750 KVA Pad na-ebunye ihe ntụgharị ọnụahịa-4.16 / 0.6 KV|Canada 2025

750 KVA Pad na-ebunye ihe ntụgharị ọnụahịa-4.16 / 0.6 KV|Canada 2025

Obodo: USA 2025
Ike: 750 kVA
Voltaji: 4.16/0.6 kV
Njirimara: ya na mmanụ Luminol
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-ebunye ọnụ ahịa 750 kva pad mounted transformer-4.16/0.6 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

750 kVA pad mounted transformer price

Ihe ngbanwe nke mpe mpe akwa: Ike echedoro, Nhazi agbatị, arụmọrụ kachasị elu.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

2000 kVA three phase pad mounted transformer e zigara Canada na 2025. Ike nke transformer bụ 300 kVA na KNAN jụrụ oyi. Igwe ọkụ dị elu bụ 4.16D kV na ± 2 * 2.5% tapping range (NLTC), obere voltaji bụ 0.6Y / 0.347 kV, ha guzobere otu vector nke Dyn1.

SCOTECH's pad mounted transformer bụ ihe aga - iji kwalite ngwọta maka obere azụmaahịa, obodo obibi na ebe azụmahịa mpaghara. N'ịbụ nke e bu n'uche na-arụ ọrụ nke ọma ohere, akara ukwu ya dabara adaba n'ime nnukwu obodo mepere emepe, ebe a na-adọba ụgbọala, na okporo ụzọ- na-ewepụ mkpa maka nrụnye dị n'elu nke na-akpaghasị okporo ámá. Ihe mgbochi-Mgbachi nchara na-egosi na oghere oghere nwere ike ime ka nchekwa dị oke, na-egbochi ntinye na-akwadoghị yana ibelata ihe egwu dịịrị ndị njikwa ihe. Site na nrụnye nkwụnye {{6} na -egwu, ọ na-ebelata oge ọrụ saịtị site na 30% ma e jiri ya tụnyere ihe ngbanwe ọdịnala, na-enye ohere ịgbalite ngwa ngwa maka ụlọ ahịa ọhụrụ, ụlọ ụlọ, na ogige obodo. Ọrụ ya dị jụụ (ihe na-erughị ma ọ bụ hà nhata 50dB) na-ahụ na ọ gaghị akpaghasị ihe omume kwa ụbọchị, na-eme ka ọ bụrụ onye agbata obi{12}}nhọrọ enyi na enyi maka ebe obibi.

 

 

 

1.2 Nkọwa nka nka

750 kVA mpe mpe akwa akwadoro ụdị nkọwapụta na mpempe data

Enyere ya
Canada
Afọ
2025
Ụdị
Ihe mgbakwasa na mpe mpe akwa
Ọkọlọtọ
CSA C227.4:21
Enyere ike
300 kVA
Ugboro ugboro
60HZ
Usoro
3
Nri
Loop
N'ihu
Nwụrụ anwụ
Ụdị oyi
Mmanụ Luminol (ONAN)
Voltaji nke mbụ
4.16D kV
Voltaji nke abụọ
0.6Y/0.347 kV
Ngwa ikuku
Ọla kọpa
Otu Vector
Dyn1
Mgbochi
4%
Ịrụ ọrụ
99.15%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
0,65 kW
Na Ibu Mfu
4.25 kW

 

1.3 Eserese

750 kVA mpe mpe akwa akwadoro eserese eserese na nha.

750 kVA pad mounted transformer diagram 750 kVA pad mounted transformer nameplate

 

 

02 Nrụpụta

2.1 LV

LV bushing for pad-mounted transformer

The LV bushing for pad - n'agbanyeghi ihe ngbanwe nke na-egosi elu igwe na-arụ ọrụ nke nwere tin{1} na ntinye kwụ ọtọ. Isi nkọwa gụnyere 10kV ike ugboro akọrọ na-eguzogide voltaji, 30kV ọkụ ọkụ ọkụ ọkụ, Ihe na-erughị ma ọ bụ hà nhata 10pC partial mwepu (1.2kV), 31.25kA/2s mkpụmkpụ -oge thermal ugbu a, 1250N cantilever ibu ikike, na ukwuu karịa ma ọ bụ hà creepage 35mm Kwesịrị ekwesị maka gburugburu - ogo 35 ruo +40 ogo, ọ na-abịa na mgbanaka akara akụkụ anọ ∅72×∅54×6, dabara oghere kabinet akọwapụtara, ma edozi ya site na studs welded, na-eme ka njikọ mkpuchi ọkụ dị ala nwere ntụkwasị obi.

 

2.2 Nlele ọkwa mmanụ

Ihe nlele ọkwa mmanụ na-enye ihe ngosi ọkwa mmanụ dị mma, nke nwere ọgụgụ isi na nke a pụrụ ịdabere na ya na ndụ ọrụ dị ogologo ma e jiri ya tụnyere nlele iko. Na-arụ ọrụ n'okpuru ọnọdụ nke - 40 ~ 80 degrees ambient okpomọkụ, ihe na-erughị ma ọ bụ hà 90% iru mmiri, na elu Na-erughị ma ọ bụ hà nhata 2000m (chọrọ perpendicular arịọnụ, ọ dịghị nkọ ma ọ bụ ike magnetik dị nso), ọ mejupụtara a sere n'elu, njikọ lever, njide, magnetik nchara, na egosi si n'ụzọ zuru ezu {7} ígwè egosi. hụ na akara. Ka ọkwa mmanụ nke transformer na-ebili ma ọ bụ daa n'ihi mgbanwe okpomọkụ ma ọ bụ ihe ndị ọzọ, ihe na-ese n'elu mmiri na-aga n'otu aka ahụ iji kwọọ pointer maka ọkwa ọkwa doro anya; ọ na-egosipụta O-mgbanaka maka mkpuchi mmanụ, ọ dịghịkwa achọ nkukota ma ọ bụ ịgbatị / ịgbagọ nke eriri njikọ iji nọgide na-arụ ọrụ.

