500 KVA Pad Nkwanye Ntugharị Ndị Na-emepụta Ihe-4.16 / 0.6 KV|Canada 2025

500 KVA Pad Nkwanye Ntugharị Ndị Na-emepụta Ihe-4.16 / 0.6 KV|Canada 2025

Obodo: Canada 2025
Ike: 500 kVA
Voltaji: 4.16/0.6 kV
Njirimara: ya na mmanụ Luminol
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị a pụrụ ịdabere na ya na ndị na-emepụta ihe na ndị na-ebunye 500 kva pad mounted transformer -4.16/0.6 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

pad mounted transformer manufacturers

Ihe ngbanwe na mpe mpe akwa: na-ebuli oge elu, na-ebelata akara ukwu.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

2000 kVA three phase pad mounted transformer e zigara Canada na 2025. Ike nke transformer bụ 500 kVA na KNAN jụrụ oyi. The elu voltaji bụ 4.16Y / 2.4 kV na ± 2 * 2.5% tapping nso (NLTC), ala voltaji bụ 0.6D kV, ha guzobere a vector otu YNd1.

Maka azụmahịa na ndị na-eweta ọrụ na-achọ nchekwa, ọnụ ahịa{0}dị irè, yana oghere{1} na-echekwa ngwọta nkesa ọkụ, SCOTECH's pad mounted transformer na-eguzo dị ka nhọrọ kacha mma. Ahaziri iji lebara isi ihe mgbu nke njikwa ike obodo mepere emepe-gụnyere ohere nrụnye nwere oke, ọnụ ahịa nrụzi dị elu na ihe egwu nchekwa{4}} transformer a na-agwakọta ọmarịcha profaịlụ{{5} dị ala yana arụrụ ọrụ siri ike. Nhazi ya mechiri emechi na-egbochi kọntaktị mberede, na-eme ka ọ zuo oke maka mpaghara okporo ụzọ- dị elu dị ka nnukwu ụlọ ahịa, ogige ụlọ akwụkwọ, na obodo obibi. N'iji obere ihe ndozi chọrọ yana ogologo ndụ ọrụ, ọ na-ebelata mkpokọta ọnụ ahịa nke nwe (TCO) maka ndị ọrụ ka ọ na-ahụ na ọkụ anaghị akwụsị akwụsị. Ma maka ọrụ owuwu ọhụrụ ma ọ bụ grid retrofits, SCOTECH's pad mounted transformer na-enye uru a na-ahụ anya site n'ịkwalite arụmọrụ ike, belata mmefu arụmọrụ, na ibute nchekwa ọha.

 

 

 

1.2 Nkọwa nka nka

500 kVA mpe mpe akwa akwadoro ụdị nkọwapụta na mpempe data

Enyere ya
Canada
Afọ
2025
Ụdị
Ihe mgbakwasa na mpe mpe akwa
Ọkọlọtọ
CSA C227.4:21
Enyere ike
500 kVA
Ugboro ugboro
60HZ
Usoro
3
Nri
Loop
N'ihu
Nwụrụ anwụ
Ụdị oyi
Mmanụ Luminol (ONAN)
Voltaji nke mbụ
4.16Y/2.4kV
Voltaji nke abụọ
0.6D kV
Ngwa ikuku
Ọla kọpa
Otu Vector
YNd1
Mgbochi
4%
Ịrụ ọrụ
99.05%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
0,65 kW
Na Ibu Mfu
4.25 kW

 

1.3 Eserese

500 kVA mpe mpe akwa akwadoro eserese eserese na nha.

pad mounted transformer manufacturers diagram pad mounted transformer manufacturers nameplate

 

 

