80 MVA Nzọụkwụ Down Power Transformer-132/33 kV|South Africa 2024

80 MVA Nzọụkwụ Down Power Transformer-132/33 kV|South Africa 2024

Obodo: South Africa 2024
Ike: 50/80MVA
Voltaji: 132/33kV
Njirimara: ya na OLTC
Zipu ozi

 

 

80 MVA step down power transformer

Nrụpụta isi siri ike ma kwụsie ike{0}ihe ngbanwe anyị na-eme ka azụmahịa gị na-aga nke ọma!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

Nkeji abụọ nke 80/50MVAIhe ngbanwe ikee bupụrụ na South Africa na Julaị, 2024. Ike a kwadoro bụ 50 MVA na usoro jụrụ oyi nke ONAN. Ike ahụ ruru 80MVA mgbe ọ bụ ONAF. Voltaji bụ 132 ka 33 kV, 132 kV isi, 33 kV nke abụọ. A na-eji ihe ngbanwe abụọ a na-arụ ọrụ n'ọdụ ọkụ fotovoltaic na South Africa.

Okpomọkụ dị n'ebe mgbada mgbada ọkụ ọkụ bụ -5 degrees C ruo +45 ogo C, ogo mmetọ gburugburu ebe obibi siri ike, yana oke iru mmiri bụ 85%. Nke a na-achọ ka igbe transformer nwee ike ime mgbanwe na gburugburu ebe dị iche iche siri ike. Abụọ ahụọkara ike transformersanyị na-emepụta nwere igbe dị elu - ike, elu igbe ahụ na-anakwere mgbochi{1} corrosion imewe na ọgwụgwọ agba pụrụ iche, ọkpụrụkpụ agba dị n'elu 125mm, nke nwere ike igbochi mbuze nke ájá na ihe ndị ọzọ na-emerụ ahụ. Igwe ọkụ mgbawa nke ihe ngbanwe a na-anabata usoro pụrụ iche nke itinye galvanizing ọkụ. Na mgbakwunye, akwa mkpuchi dị elu na nke dị ala nwere eriri njide galvanized. Ekwesịrị ịchebe sekit njikwa niile nke transformer, na ebe na-anọpụ iche voltaji dị elu kwesịrị ka ala ala. Ohiri isi mmanụ ọ bụla na-abịa na ohiri isi mmanụ capsule na onye na-anakọta ihicha.

 

 

1.2 Nkọwa nka nka

80 MVA kwụpụ ike ngbanwe nkọwapụta na mpempe akwụkwọ data

Enyere ya
South Africa
Afọ
2024
Nlereanya
SFSZ-80000/132
Ụdị
OLTC Step Up Power Transformer
Ọkọlọtọ
IEC 60076
Enyere ike
80MVA
Ugboro ugboro
50HZ
Usoro
Atọ
Ụdị oyi
ONAN 50MVA / ONAF 80MVA
Voltaji dị elu
132kV
Voltaji dị ala
33kV
Ngwa ikuku
Ọla kọpa
Mgbochi
12.3%
Pịa Changer
OLTC
Ọkụ aka
±8×1.25%
Enweghị mfu ibu
42.031KW
Na Ibu Mfu
124.5KW ONAN/318kV ONAF
Ngwa ngwa
Nhazi ọkọlọtọ
Otu Vector
YNd1

 

1.3 Eserese

80 MVA gbadata eserese ihe ngbanwe ọkụ na nha.

80 MVA step down power transformer drawing 80 MVA step down power transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

Akụkụ akụkụ nke ọ bụla nke isi na-akwado mgbada mgbada ike ntụgharị ikuku, na nha na ọdịdị nke akụkụ ụkwụ ndị a haziri dabere na ike akara (80MVA) na ọkwa voltaji. Akụkụ kwụ ọtọ nke isi, nke a na-akpọ yoke, jikọtara akụkụ atọ dị n'elu na ala, na-eme sekit magnetik mechiri emechi. A na-eme isi ya bụ nke dị elu-permeability, obere oyi-oyi mfu -ọka kpọchiri akpọre -slicon steel sheets iji wedata isi mfu (gụnyere hysteresis na mfu ugbu a). Isi ụkwụ na yok na-etolite sekit magnetik mechiri emechi. A na-ekesa flux magnetik n'akụkụ akụkụ atọ ndị ahụ, na-enwe mgbanwe nke akụkụ nke ọ bụla na-agafe na yok wee jikọta ya na akụkụ abụọ ndị ọzọ, na-eme ka ngbanwe nke usoro atọ- guzozie eguzozie.