Oil Level Gauge

 

2.3 Ntinye Bushing

Bushing Insert

Ihe ntinye ohia nke 2701A4 maka igwe nrụnye n'elu pad, kwekọrọ n'ụkpụrụ CSA, bụ 25kV, 200A loadbreak akụrụngwa na-egosipụta peroxide{4}ọkpụkpọ a gwọọ, ọta ihu igwe PBT na-acha anụnụ anụnụ, hex{5}}broach maka nrụnye torque, yana ntinye njikọ ala. Enyere okpu nchebe, mmanụ mmanu na ntuziaka nrụnye, ọ na-eme ka njikọ eriri mkpuchi kpuchie site na olulu mmiri ọkọlọtọ.

 

2.4 Ogwe ọla kọpa

Ogwe ọla kọpa na-agbada maka mpe mpe akwa{1}}conductivity, corrosion - akụrụngwa na-eguzogide (nke a na-agbanyekarị tin -plated maka ogologo ogologo oge) nke e mere iji chegharịa ikuku na-adịghị mma na ala, na-echekwa akụrụngwa na ndị ọrụ. Emepụtara ya ka ọ dabara na ihe mgbakwasị ala nke transformer chọrọ, ọ na-egosipụta usoro siri ike maka nrụnye echekwabara, na-agbaso ụkpụrụ nchekwa ụlọ ọrụ, ma na-ahụ maka ịrụ ọrụ mgbakwasa a pụrụ ịdabere na ya na pad dị n'èzí siri ike-.

Grounding Copper Bar

 

2.5 Mpempe ebe a na-adọba ụgbọala

Parking Stand Bracket

Ihe nkwụdo ebe a na-adọba ụgbọala maka mpe mpe akwa{0} agbakwunyere ngbanwe bụ ihe siri ike, nke a na-ejikarị U{1} n'ụdị nkwado ọla edobere n'akụkụ mgbidi ime nke kabinet transformer. Ọrụ ya bụ isi bụ ịnye nchekwa nchekwa, nchekwa nwa oge na ebe nkwado maka njikọ dị elu akwụsịla -voltage loadbreak elbow connector (ka na-ejikọta ya na eriri ya). Ihe nkwado ahụ nwere obere nwa ma ọ bụ nko raara onwe ya nye iji jide ahụ mkpuchi nke ikpere n'ala nke ọma, na-egbochi nsogbu na eriri ahụ yana hụ na kọntaktị stud na-enye ume ma ọ bụ ihe ndị na-eduzi ikpere ụkwụ na-adakwasịrị nke ọma na kewapụrụ ya. Nke a na-edobe nzuko ikpere ụkwụ, na-echebe site na mmebi anụ ahụ, mmiri mmiri, na mmetọ mgbe a na-arụ ọrụ na akụkụ ndị ọzọ nke akụrụngwa.

 

 

03 Nnwale

Nnwale Ratio maka pad{0} mounted transformers bụ usoro nkwenye siri ike emebere iji gosi na oke voltaji dị n'etiti ikuku dị elu -voltaji na obere{2}} voltaji windings dabara na nkọwapụta. N'oge ule ahụ, a na-etinye voltaji - ugboro ugboro n'otu ikuku (nke kachasị elu{5} akụkụ voltaji), ma a na-atụkwa voltaji a kpalitere na ikuku nke ọzọ; A na-agbakọ oke voltaji n'ezie wee jiri ya tụnyere ọnụ ọgụgụ nke aha ya, yana ngbanwe achọrọ dabara n'ime oke ụlọ ọrụ ma ọ bụ oke nrụpụta. Nnwale a na-eme ka mgbanwe ike ziri ezi, na-egbochi nnyefe ike na-adịghị mma, ma na-akwado iguzosi ike n'ezi ihe nke winding ntụgharị nhazi, nke dị mkpa maka ịrụ ọrụ ntụkwasị obi nke transformer na netwọk nkesa.

 

 

04 Saịtị na nchịkọta

SCOTECH's pad mounters transformers na-ebunye ndị a pụrụ ịdabere na ya, ohere{0} na-echekwa ike nkesa maka mkpa obodo, azụmahịa na ụlọ ọrụ mmepụta ihe. Nrụgide siri ike, dị ala{2} ma ahaziri ya na nkọwapụta gị, ha na-eme ka ọrụ gị na-aga nke ọma.
Họrọ SCOTECH - onye mmekọ gị tụkwasịrị obi maka akụrụngwa ike kwụsiri ike.

750 kVA pad mounted transformer supplier

Ihe nchịkọta dị ọkụ: 750 kVA mpe mpe akwa akwanye ọnụahịa mgbanwe, onye nrụpụta, onye na-ebu, ọnụahịa, ọnụ ahịa

Zipu ozi