02 Nrụpụta

2.1 Mmanụ Luminol

Luminol Oil

A na-enye mmanụ ọkụ na-arụ ọrụ Luminol dị elu-SCOTECH's pad mounted, a premium dielectric fluid inengine to but the dual core insulation: ihe mkpuchi eletrik pụrụiche nke na-egbochi mmejọ arc na ikpo ọkụ dị mma nke na-edobe okpomọkụ na-arụ ọrụ nke ọma ọbụlagodi na oke okpomọkụ nke ihu igwe Canada. Mmanụ a pụrụ iche na-agbasosi ụkpụrụ CSA siri ike, na-anya isi nkwụsi ike nke okpomọkụ na nguzogide oxidation iji zere mmebi oge akaghi aka, ma na-agbatị ndụ ọrụ nke transformer nke ukwuu ma na-ebelata ogologo oge{2}} mkpa nlekọta oge{3} na-eme ka ọ bụrụ nke a pụrụ ịdabere na ya, ọnụ ahịa- nhọrọ dị irè maka ikesa ike na-agbanwe agbanwe.

 

2.2 Ikuku

SCOTECH's pad mounters transformers na-egosi oke ikuku ọla kọpa dị ọcha{{0}, nke na-ebuga nrụpụta ọkụ eletrik dị elu, obere ike na-efunahụ ya, yana ezigbo nguzogide okpomọkụ iji guzogide mgbanwe okpomọkụ a na-ahụkarị na mpaghara ọrụ Canada. Nkenke{2}ọnya ma kpuchie ya na ihe mkpuchi dị elu, ikuku ikuku ndị a na-emezu ụkpụrụ CSA siri ike, na-ahụ na arụmọrụ a pụrụ ịdabere na ya, obere okpomọkụ na ndụ ogologo ndụ maka transformer{3} niile mgbe ọ na-akwado nkesa ike kwụsiri ike maka ngwa obibi, azụmahịa na ụlọ ọrụ mmepụta ihe.

high-purity copper winding

 

2.3 Valve mkpọpu mmanụ

Oil Drain Valve

SCOTECH's pad mounters nwere ihe nrụnye siri ike, corrosion{0}na-eguzogide brass mmanụ drain valve, na-egosipụta onye ọrụ -wheel na-acha uhie uhie enyi na enyi maka ịrụ ọrụ nke ọma yana agbụ nchekwa iji gbochie mfu akụrụngwa n'oge mmezi. Ejiri ya na ntapu{3}} akara siri ike iji nagide ọnọdụ ihu igwe siri ike nke Canada, valvụ ndị a na-agbaso ụkpụrụ CSA siri ike, na-eme ka mmiri dị mma na-achịkwa nke Luminol dielectric mmanụ n'oge ọrụ oge niile ma ọ bụ ndochi mmiri, wee hụ na a pụrụ ịdabere na ya, ogologo oge- ịrụ ọrụ ntụgharị.

 

2.4 ọla kọpa Grounding Busbar

SCOTECH's pad mounted transformers nwere nnukwu ụgbọ ala ọla kọpa siri ike dị elu- dị ọcha, arụpụtara iji weta ụzọ mmejọ dị ala{1} nke na-eme ka nchekwa eletrik bụrụ nke a pụrụ ịdabere na ya maka ma transformer na ndị ọrụ saịtị-. Nkenke -oghere nrịgo olulu na arọ- braket ọrụ na-echekwa bọsbar ahụ nke ọma na ebe nchekwa nchekwa, ebe eriri ala agbakwunyere na-emepụta njikọ eletrik na-aga n'ihu n'ofe akụrụngwa dị oke mkpa. Emepụtara ya iji zute ụkpụrụ CSA siri ike, bọsbar ọla kọpa na-eguzogide{{7} na-enye arụmọrụ na-agbanwe agbanwe ọbụlagodi na mgbanwe okpomọkụ na ọnọdụ iru mmiri nke Canada, na-echekwa akụrụngwa nkesa ike dị egwu megide mmejọ eletrik yana hụ na ogologo oge- na-arụ ọrụ.

