22 MVA 3 Ngbanwe ike nke oge-33/11 KV|South Africa 2025

22 MVA 3 Ngbanwe ike nke oge-33/11 KV|South Africa 2025

Obodo nzipu: South Africa 2025
Ike: 20/22MVA
Voltaji: 33/11kV
Njirimara: Akụkụ - ejiri AVR tinye OLTC
Zipu ozi

 

22 MVA 3 phase power transformer

Arụmọrụ dị elu{{0}20/22 MVA transformers maka South Africa, nke e wuru maka oke elu na okpomọkụ nwere ọrụ kwụsiri ike, rụọ ọrụ nke ọma na ntụkwasị obi.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

Ọrụ a gụnyere 20/22 MVA, 33/11 kV atọ-phase power transformers arụnyere n'ogo dị ihe dị ka mita 1,800 na South Africa, ebe okpomọkụ kwa afọ sitere na -10 degrees ruo +40 ogo. Ikuku dị gịrịgịrị na elu dị elu na-ebelata nrụpụta ọkụ ọkụ. Ọzọkwa, nnukwu mgbanwe okpomọkụ nwere ike ime ka mgbasawanye okpomọkụ na nkwụsịtụ, yana nrụgide ígwè ọrụ, na akụrụngwa. Ya mere, imewe ahụ aghaghị ịtụle ihe abụọ a gburugburu ebe obibi: elu elu na nnukwu mgbanwe okpomọkụ.

Ndakọrịta gburugburu

Mmetụta dị elu: IEC60076-2 na-achọ ka emelitere jụrụ oyi ma ọ bụ mbelata ibu n'ogo n'elu 1,000 mita. Ihe ngbanwe na-eji ONAN/ONAF ngwakọ jụrụ oyi, na-ejikọta mmanu mmanu na ikuku mmanye na-enyere aka iji kwalite arụmọrụ mgbanwe okpomọkụ.

Mmetụta okpomọkụ: N'ebe okpomọkụ dị elu ({0}} ogo ), ndị na-akwado ọkụ na-eme ka ikpo ọkụ na-ekpo ọkụ iji hụ na ịrị elu okpomọkụ agaghị agafe oke.

Atụmatụ atụmatụ isi

Ikike na Nju: Ike a kwadoro bụ 20/22 MVA, 20 MVA na ọnọdụ ONAN, na-abawanye ruo 22 MVA na ndị fan (ONAF maka 10% bufee). Ngwakọ jụrụ oyi na-eme ka mgbasa ọkụ zuru oke na nnukwu{6}}okpomọkụ na gburugburu elu{7}, na-ezute ikike ibu dị jụụ nke IEC multi{8}.

Ọkwa voltaji na wiring: 33 kV/11 kV, Dyn11 vector group (njikọ voltaji dị elu, njikọ Y dị ala, ebe na-anọpụ iche dabere), na-ahụ n'ihu n'ihu nguzozi nke atọ{{3} na ntinye ala chọrọ. Akụkụ abụọ ahụ na-eji mkpuchi LI200 (na-eguzogide 200 kV voltaji mkpali na 70 kV AC na-eguzogide voltaji) iji hụ na oke ala megide ike mkpuchi mkpuchi nke ikuku dielectric na elu elu.

Ihe na-ekuku na ihe mgbochi: ikuku ọla kọpa na-eme ka ikike ibu dị ugbu a na ike ibu dị mkpụmkpụ{1}, ebe mgbochi 14.29% na-amachi mmejọ ugbu a. N'oge a na-arụ ọrụ n'otu oge, akụkụ nke mbụ nwere 3{7} nke abụọ symmetrical na-eguzosi ike ugbu a nke 21 kA, akụkụ nke abụọ nwere ọnụ ọgụgụ kasị elu nke ugbu a nke 18 kA, nke nwere ike iguzogide mkparị mkpirisi mkpirisi.

Na -Iwu Ibu Voltaji: Onye kọntaktị oghere OLTC nwere ±8 × 1.25% (mkpokọta ±10%) oke ụkpụrụ voltaji. Akụkụ - agbakwunyere, ọ na-eme ka ịrụ ọrụ na mmezi ya dị mfe, na-eme ka ụkpụrụ voltaji dị larịị n'oge arụ ọrụ.

Oil Dielectric na mkpuchi: A na-eji mmanụ mkpuchi ịnweta ịnweta dị elu- nwere ike dielectric nke Karịrị ma ọ bụ nhata 80 kV, jikọtara ya na nhazi mkpuchi ọkwa dị elu{2} iji hụ na oke ọkụ na-eguzogide. Ebe dị elu na-enwe mmetụta dị nta na mkpuchi mmanụ - dabere; A na-akwụ ụgwọ nbibi mkpuchi nke ikuku dị gịrịgịrị na-akwụ ụgwọ site na nhazi bushes na oghere ikuku.

