Ụdị
unit substation transformer
Ọkọlọtọ
IEEE
Enyere ike
1500 kVA
Ugboro ugboro
60HZ
Usoro
3
Ụdị oyi
KNAN
Voltaji nke mbụ
5D kV
Voltaji nke abụọ
0.48Y/0.277 kV
Ngwa ikuku
Ọla kọpa
Otu Vector
YNyn0
Mgbochi
5.75%±7.5%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
1.545 kW
Na Ibu Mfu
10.54 kW

 

1.3 Eserese

1500 kVA eletriki substations eserese na nha.

electrical substations diagram electrical substations nameplate

 

 

02 Nrụpụta

2.1 Isi

electrical substations core

Core uses CRGO silicon steel, perfectly matched to 1500kVA, 5.0/0.48kV, Dyn1, 60Hz (no‑load loss 1.545kW, load loss 10.540kW). Design & manufacturing comply with IEEE C57.12.34-2022, C57.12.00-2021 & C57.12.90-2021. Tests confirm: max turns ratio deviation +0.16% (well below 0.5%), losses and impedance meet guaranteed values. Quality: five‑step step‑lap process reduces eddy losses and noise; core clamped and coated against moisture/rust. Highlights: step‑lap cuts no‑load current ~12% and transverse leakage >50%; 45 ogo nkwonkwo mitered ezigbo flux steering.

 

2.2 Ikuku

HV winding na 2×2.5% on-load taps (5 taps), LV Y-jikọrọ 480V/277V + na-anọpụ iche. Nsonaazụ ule (lee tebụl dị n'okpuru) na-egosi enweghị nguzozi nke LV 1.11%, HV max enweghị oke 0.80%; mkpuchi mkpuchi & nguzo ndọta niile gafere. Ogo: ọla kọpa dị elu, Klas F (ogo 155) mkpuchi, ihicha vapour-phase. Isi ihe: imewe HV na-aga n'ihu/nkwụsịtụ aka, foil/helical LV windings, mkpịsị njedebe agbakwunyere maka ihe mgbochi okirikiri dị mkpụmkpụ.

Nwale ihe

Uru/ Nsonaazụ tụrụ atụ

Ọkọlọtọ chọrọ

Nguzogide ikuku HV (mpịakọta 5)

0.0699Ω (3-phase nkezi.)

Oke enweghị oke na-erughị ma ọ bụ haha ​​1%

Nguzogide ifufe nke LV

0.714/0.706/0.713 mΩ

Enweghị nha nha 1.11%

LV na-anọpụ iche ebe nkwụsị

0.388/0.380/0.376 mΩ

Enweghị nha nha 3.07%

Mgbochi mkpuchi (HV-GND, wdg)

Gafe

Lee akụkọ

Nnwale nguzozi magnetik

Voltaji dabara adaba kwa nzọụkwụ

Enweghị ajọ mbunobi

electrical substations copper winding

 

2.3 tank

Tank emebere na stiffeners; nwalere na +50kPa na -67kPa. Nsonaazụ (lee tebụl): mgbe ahapụchara, mgbagha na-adịgide adịgide Ihe na-erughị ma ọ bụ hà nhata 0.03mm na isi 10 niile, enweghị mmebi - ule abụọ ahụ gafere. Ogo: ígwè dị elu, nyocha 100% weld, ule nrụgide dị iche iche tupu mgbakọ. Isi ihe: nhazi ọgịrịga kachasị mma, ntinye ọkụ ịgbado ọkụ na-achịkwa, imepụta gasket megide ntapu mmanụ & ntinye mmiri.

Nnwale nrụgide dị mma (50kPa):

Ntụtu aka

1

2

3

4

5

6

7

8

9

10

Nke mbụ (mm)

1.50

1.50

1.50

1.50

1.30

1.50

1.50

1.50

1.20

1.50

Mgbe etinyere nrụgide (mm)

2.19

+3.00

+3.00

2.72

2.10

1.72

2.07

1.94

2.15

1.98

Mgbe ahapụchara nrụgide (mm)

1.51

1.52

1.52

1.51

1.51

1.51

1.51

1.52

1.52

1.50

Ntụgharị na-adịgide adịgide (mm)

0.01

0.02

0.02

0.01

0.01

0.01

0.01

0.02

0.02

0.02

 

Nnwale oghere (-67kPa):

Ntụtu aka

1

2

3

4

5

6

7

8

9

10

Nke mbụ (mm)

1.51

1.52

1.52

1.51

1.51

1.51

1.51

1.52

1.52

1.52

Mgbe etinyere oghere (mm)

0.71

-0.00

-0.00

-0.00

0.78

1.12

0.89

1.01

0.85

0.92

Mgbe ahapụchara oghere (mm)

1.49

1.49

1.50

1.48

1.49

1.49

1.49

1.49

1.49

1.50

Ntụgharị na-adịgide adịgide (mm)

0.02

0.03

0.02

0.03

0.02

0.02

0.02

0.03

0.03

0.01

 

electrical substations tank past pressure test

 