Copper Grounding Busbar

 

2.5 Baynet Fuse

Igwe ọkụ bayonet n'ime pad{0} agbakwunyere transformer bụ ngwaọrụ nchebe nwere ike ịrụ ọrụ na mpụga nke etinyere n'ime ụlọ raara onwe ya nye. Ọ na-enwekarị katrij fuse nke mbughari nke etinyere na njide akpọchiri akpọchi, emebere maka ọrụ "ọkụ{2}osisi" dị mma site n'aka ndị ọrụ. Ọrụ ya bụ isi bụ inye ihe nchebe nke ukwuu maka transformer, na-adịkarị n'akụkụ nke mbụ, site n'ịkwụsị ikuku ọjọọ. Otu njiri mara bụ nke nwụrụ anwụ - n'ihu imewe; Enwere ike ịwepụta ma ọ bụ tinye fiusi ahụ n'enweghị nsogbu na-enweghị ikpughe akụkụ ndị dị ndụ, na-echekwa nchekwa nke ogige ahụ ọbụlagodi n'oge mmezi. Nhazi a na-enye ohere maka ikewapụ ngwa ngwa na nnọchi ubi, na-eme ka mweghachi ọrụ a pụrụ ịdabere na ya.

 

 

03 Nnwale

Nnwale voltaji etinyere bụ ule dị oke egwu dielectric a na-eme n'elu ihe ngbanwe na pad mounted iji chọpụta ike nke sistemu mkpuchi ha iji guzogide oke voltaji na-adịru nwa oge yana nrụgide ọrụ nkịtị n'enweghị nsogbu. Emere ya dị ka ụkpụrụ IEEE na CSA siri dị, ule a gụnyere ịkwupụ ikuku n'ime nke transformer na itinye voltaji a na-agbanwe agbanwe ugbu a (AC) -karịa 1.5 ruo 2 ugboro kacha elu voltaji sistemu - gaa n'obere isi na nke abụọ, yana ebe nchekwa tank, maka oge 1 nkeji.

N'oge ule ahụ, ndị nyocha na-enyocha ihe ịrịba ama nke ndakpọ mkpuchi mkpuchi, dị ka ịgba ọkụ, ọkụ ọkụ, ma ọ bụ ịrị elu na-adịghị mma nke ntanye nke ugbu a, nke ga-egosi ntụpọ dị na usoro mkpuchi. Nnwale na-aga nke ọma na-egosi na igwe nrụnye n'elu pad nwere ike iguzogide ihe omume overvoltage nwa oge (dịka ọmụmaatụ, àmụmà na-ada ma ọ bụ ịgbanye elu) na-adaghị mbà, na-eme ka ọrụ a pụrụ ịdabere na ya na ibelata ihe ize ndụ nke ọdịda ọdachi ma ọ bụ nkwụsị ọkụ na netwọk nkesa.

 

 

04 Saịtị na nchịkọta

Na SCOTECH, a na-emezi ihe ndị na-eme mgbanwe na pad anyị iji kọwapụta ntụkwasị obi, nchekwa na arụmọrụ maka mkpa nkesa ike gị. Ezubere ma nwalee na nrube isi na ụkpụrụ IEEE/CSA, nkeji ndị a na-arụ ọrụ na-agbanwe agbanwe na mpaghara obodo mepere emepe, ogige azụmahịa, mpaghara ụlọ ọrụ mmepụta ihe, na gafere{1}ọbụlagodi n'ọnọdụ ọrụ kacha achọ.

Site n'ilekwasị anya na nrụzi dị ala, obere akara ukwu, yana nguzogide ihu igwe siri ike, a na-ewu ihe mgbanaka mgbanaka pad anyị iji wedata oge ezumike wee bulie uru ogologo oge maka ọrụ gị-. Ma ị na-emelite akụrụngwa dị ugbu a ma ọ bụ na-ebuga sistemu ike ọhụrụ, SCOTECH na-eguzo dị ka onye gị na ya tụkwasịrị obi na-ebuga usoro mgbanwe mgbanwe ahaziri ahazi, dị elu{2}. Kpọtụrụ ndị otu anyị taa ka anyị kparịta ihe ị chọrọ, ma mee ka anyị nwee ike ịga nke ọma gị na ntụkwasị obi ị nwere ike ịtụkwasị obi.

 transformer solutions

 

Ihe nchịkọta dị ọkụ: Ndị na-emepụta ihe na-emepụta ihe, ndị na-emepụta ihe, ndị na-ebu ihe, ọnụahịa, ọnụ ahịa

Zipu ozi