A na-eji ihe nrụnye ọkụ nke nkeji atọ a kwadebere n'ụzọ zuru oke iji hụ na arụ ọrụ nchekwa na ntụkwasị obi: akụkụ - vacuum na {{2}load tap-Changer (±8×1.25%) na onye na-ahụ maka voltaji na-akpaghị aka na-edobe nkwụsi ike voltaji; temometa larịị mmanụ na ikuku temometa na-enyocha okpomọkụ na-ebili ozugbo; elu -voltaji bushing na-enye mkpuchi a pụrụ ịdabere na ya; a desiccant na gas relay na-egbochi mmiri mmiri ma na-enye ịdọ aka ná ntị mmalite maka mmejọ nke ime; onye na-ejide ọkụ ọkụ dị elu - na-echebe akụrụngwa pụọ ​​na mmebi oke voltaji; Ihe ngbanwe 15 dị ugbu a na-akwado nha, nchedo, na ọrụ ndị yiri ya; na ihe nchekwa mmanụ agbakwunyere na-enyere aka ịhazi oke mmanụ na nchekwa, ebe ọ na-ebuli nhazi na itinye ohere.

 

 

 

1.2 Nkọwa nka nka

22 MVA 3 akụkụ ike transformer nkọwa na mpempe akwụkwọ data

Enyere ya
South Africa
Afọ
2025
Ụdị
Ihe ngbanwe ike
Ọkọlọtọ
IEC60076
Enyere ike
20/22 MVA
Ugboro ugboro
50HZ
Usoro
Atọ
Ụdị oyi
ONAN/ONAF
Ihe mgbochi mmiri
80 kV dielectric ike
Voltaji nke mbụ
33 kV
Voltaji nke abụọ
11 kV
Otu Vector
Dyn11
Ngwa ikuku
Ọla kọpa
Mmetụta @ 75 ogo
14.29%
Pịa Changer
OLTC/ Vacuum
Ọkụ aka
±8*1.25%
Enweghị mfu ibu
15 kV
Na Ọnwụ Ebu
124 kV
Ngwa ngwa
Nhazi ọkọlọtọ

 

1.3 Eserese

22 MVA 3 akụkụ ike transformer eserese na aha aha

22 MVA 3 phase power transformer drawing 22 MVA 3 phase power transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

22 MVA 3 phase power transformer iron core

A na-eme 20/22 MVA 3-phase power transformer core dị ka ISO 60076 si dị. Mpempe akwụkwọ nchara silicon dị na isi ahụ ruru ụkpụrụ maka ịrụ ọrụ eletrik na magnetik. Ha na-enye obere mfu isi na ọrụ a pụrụ ịdabere na ya. Isi mma dị elu na-ebelata ike ike dị ka okpomọkụ. Ọnwụ isi dị ala na-egbochi ikpo oke ọkụ, na-agbatị ndụ ọrụ ma na-ebelata mkpa usoro jụrụ oyi.

 

2.2 Ikuku

22 MVA 3 phase power transformer copper winding
22 MVA 3 phase power transformer winding

A na-eji ọla kọpa dị elu- rụọ eriri igwe ndị a. Ha na-agbaso iwu nhazi siri ike. Igwe ikuku dị elu -voltaji Delta nwere ike iguzogide oke oso - ruo -mkpirisi mkpirisi - iyi iyi okirikiri. Ọ nwere ike n'ibu ike. Igwe ikuku kpakpando voltaji dị ala{9} nwere nnọpụiche dabara adaba. A na-emerụ eriri igwe ọla kọpa ahụ site na nrụgide oyi akwa na-achịkwa. Nke a na-eme ka o doo anya ọbụna ugbu a na ikpo ọkụ dị mma. Igwe mkpuchi na-enye arụmọrụ a pụrụ ịdabere na ya na ogologo ndụ ọrụ.

 

2.3 Igbe njedebe

22 MVA 3 phase power transformer oil tank

22 MVA 3 phase power transformer oil tank

Ihe ntụgharị ọkụ mgbada nwere otu{{0}ibe mmanụ nchekwa mmanụ na-ejikọta mgba ọkụ na nnukwu tankị, nke kewapụrụ site na nkebi nwere ngbanwe nke etinyere n'akụkụ. Tank na-agafe ule akara 30 kPa maka awa 24 na-enweghị ọdịda. Ihe niile na akụkụ niile na-ezute eserese, na ntụgharị n'okpuru 1 mm. Efere ígwè na-agbaso ụkpụrụ mba na enweghị nrụrụ, nchara, peeling, ma ọ bụ dent. Welds kwụ ọtọ, dị larịị, edo edo na enweghị ntụpọ.

 

2.4 IP55 igbe

A na-eji efere ígwè dị 3mm mee igbe njedebe ma nwee nchebe IP55, na-eme ka usoro siri ike na iguzogide uzuzu na mmiri. Emebere ya ihe nleba anya ikuku ikuku na mmanụ maka nlebanya oge n'ezie{{3}. A na-enye ọkụ ọkụ 230V iji gbochie mmiri mmiri, nke dị mkpa ọbụna na South Africa, ebe ọtụtụ ebe akọrọ, ma ugwu ugwu, oge mmiri ozuzo, ma ọ bụ ógbè dị n'ụsọ oké osimiri nwere ike ime ka ikuku. Otu oriọna LED na-agbanye mgbe ọnụ ụzọ mepere emepe, na-enye nyocha dị mma.

