63 MVA Power Electronic Transformer-242 / 10.5 kV|South Africa 2024

63 MVA Power Electronic Transformer-242 / 10.5 kV|South Africa 2024

Obodo: South Africa 2024
Ike: 63MVA
Voltaji: 242/10.5 kV
Njirimara: ya na OLTC
Zipu ozi

 

 

63 MVA Power Electronic Transformer South Africa

Nrụpụta isi siri ike ma kwụsie ike{0}ihe ngbanwe anyị na-eme ka azụmahịa gị na-aga nke ọma!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

Ebupụrụ nkeji abụọ nke 63MVA Power transformers na South Africa na July 2024. Voltage dị 242 ruo 10.5 kV, 242 kV isi, 10.5 kV nke abụọ. A na-eji ihe ngbanwe abụọ a na-arụ ọrụ na ọdụ ọkụ fotovoltaic na South Africa.

Nke a 63MVA, 242/10.5 kV ike transformer bụ injinia dị ka isi nkuku a pụrụ ịdabere na ya nke ọma na nke dị mma maka mgbasa ozi eletriki na netwọk nkesa. Ọ na-eji nke ọma gbadata ọkụ eletrik dị elu{4} site na 242 kV ruo 10.5 kV, na-enye ọkụ kwụsiri ike ma na-aga n'ihu maka ụlọ ọrụ mmepụta ihe na grids ime obodo. Site n'ikike ya siri ike, a na-ewu ngalaba ahụ ka ọ na-arụ nnukwu ibu ka ọ na-etinye atụmatụ dị elu iji belata mfu, na-ahụ na ike dị elu, mbelata ụgwọ ọrụ yana nkwalite ịdịte aka. N'ezie, ọ na-anọchi anya ngwakọta zuru oke nke arụmọrụ siri ike yana imewe ọgụgụ isi, na-ekwe nkwa nkwụsi ike grid yana ije ozi dị ka itinye ego ntụkwasị obi maka ọdịnihu ike na-adigide.

 

 

1.2 Nkọwa nka nka

63MVA ike transformer nkọwa na akwụkwọ data

Enyere ya
South Africa
Afọ
2024
Nlereanya
SFSZ-80000/132
Ụdị
OLTC Step Up Power Transformer
Ọkọlọtọ
IEC 60076
Enyere ike
63MVA
Ugboro ugboro
50HZ
Usoro
Atọ
Ụdị oyi
ODWF
Voltaji dị elu
242KV
Voltaji dị ala
10.5KV
Ngwa ikuku
Ọla kọpa
Mgbochi
12.3%
Pịa Changer
OLTC
Ọkụ aka
±8×1.25%
Enweghị mfu ibu
42.031KW
Na Ọnwụ Ebu
124.5KW ONAN/318KV ONAF
Ngwa ngwa
Nhazi ọkọlọtọ
Otu Vector
YNd1

 

1.3 Eserese

63MVA ike eletrọnịkị ihe eserese eserese na nha.

63MVA power electronic transformer diagram power electronic transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

Isi nke 63MVA, 242/10.5 kV transformer bụ nkenke{3}}wuru site na iji obere mfu{4}}, oyi -ọka akpọre akpọre -Slicon steel. Ọ na-egosipụta usoro nhazi ọkwa kachasị mma -nke na-ebelata ike ndọta ma na-ebelata nnukwu mfu (enweghị-mfu ibu). Nke a na-eme ka arụmọrụ dị elu, ọnụ ahịa ọrụ dị ala, yana arụ ọrụ dị jụụ, ntụkwasị obi n'okpuru ọrụ na-aga n'ihu.

63MVA power electronic transformer core

 

2.2 Ikuku

63MVA power electronic transformer electrical coils

Ihe ngbanwe a na-eji ihe nrụnye diski na-aga n'ihu, nke ama ama maka ike ọrụ ya pụrụiche iji guzogide ike mkpirisi-. Ihe owuwu a siri ike, nke emere site na onye nduzi akụkụ anọ mkpuchi mkpuchi n'ime usoro diski ejikọtara ọnụ, na-eme ka mgbasa ọkụ dị mma yana ntụkwasị obi, ogologo oge-. Ọdịdị monolithic na-enweghị nkwonkwo na-enye nkwụsi ike eletrik na arụmọrụ pụtara ìhè.

 

2.3 tank

A na-arụ tankị nke 63MVA, 242/10.5 kV ike transformer site na efere ígwè siri ike, nke na-egosipụta akụkụ corrugated ma ọ bụ nku jụrụ oyi maka ịgbasa ọkụ dị mma site na elu elu. Nhazi ya nke ejiri mechiri emechi na-eme ka a mata ikewapụ oke mmiri na ikuku oxygen, na-echekwa iguzosi ike n'ezi ihe nke mmanụ. Ejiri ngwa ngwa ọkọlọtọ gụnyere nchekwa nchekwa, nrụgide - ngwaọrụ mwepụta, yana nleba anya, tank ahụ na-enye ebe nchekwa na nchekwa maka isi na ikuku, na-ekwe nkwa ogologo oge- ntụkwasị obi n'okpuru ihe arụ ọrụ na-aga n'ihu.

Q235 steel plate oil tank

 

2.4 Mgbakọ ikpeazụ

power electronic transformer active part
power electronic transformer assembly

 

 

03 Nnwale

power electronic transformer fat
power electronic transformer factory testing

 

 

04 Mbukota na mbupu

4.1 mbukota

power electronic transformer packing

 

4.2 Mbupu

power electronic transformer shipping

 

05 Saịtị na nchịkọta

The tank nke 63MVA, 242/10.5 kV ike transformer si otú na-anọchi anya dị oké egwu interface n'etiti unit si n'ime kacha mma na mpụga ọrụ ọnọdụ. Ihe owuwu ya siri ike, sistemu njikwa ọkụ na-arụ ọrụ nke ọma, yana mkpuchi hermetic na-arụkọ ọrụ ọnụ iji mepụta ebe nchekwa kwụsiri ike maka isi na ikuku. Nke a na-eme ka ihe nrụzi nke ihe ngbanwe n'okpuru nrụgide electromagnetic na-ejigide ike dielectric nke mmanụ mkpuchi n'ime ogologo oge. N'ikpeazụ, tank ahụ abụghị naanị akpa kama ọ bụ nkwa ntọala nke ntụkwasị obi na-arụ ọrụ nke transformer, nchekwa na ogologo ndụ ọrụ, na-eme ka ọrụ ya sie ike dị ka ihe a pụrụ ịdabere na ya na akụrụngwa ike.

power electronic step down transformer

 

Ihe nchịkọta dị ọkụ: 63 MVA Power Electronic Transformer-242 / 10.5 kV|South Africa 2024, China 63 MVA Power Electronic Transformer-242 / 10.5 kV|Ndị na-emepụta South Africa 2024, ndị na-ebu, ụlọ ọrụ

Zipu ozi