1000/1150 kVA nkesa nkesa ihe ntụgharị-13.8 / 0.48 kV|USA 2025
Ike: 1000/1150 kVA
Voltaji: 13.8-0.48GrdY/0.277kV
Njirimara: ya na mmanụ FR3 na CT

Kwụpụ ntụkwasị obi, gbadata nkwụsị - ndị na-eme mgbanwe na-eme ka grid dị ndụ!
01 Izugbe
1.1 Nkọwa oru ngo
1000/1150 kVA substation transformer e zigara America na 2025. The gosiri ike nke transformer bụ 1000/1150 kVA na KNAN/KNAF jụrụ. The isi voltaji bụ 13.8 kV na ± 2 * 2.5% tapping nso (NLTC), nke abụọ voltaji bụ 0.48GrdY / 0.277 kV, ha guzobere vector otu Dyn1.
Emebere ihe ngbanwe nke 2000/2300 kVA iji wepụta nkesa ike a pụrụ ịdabere na ya maka ụlọ Junction - 1. Transformer jupụtara na mmiri mmiri FR3® dielectric, mmanụ na-adịgide adịgide ma dị elu{{4}mmanụ na-eme ka ọ dị elu nke na-eme ka nkwụsi ike nke okpomọkụ dịkwuo elu, na-agbatị ndụ akụrụngwa, ma na-enye nchekwa gburugburu ebe obibi dị elu ma e jiri ya tụnyere mmanụ ịnweta mmanụ.
Otu akụkụ nchekwa dị mkpa nke sistemu a bụ 5-amp neutral grounding resistor (NGR), nke na-amachi mmejọ nke ugbu a ma na-echebe onye ngbanwe site na mmebi n'oge mmejọ ala. A na-enyocha NGR site na ngbanwe dị ugbu a nke 5: 5 (CT) nwere ogo C10 ziri ezi, na-ahụta nchọta mmejọ na nchedo sistemu.
Emebere ya maka ịdịte aka yana nnabata n'ụkpụrụ ụlọ ọrụ, transformer a na-ahụ maka nnyefe ike kwụsiri ike ma na-ebute nchekwa, nkwado na arụmọrụ arụmọrụ maka Ụlọ Junction - 1.
1.2 Nkọwa nka nka
1000/1150 kVA substation transformer ụdị na mpempe akwụkwọ data
|
Enyere ya
America
|
|
Afọ
2025
|
|
Ụdị
Ihe ntụgharị ọdụ ụgbọ mmiri
|
|
Ọkọlọtọ
ANSI/IEEE C57.12.00
|
|
Enyere ike
1000/1150 kVA
|
|
Ugboro ugboro
60HZ± 6%
|
|
Usoro
3
|
|
Ụdị oyi
KNAN/KNAF
|
|
Voltaji nke mbụ
13.8 kV
|
|
Voltaji nke abụọ
0.48GrdY/0.277 kV
|
|
Ngwa ikuku
Ọla kọpa
|
|
Ntugharị akụkụ
Dyn1
|
|
Mgbochi
6%
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
±2*2.5%
|
|
Enweghị mfu ibu
Ihe na-erughị ma ọ bụ hà nhata 1.335kW
|
|
Na Ibu Mfu
Ihe na-erughị ma ọ bụ hà 8.2kW
|
1.3 Eserese
1000/1150 kVA substation transformer eserese na nha.
![]() |
![]() |
02 Nrụpụta
2.1 Isi
A na-ewukarị isi ihe ngbanwe mgbanwe-fase atọ, atọ{1}} site na iji mpempe akwụkwọ nchara silicon ekpokọbara ekpokọbara iji wedata mfu efu ugbu a wee hụ na arụmọrụ magnetik dị elu. Nhazi a nwere akụkụ ụkwụ kwụ ọtọ atọ jikọtara ya na yokes nke elu na nke dị ala, na-enye ụzọ magnetik ziri ezi maka mgbagharị agba atọ-. Usoro lamination a kpọkọtara - na-akwalite nkwụsi ike n'ọrụ, na-ebelata mfu -, ma na-emeziwanye arụmọrụ mgbanwe n'ozuzu ya. Nhazi ya siri ike yana kọmpat na-eme ka ọ dị mma maka ngwa mgbasa ozi na nkesa ike dị elu-.
2.2 Ikuku

