Mpempe akwụkwọ 300 kVA{1} agbakwunyere Transformer-34.5/0.208 kV|USA 2024
Ike: 300kVA
Voltaji: 34.5GrdY/0.208kV
Njirimara: loop ndepụta

Nkwenye voltaji kwụsiri ike na arụmọrụ emelitere - nke atọ{1}} ngbanwe - nke etinyere na-eme ka ọkọnọ ọkụ dịkwuo mma!
01 Izugbe
1.1 Ihe ndabere oru ngo
300 kVA three phase pad mounted transformer e zigara China na 2024. Ike nke transformer bụ 300 kVA na ONAN jụrụ oyi. The isi voltaji bụ 34.5GrdY / 19.92 kV na ± 2 * 2.5% tapping nso (NLTC), nke abụọ voltaji bụ 0.12 / 0.208 kV, ha guzobere vector otu YNyn0.
A na-ejikarị ihe nrụnye nrụnye nke atọ na-adọba ụgbọala na nkesa ike obodo yana ngwa ụlọ ọrụ mmepụta ihe. Iji Load Break Connectors na-enye ohere maka njikọ dị mma na nkwụsị nke ike mgbe ị na-ebu ibu, na-eme ka nchekwa na ịdị mma na-arụ ọrụ dịkwuo mma. A na-ejikọta ihe ngbanwe ahụ - agbakwunyere na grid na ibu site na eriri ala. Nhazi a na-akwalite nchekwa ma na-ebelata ihe egwu ndị metụtara oke voltaji ma ọ bụ mkpirisi mkpirisi mkpirisi mkpirisi. A na-eji pad mounted transformer eme ihe n'ọtụtụ ebe na-enye ọkụ obodo, ụlọ azụmahịa, ogige obibi, na ogige ụlọ ọrụ mmepụta ihe, na-enye ike kwụsiri ike maka ngwaọrụ na akụrụngwa dị iche iche. Nhazi nke mpe mpe akwa - ihe nrụnye n'elu na-eme ka nrụzi dị mfe ma nwee usoro nchekwa dị iche iche, dị ka nchekwa oke ibu na nchekwa mkpirisi-.
1.2 Nkọwa nka nka
300 KVA ụdị nkọwa nkọwa na mpempe akwụkwọ data
|
Enyere ya
China
|
|
Afọ
2024
|
|
Ụdị
Ihe mgbakwasa na mpe mpe akwa
|
|
Ọkọlọtọ
Ụkpụrụ ANSI
|
|
Enyere ike
300 kVA
|
|
Ugboro ugboro
60HZ
|
|
Usoro
3
|
|
Nri
Loop
|
|
N'ihu
Nwụrụ anwụ
|
|
Ụdị oyi
ONAN
|
|
Voltaji nke mbụ
34.5GrdY/19.92 kV
|
|
Voltaji nke abụọ
0.12 / 0.208 kV
|
|
Ngwa ikuku
Aluminom
|
|
Ntugharị akụkụ
YNyn0
|
|
Mgbochi
5%(±7.5%)
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
±2*2.5%
|
|
Enweghị mfu ibu
0.46KW
|
|
Na Ibu Mfu
4.675KW
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
1.3 Eserese
300 kVA mpe mpe akwa akwadoro eserese eserese na nha.
![]() |
![]() |
02 Nrụpụta
2.1 Isi
Isi ihe ngbanwe bụ isi ihe dị na transformer, onye isi ọrụ ya bụ inye ụzọ ndọta dị ala- iji kwalite arụmọrụ electromagnetic nke ihe ngbanwe. Ihe mejupụtara ya bụ ọtụtụ mpempe ígwè dị mkpa, ihe a na-eme iji belata mfu na-efu ugbu a. A na-ejikarị ọla kọpa silicon mee mpempe akwụkwọ ndị a, nke nwere nnukwu ikike magnetik na ihe mkpuchi dị mma. Nhazi nke isi ihe na-agbanwe agbanwe abụghị naanị na-emetụta arụmọrụ nke transformer kamakwa ọ na-emetụta ikike na nkwụsi ike ya. N'oge a na-arụ ọrụ, isi ihe na-emepụta oghere magnetik site na mgbanwe nke ugbu a, na-enye ike nnyefe na ntụgharị.