2.4 Mgbakọ ikpeazụ

electrical substations active part

Mgbakọ: mgbada isi-coil, ọgwụgwọ mmanụ agụụ, nrụnye ohia/ihe mgbakwunye, nhazi ndu Dyn1. Nnwale emechara ọkara (mgbe ihichachara, tupu tankị) niile gafere: nguzogide mkpuchi, ntụgharị ntụgharị (max dev. 0.16%), mmekọrita oge (Dyn1), nguzogide ikuku, impedance (5.75%), itule ndọta. Ogo: ndekọ ọkwa ọ bụla, vacuum-mmanụ ekpochapụrụ, arụ ọrụ mgbanwe mgbata enwetara. Isi ihe: ihicha agụụ & impregnation, jigs ziri ezi maka mkpochapụ isi-tank, mkpọchi ike nke njikọ niile.

 

 

03 Nnwale

Nnwale na-ekpuchi ọkụ eletrik, igwe & ọrụ mkpuchi kwa IEEE C57.12.00-2021 & C57.12.90-2021.

Nwale ihe

Nsonaazụ ule

Mmechi

Mgbochi mkpuchi (HV-GND, LV-GND, HV-LV, isi-frame)

Gafe

Gafe

Ntụgharị nha nha

<0.2% per tap

Gafe

Mmekọrịta nke usoro

Dyn1

ziri ezi

Enweghị oke nguzogide ikuku

LV 1.11%, HV 0.80%

Magburu onwe

Mkpịsị aka ike nke okirikiri

5.75%

Na-enweta uru ekwenyere

Nnwale nguzozi magnetik

3-phase voltaji itule

Gafe

Nnwale nrụgide dị mma (50kPa)

Ntugharị na-adịgide adịgide Ihe na-erughị ma ọ bụ haha ​​0.02mm

Gafe

Nnwale oghere (-67kPa)

Ntugharị na-adịgide adịgide Ihe na-erughị ma ọ bụ haha ​​0.03mm

Gafe

Nyocha anya nke tank

Enweghị mmebi

Gafe

electrical substations short-circuit impedance
electrical substations routine test

 

 

04 Mbukota na mbupu

4.1 mbukota

Crates osisi omenala, osisi ISPM15 a na-agwọ ọkụ maka mkpochapụ kọstọm na-enweghị fumigation. Ekwenyere ntụkwasị obi site na nlebanya mbupu & ịme anwansị ịma jijiji. Ọdịmma: eriri ụzọ isii + mgbochi-slip pads (mmegharị<2mm), cushioning material, moisture/rust protection. Highlights: centre of gravity & lifting points marked, 100% pre‑pack inspection, spare parts in same crate.

electrical substations packed with custom wooden crates

 

4.2 Mbupu

electrical substations shipping under CIF term

Ụgbọ njem n'oké osimiri/ala dabara na ebe a na-aga; traceable site na nkwekọrịta & nọmba serial. Na-agbaso ụkpụrụ incoterms & mbupụ; nlele tupu mbupu na-eju omenala. Ekwenyere ntụkwasị obi site na ịme anwansị ịma jijiji. Ọdịmma: akara ihu igwe anaghị egosi "atụba/dobe" akara, nlele nbudata, akwụkwọ mbupu zuru oke & COO. Isi ihe: ihe eco-friendly ihe, ihe ngosi ujo na nnukwu nkeji, ndepụta mbukota/ndepụta arọ/esere akụkụ.

 

05 Nchịkọta

Na nchịkọta, ọdụ ụgbọ ala eletrik 1500kVA na-enye arụmọrụ eletrik pụrụ iche, nrụsi ike n'arụ ọrụ, yana nnabata zuru oke na IEEE C57.12.34-2022. Site na isi na mfu ikuku na-ezute ụkpụrụ ekwenyere, mgbanaka voltaji dị n'okpuru 0.2%, enweghị nguzozi na-eguzogide ikuku dị ka 1.11%, yana nrụrụ tankị na-adịgide adịgide n'okpuru ule nrụgide / agụụ na-ejedebe na ihe na-erughị ma ọ bụ nhata 0.03mm, ọ na-enye ihe ngwọta pụrụ ịdabere na ya, obere ndụ okirikiri. Nnwale siri ike nke ọkara emechara na ikpeazụ - site na nguzogide mkpuchi maka itule magnetik na nrụrụ tank - na-eme ka ngalaba ọ bụla hapụ ụlọ nrụpụta ahụ dị njikere maka ngwa ngwa chọrọ.Họrọ SCOTECHdị ka onye gị na ya tụkwasịrị obi iji wuo akụrụngwa eletriki nke nwere ọgụgụ isi na nke na-agbanwe agbanwe.

electrical substations supplier

 

 

Ihe nchịkọta dị ọkụ: ụlọ ọrụ eletriki, onye nrụpụta, onye na-ebu, ọnụahịa, ọnụ ahịa

Next2:Enweghị Ozi

Zipu ozi