Ikuku LV:Ejiri foil ọla kọpa mee, nke ejiri mkpuchi interlayer mee ya nke ọma, na-enye ezigbo mkpụmkpụ ike mkpirisi na arụmọrụ ọkụ.
Ikuku HV:Ejiri waya ọla kọpa mebere ya na oyi akwa{0}}ụdị imewe, na-ahụ na ntụgharị a pụrụ ịdabere na ya{1} ka-atụgharị mkpuchi maka nnukwu ntachi obi voltaji na nkwụsi ike nke igwe.
2.3 tank
Tankị ahụ na-eje ozi dị ka ihe mkpuchi nchebe, nke ejiri nchara welded zuru oke ma ọ bụ ogwe ndị a kwadoro iji hụ na iguzosi ike n'ezi ihe na-eme ka ọ dịkwuo ọkụ. N'elu ya na-anagide ájá ájá na mkpuchi ọtụtụ{1}Layer anti- corrosion mkpuchi maka ogologo oge{3}} ogologo oge n'èzí. Juputara na mmanụ mkpuchi ọkwa dị elu{5}, tank ahụ na-enye ma mkpuchi eletriki yana oyi dị mma site na mgbasa mmanụ. Mgbakọ tank na-agụnye bushes, mmanụ okpomọkụ / ọkwa ọkwa, ngwaọrụ enyemaka nrụgide, na Buchholz relay. Mgbidi dị n'akụkụ jikọtara radiators mbughari, nwere valvụ mmiri na-agbapụta na ọdụ ụgbọ mmiri na ala, na-eme usoro zuru oke maka nchekwa, jụrụ oyi na nlekota.

2.4 Mgbakọ ikpeazụ

Mgbakọ ikpeazụ na-ejikọta isi, HV / LV windings, na usoro mkpuchi n'ime tankị corrugated mgbe ihicha oghere na njuputa mmanụ. A na-etinye ihe ndị dị mkpa dị ka bushes, ngwaọrụ jụrụ oyi, relays nchebe, na sistemụ nleba anya, na-esote ule hermetic na ule oge niile iji chọpụta iguzosi ike n'ezi ihe nke igwe, ịrụ ọrụ eletrik, yana ntụkwasị obi arụ ọrụ n'otu ụkpụrụ.
03 Nnwale
|
Mba. |
Nwale ihe |
Nkeji |
Ụkpụrụ nnabata |
Ụkpụrụ ndị atụtara |
Mmechi |
|
1 |
Ntụle Nguzogide |
% |
Ọnụego enweghị nguzozi kachasị elu |
3.64 |
Gafe |
|
2 |
Nlele oke |
% |
Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha 0.5% |
-0.03~0.07 |
Gafe |
|
3 |
Usoro{0}}Nnwale mmekọrịta |
/ |
Dyn1 |
Dyn1 |
Gafe |
|
4 |
Ọ dịghị - ibu mfu na mkpali ugbu a |
% |
I0 :: nye uru a tụrụ atụ |
0.22 |
Gafe |
|
kW |
P0: nye uru a tụrụ atụ |
1.072 |
|||
|
/ |
nnabata maka enweghị ibu ibu bụ +0% |
/ |
|||
|
5 |
Mfu ibu , impedance voltaji, ngụkọta mfu na arụmọrụ |
/ |
t:85 ogo nnabata maka mgbochi bụ +7.5% Nkwenye maka mkpokọta mfu ibu bụ +0% |
/ |
Gafe |
|
% |
Z%: uru tụrụ |
5.97 |
|||
|
kW |
Pk: uru tụrụ |
7.924 |
|||
|
kW |
Pt: uru tụrụ |
8.996 |
|||
|
% |
Ịrụ ọrụ adịghị erughị 99.27% |
99.32 |
|||
|
6 |
Nnwale voltaji etinyere |
/ |
HV: 34kV 60s LV: 10kV 60s |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
7 |
Nnwale Nkwụghachi Voltaji butere |
/ |
Voltaji etinyere (kV): 0.96 |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
Ogologo oge (s):40 |
|||||
|
Ugboro (HZ): 180 |
|||||
|
8 |
Ntụle Nguzogide mkpuchi |
GΩ |
HV -LV n'ala: |
6.52 |
/ |
|
LV-HV gaa n'ala: |
8.20 |
||||
|
HV&LV n'ala: |
6.80 |
||||
|
9 |
Ule ntapu |
/ |
Ntinye nrụgide: 50kPA |
Enweghị ntapu na mba Mmebi |
Gafe |
|
Ogologo oge: 12h |
|||||
|
10 |
Nnwale mmanụ |
kV |
Ike Dielectric |
49.7 |
Gafe |
|
mg/kg |
Ọdịnaya Ọdịnaya |
186.3 |
|||
|
% |
Ihe nchụsa |
2.118 |
|||
|
mg/kg |
Nyocha nke Furan |
/ |
|||
|
/ |
Nyocha chromatography gas |
/ |