2.2 Ikuku

Dabere na ntinye na mmepụta voltaji chọrọ nke transformer, gbakọọ ntụgharị ntụgharị maka windings nke mbụ na nke abụọ. Nhazi nke ntụgharị ntụgharị na-emetụta oke voltaji nke transformer na ntụgharị ike. Jiri igwe ikuku akpaaka iji hụ na ịdị n'otu na ịdị n'otu nke ikuku ikuku. Ọ dị mkpa iji hụ na nhazi nke winding siri ike na enweghị ngafe. Tinye ihe ndị dịpụrụ adịpụ n'etiti ọkwa dị iche iche iji hụ na arụmọrụ mkpuchi n'etiti ọkwa.
2.3 tank
A na-eji ihe igwe mee tankị mmanụ ahụ ma na-enweta ọgwụgwọ mgbochi{{0} corrosion , na elu mpụta ejiri nchara kpuchie{1}} agba na-eguzogide. Ọdịdị ya bụ akụkụ anọ, e mere iji hụ na ibu{3}} ibu na nkwụsi ike iji guzogide nrụgide gburugburu ebe obibi. A na-ejupụta tank mmanụ ahụ na mmanụ mkpuchi, nke na-eje ozi na-ajụ oyi na mkpuchi. N'oge a na-arụ ọrụ, mmanụ ahụ na-amịkọrọ okpomọkụ sitere na windings na isi, na-ekpochapụ okpomọkụ site na convection eke ma ọ bụ mmanye mgbasa. A na-emepụta tank ahụ na ihe mkpuchi dị mma iji gbochie mmetọ gburugburu ebe obibi na nsị mmanụ, ma kwadebere ya na valvụ nchekwa, ihe nrịbama nrụgide, na ngwaọrụ ndị ọzọ iji hụ na arụ ọrụ dị mma.

2.4 Mgbakọ ikpeazụ

Nkwadebe ihe mejupụtara: Gbaa mbọ hụ na ihe ndị dị mkpa dị ka isi ihe ntụgharị, windings, na tank mmanụ dị njikere.
Gwakọta tankị mmanụ: Idozi tank mmanụ a na-agwọ na-edozi ma wụnye gaskets mkpuchi iji gbochie nkwụsị mmanụ.
Wụnye Core na Windings: Debe isi ihe ntụgharị n'ime tank mmanụ ma wụnye windings, na-eme ka nhazi nke ọma na ntinye nke ọma.
Jikọọ eriri: Jikọọ eriri elu{0}voltaji na obere{1}, na-eji ihe mkpuchi iji hụ na nchekwa.
Jupụta mmanụ na ikuku: Jupụta mmanụ mmanụ na mmanụ mkpuchi, wepụ ikuku ma hụ na mma mmanụ dị mma.
03 Nnwale
(1) Nnwale oge niile
a) Ratio na njikọ na pịa ọnọdụ
b) Ntughari n'akuku
c) Mba - ibu mfu na 100% gosiri voltaji
d) Ihe na-atọ ụtọ ugbu a na voltaji 100% kwadoro
e) Ibu efu na ihe mgbochi na akara ugbu a
f) voltaji etinyere
g) voltaji na-ebute
h) Ntugharị ụgbọ mmiri transformer{0}}Nnwale nchọpụta
i) Nnwale na-aga n'ihu
(2) Ụdị ule
a) Nguzogide
b) Okpomọkụ ịrị elu
c) Ike mkpali
d) Redio{0}} voltaji mmetụta
f) Transformer iguzosi ike n'ezi ihe
g) Ụda ụda isi
h) Nrụgide na-adịghị mma na-eguzogide


04 Mbukota na mbupu


05 Saịtị na nchịkọta
Na mmechi, igwe mgbanaka{{0}phase{1} atọ a etinyegoro na-arụ ọrụ dị mkpa na sistemu nkesa eletrịkị ọgbara ọhụrụ, na-enye ntụkwasị obi na arụmọrụ na nnyefe ike. Nhazi ya siri ike yana teknụzụ dị elu na-eme ka arụ ọrụ kachasị mma na-ebelata mfu ume na mmetụta gburugburu ebe obibi. Site n'ule siri ike na usoro mmesi obi ike, a na-ewu transformers ndị a ka ha nagide ọnọdụ ndị na-achọsi ike ma na-enye ọrụ nchekwa, ntụkwasị obi na ogologo ndụ ha na-arụ ọrụ. Ka anyị na-aga n'ihu n'ịgbanwe na mkpa ume anyị, pad -phase pad - transformer na-eguzo dị ka ihe dị oke mkpa n'ịkwalite akụrụngwa ike anyị, na-akwado mgbanwe gaa na ngwọta ike na-adigide maka ọdịnihu.

Ihe nchịkọta dị ọkụ: mpe mpe akwa - ihe ngbanwe, onye nrụpụta, onye na-ebubata, ọnụahịa, ọnụ ahịa
You Might Also Like
250 kVA Pad Nkwanye Ntugharị-23 / 0.4 kV|Chile 2024
2500 kVA Pad Nkwanye Ntugharị-13.2 / 0.48 kV|Canada ...
5 MVA Pad Mount Transformers-33 / 0.48 kV|USA 2025
400 kVA Padmount Transformer-23 / 0.4 kV|Chile 2024
1250 kVA Pad Nkwanye Ntugharị-12.47 / 0.6 kV|US 2025
2500 kVA Pad Mount Transformer-12.47 / 0.48 kV|USA 2025
Zipu ozi