80 MVA step down power transformer steel core

 

2.2 Ikuku

80 MVA step down power transformer electrical coils

Ọnụọgụ ntụgharị, obe{0}akụkụ mpaghara nke onye nduzi, na oghere nke ngalaba ọ bụla na-adabere na ọkwa voltaji nke transformer, ikike ike na ihe achọrọ ugbu a. Ebe ọ bụ na ikuku na-aga n'ihu, a na-ekesa oghere magnetik n'otu n'otu n'ofe ikuku, na-ebelata mmetụta nke ntanye ntanye. Ntụgharị ahụ nwere oghere na-eme ka nkesa voltaji dị larịị, na-ebelata nrụgide n'etiti{3} na nsogbu mkpuchi. Nhazi siri ike nke akụkụ ikuku na-eme ka sekit magnetik mechie, na-ebelata mmeghachi omume ntanye ma na-emeziwanye arụmọrụ mgbanwe.

 

2.3 tank

1. Mgbe ọkpụrụkpụ nke efere nchara n'akụkụ igbe ahụ na-erughị 12mm, a na-eji ihe eji eme ihe na-edozi ahụ nke Q235, a na-eji igwe ọkpọ ọkụ na-ebipụ ihe ọkpụkpụ. Mgbe ọkpụrụkpụ nke efere nchara n'akụkụ igbe ahụ> 12mm, a na-eji efere ígwè nke Q235 eme ihe, a na-egbutukwa ihe ahụ site na CNC ọkụ / plasma ịkpụcha igwe.

2. A na-eme ala nke tank tank nke Q235 ígwè efere. Mgbe ọkpụrụkpụ nke efere ígwè ahụ na-erughị 14mm, a na-eji igwe ịkpụ. Mgbe ọkpụrụkpụ nke efere ígwè dị> 16mm, jiri igwe ịkpụ CNC na-egbutu ihe.

Mgbe agbakọtara mgbidi igbe ahụ, a na-eme ọgwụgwọ kemịkalụ dịka usoro OFL.140.5060 pickling phosphating si dị.

3. Ihe mkpuchi nke tankị nke na-agbanwe agbanwe bụ nke Q235 efere ígwè. Mgbe ọkpụrụkpụ nke efere ígwè ahụ na-erughị 14mm, a na-eji igwe ịkpụ. Mgbe ọkpụrụkpụ nke efere ígwè dị> 16mm, jiri igwe ịkpụ CNC na-egbutu ihe.

step down power transformer Q235 steel plate oil tank

 

2.4 Mgbakọ ikpeazụ

80 MVA step down power transformer active part
80 MVA step down power transformer assembly

 

 

03 Nnwale

80 MVA step down power transformer test
step down power transformer test

 

 

04 Mbukota na mbupu

80 MVA step down power transformer packing
80 MVA step down power transformer shipping

 

05 Saịtị na nchịkọta

Uru nke na-ekpo ọkụ itinye galvanizing

Maka mgbawa radiators maka 80 MVA gbadaa ọkụ ọkụ, usoro ịgbanye ọkụ na-ekpo ọkụ na-enye ọtụtụ uru dị mkpa:

• Nguzogide corrosion: Ngwunye galvanizing na-ekpo ọkụ na-ekpo ọkụ nwere ike igbochi nbibi nke ikuku na mmiri na metal ma melite ndụ ọrụ nke radiator, karịsịa na ebe mmiri ma ọ bụ nke na-emebi emebi.

• Yiri ngbochi: Igwe galvanized oyi akwa nwekwara ike ịbawanye nguzogide mkpuchi nke ikpo ọkụ, na-eme ka ọ ghara imebi na esemokwu anụ ahụ ma ọ bụ nkukota.

• Ndozi dị mfe: Igwe ọkụ na-ekpo ọkụ galvanized radiators chọrọ ihe fọrọ nke nta ka ọ bụrụ mmezi ọzọ, na-ebelata mkpa na ọnụ ahịa nke mmezi.

• Melite arụmọrụ ikposa ọkụ: Ọ bụ ezie na galvanizing na-ekpo ọkụ na-ekpo ọkụ na-abụkarị maka mgbochi corrosion, ọ nwere ike imeziwanye arụmọrụ ikposa ọkụ n'ụzọ na-apụtaghị ìhè site n'idebe elu nke radiator dị larịị na nchara-free.

80 MVA step down power transformers manufacturer

 