04 Mbukota na mbupu
4.1 mbukota
Ihe ngbanwe eletrik juru n'ime igwe igwe{0}}ụkpụrụ ngwakọ osisi, ejiri ihe nkiri mgbochi- nchara kechie yana ihe na-awụ akpata oyi n'ahụ-. Eriri igwe na-eme ka mpụta, na-eji akara ebuli elu na iru mmiri{4}} iji gbochie mmebi igwe na mmebi gburugburu ebe obibi n'oge njem.
4.2 Mbupu
Ụgbọala dị arọ- na-ebu ụzọ buo ọdụ ụgbọ mmiri a na-ebuga n'ọdụ ụgbọ mmiri, yana ngwaọrụ nchekwa pụrụ iche na-eme ka nkwụsi ike. Mgbe ebubata akpa n'ọdụ ụgbọ mmiri bịarutere, a na-ebunye ya n'ime akpa ma ọ bụ akwa dị larịị, gbasie ike, ma gwọọ ya maka nchekwa mmiri tupu ebuga ya n'ụgbọ mmiri. Mgbe ị na-ebufe, a na-echekwa akpa ahụ n'elu oche ma ọ bụ na njide, na-eji ezigbo oge na-enyocha ọnọdụ okpomọkụ, iru mmiri na ịma jijiji iji kwe nkwa ịnyefe nchekwa n'ọdụ ụgbọ mmiri ebe a na-aga.
05 Saịtị na nchịkọta
Dị ka isi nkuku nke ike sistemu, anyị substation transformers pụtara maka elu ntụkwasị obi, elu arụmọrụ, na ogologo ndụ, n'ịhụ ike ike nnyefe n'ụwa nile. Site n'iji teknụzụ na-egbutu{1} na njikwa mma siri ike, anyị na-ebuga ngwọta ahaziri iche iji gboo ihe dị iche iche chọrọ. Ịhọrọ ngwaahịa anyị pụtara ịnakwere nchekwa, arụmọrụ, na ọdịnihu ike na-adịgide adịgide.

Ihe nchịkọta dị ọkụ: nkesa ihe ngbanwe, onye nrụpụta, onye na-eweta, ọnụahịa, ọnụ ahịa
You Might Also Like
3000 kVA ntụgharị-25 / 0.6 kV|Canada 2025
630 kVA Nkedo eriri igwe ntụgharị-6.6 / 0.55 kV|Sout...
3000 kVA Igwe ọkụ eletrik-44 / 0.6 kV|Canada 2025
3750/4250 kVA Substation Transformer-13.8 / 0.48 kV|...
2000/2300kVA Ntugharị ihe ntanetị eletriki-13.8 / 0....
2000 kVA nkesa nkesa ihe ntụgharị-44 / 0.48 kV|Canad...
Zipu ozi