22 MVA 3 phase power transformer terminal box

 

2.5 Na - Ibunye ihe ngbanwe

vacuum-type On-Load Tap Changer drawing
vacuum-type On-Load Tap Changer

Ihe ntụgharị ọkụ ọkụ nwere oghere-ụdị On-Load Tap Changer. Ọ nwere ọnọdụ mgbata 17 nwere usoro nzọụkwụ 1.25%. Oke voltaji bụ 29,700/11,000 V (-10%) ruo 36,300/11,000 V (+10%). Ọ na-enye njikwa voltaji ziri ezi n'oge mgbanwe ibu. OLTC na-arụ ọrụ na ntuziaka na akpaka mode. OLTC na-akwado ma akwụkwọ ntuziaka na ụdị akpaaka, nwere ike ịrụ ọrụ na ngwa ndị ọzọ, ma na-enye ikike njikwa anya.

 

2.6 Mgbakọ ikpeazụ

Core lamination insertion
Tap changer installation

 

Mgbe a gbakọtara isi ihe ntụgharị na windings, a na-etinye akụkụ na-arụ ọrụ na oven ihicha. Mgbe ihichachara, a na-ebuli ya ma tinye ya na tank mmanụ. Ihe ngbanwe ike nke nkeji atọ a nwere ọtụtụ ngwa na mgbakwunye na nke ọkọlọtọ, dị ka ihe na-agbanwe ihe mgbata ọkụ -, ihe ngosi okpomọkụ mmanụ, egosi okpomọkụ ikuku, Buchholz relay, fan, na otu-ihe nchekwa mmanụ. Ngwa ndị agbakwunyere gụnyere iku ume, elu{6}}voltaji ọkụ na-ejide ihe nkwado, yana ihe ngbanwe 15 dị ugbu a. Mgbe emechara ngwa niile, a na-emecha usoro mgbakọ ahụ na ntinye mmanụ na mkpuchi, njikọ eletrik na ule, na nyocha nke ọdịdị na akara.

 

 

03 Nnwale

Nnwale Ọkọlọtọ na Nnwale oge

Ụkpụrụ etinyere

• IEC 60076-1: 2011 Ndị na-agbanwe ike - Akụkụ 1: Ozuruọnụ
IEC 60076-3: 2013 ndị na-agbanwe ike - Akụkụ 3: ọkwa mkpuchi, ule dielectric na mkpochapụ mpụga na ikuku.
• IEC 60076-7:2018 Ndị na-eme mgbanwe ọkụ – Nkebi 7: Nduzi nbunye maka ịnweta{4}} ihe ntụgharị ọkụ na-emikpu mmanụ
• Ndị ọzọ na-ezo aka na iwu teknụzụ

3 phase power transformer test
3 phase power transformer fat

1. Lelee mkpuchi Core na Frame maka ndị na-agbanwe mmiri mmiri nwere mkpuchi isi ma ọ bụ Frame
2. Lelee nke Voltage Ratio na Vector Group
3. Ntụgharị mgbanwe ugbu a
4. Ntụle nke iguzogide ikuku
5. Ntụnye nke mba - ibu mfu na mba - ibu dị ugbu a
6. Nleba anya na-eguzogide voltaji
7. Ntụle nke impedance voltaji na ibu ọnwụ
8. Na -bu ndị na-agbanwe mgbata - Nnwale ọrụ
9. Nnwale voltaji etinyere (AV)
10. Ihe mkpuchi wiring inyeaka (AuxW)
11. Akara ule
12. Nnwale mmanụ

 

 

04 Mbukota na mbupu

4.1 mbukota

22 MVA 3 phase power transformer wooden package
Radiator packing

 

4.2 Mbupu

20/22 MVA three phase power transformers shipping
20/22 MVA three phase power transformers shipping

 

05 Saịtị na nchịkọta

20/22 MVA three phase power transformers to South Africa

N'afọ 2025, anyị butere igwe ngbanwe ọkụ abụọ 20/22 MVA na South Africa. Emebere ihe ngbanwe ndị a ka ọ rụọ ọrụ ntụkwasị obi n'ebe dị elu yana gafee oke okpomọkụ.

Anyị nwere ahụmahụ na ọrụ ntụgharị ọkụ eletrik ma na-enye ngwá ọrụ dị iche iche, gụnyere ihe ngbanwe ọkụ, CTs, PTs, sekit breakers, switchgear, GIS, na ndị ọzọ. Igwe ngbanwe ọkụ anyị dị elu{1} na-ahụ na a na-arụ ọrụ nke ọma na gburugburu South Africa na-achọsi ike. Kpọtụrụ anyị taa iji kparịta mkpa ngwọta ike mpaghara gị.

 

Ihe nchịkọta dị ọkụ: 3 frasi ike transformer, onye nrụpụta, soplaya, price, efu

Zipu ozi