25 KVA Single Pole Transformer-14.4 / 0.12 * 0.24 KV|Canada 2025

25 KVA Single Pole Transformer-14.4 / 0.12 * 0.24 KV|Canada 2025

Obodo nzipu: Canada 2025
Ike: 25kVA
Voltaji: 14.4-0.12/0.24kV
Njirimara: Voltaji abụọ & Nchekwa IFD
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-eweta 25 kva single pole transformer-14.4/0.12*0.24 kv|Canada 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

25 kVA single pole transformer

SCOTECH - onye na-emepụta ihe na-ebupụta ihe na-ebu ihe 25 kVA nwere ike ịdabere na ya

 

 

01 Izugbe

1.1 Nkọwa oru ngo

Otu 25 kVA Single-Phase Pole Mounted Transformer sitere na SCOTECH dị mfe ịwụnye n'elu okporo osisi akụrụngwa. Ọ bụ nnọọ ntụkwasị obi na-abịa na mkpa ngwa. Ogwe osisi - agbakwunyere nkeji dị ka nke a dị mma maka ime obodo ma ọ bụ ebe nwere ahịrị elu. Ha dị mfe ịwụnye, dị mfe idowe, yana ọnụ ahịa{6}} dị irè maka obodo ndị dị obere-.

Ihe ngbanwe a na-agbadata elu - ọkụ eletrik (24,940 GRDY/14,400 V) gaa na mmepụta 120/240 V dị mma maka ụlọ na obere azụmaahịa na netwọk 60 Hz. Ọ nwere aluminom windings na a laminated ígwè isi. Ịrụ ọrụ karịrị 98.87% ma ọ bụ hà nhata, na-enweghị -ibu efu nke 85 W yana mfu nke 254 W. Nkwụsị ya bụ 1.97% (± 10%), na-eme ka voltaji kwụsie ike n'okpuru ibu.

Ọ gụnyere ihe na-adịghị{{0}Load Tap Changer (NLTC) nwere oke mgbatụ ±2×2.5% maka mmezi voltaji. Ihe njide voltaji 18kV - na-echebe ihe ngbanwe site na oke voltaji na ọkụ ọkụ. Ngalaba ahụ na-eji ONAN jụrụ oyi na mkpuchi mmanụ ịnweta mmanụ, yana tank mechiri emechi maka ịrụ ọrụ n'èzí a pụrụ ịdabere na ya. Ihe ngbanwe ahụ na-eji ONAN jụrụ oyi na mkpuchi mmanụ ịnweta mmanụ, yana njikwa tank mechiri emechi maka ịrụ ọrụ n'èzí a pụrụ ịdabere na ya. Enwere ike itinye ya n'ụzọ dị mfe na ogwe osisi ma ọ bụ ihe eji eme ihe, na-achọ nhazi ntakịrị.

Kwesịrị ekwesị maka mpaghara obibi, ugbo, na obere ụlọ ọrụ azụmahịa, ihe ngbanwe a na-enye ike a pụrụ ịdabere na ya na netwọk nkesa ime obodo na nke ime obodo, mgbasa ozi netwọk, na mpaghara ndị nwere ike ịwa ma ọ bụ ihe ọkụ ọkụ.

 

 

 

1.2 Nkọwa nka nka

25kVA otu osisi ntụgharị nkọwapụta na mpempe akwụkwọ data

Enyere ya
Canada
Afọ
2025
Ụdị
Mkpanaka n'agbanyeghi
Ọkọlọtọ
CSAC2.2-06/C802.1-23
Enyere ike
25KVA
Ugboro ugboro
60HZ
Polarity
Ihe mgbakwunye
Usoro
Naanị otu
Ụdị oyi
ONAN
Ihe mgbochi mmiri
Mineral Mmanụ
Voltaji nke mbụ
24940GRDY/14400 V
Voltaji nke abụọ
120/240 V
Otu Vector
Ii6
Ngwa ikuku
Aluminom
Mgbochi
1.97%(±10%)
Ịrụ ọrụ na mfu Ọkọlọtọ
Karịrị ma ọ bụ hà nhata 98.87%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
85 W
Ibu Mfu na Voltaji akwadoro
254 W
Ngwa ngwa
18kV HV onye njide

 

1.3 Eserese

25kVA otu pole transformer eserese na aha aha

25 kVA single pole transformer drawing 25 kVA single pole transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

25 kVA single pole transformer iron core

Obi nke okporo osisi - mgbanaka mgbanaka bụ isi magnetik ya, nke a na-ejikarị akwa nchara dị mkpa. Isi ihe na-enyere ike ndọta aka ịkwaga n'ụzọ dị mfe n'etiti ikuku nke isi na nke abụọ. Nke a na-enye ohere ka transformer na-enye voltaji kwụ ọtọ na obere ume na-efu ma na-arụ ọrụ ntụkwasị obi kwa ụbọchị.

 

2.2 Ikuku

Ihe ngbanwe ndị a nwere foil aluminum maka akụkụ voltaji dị ala{{0}. A na-eji waya ọla kọpa maka akụkụ voltaji {{2} dị elu. Ụlọ ọrụ mmepụta ihe na-eji ígwè ọrụ raara onwe ya nye na ndị ọrụ zụrụ azụ na-eji usoro abụọ ahụ eme ihe. Anyị na-anwale mkpuchi, nha, na nguzogide maka eriri igwe ọ bụla iji jide n'aka na nkeji ọ bụla na-arụ ọrụ dịka emebere ya.

25 kVA single pole transformer coil

 

2.3 tank

25 kVA single pole transformer oil tank

Ahụ tankị, mkpuchi, na ihe niile welded mpụga na-enweta ọgwụgwọ mgbochi - mgbe ịgbado ọkụ ga-adaba n'èzí, iru mmiri, n'ụsọ oké osimiri, na gburugburu ebe ndị ọzọ na-enwekarị nrụrụ ma ọ bụ ịgba nnu. Usoro a na-eme ka a hụ na onye ntụgharị ahụ nwere ike ịrụ ọrụ nke ọma ruo ogologo oge, ọbụlagodi na mpaghara ikuku siri ike na oke iru mmiri.

 

 

03 Nnwale

25 kVA single pole transformer testing-1
25 kVA single pole transformer testing-2

 

 

04 Mbukota na njem

4.1 mbukota

25 kVA single pole transformerpacking-1
25 kVA single pole transformerpacking-2

 

4.2 Mbupu

25 kVA single pole transformer shipping-1
25 kVA single pole transformer shipping-2

 

 

05 Atụmatụ nchekwa na nlekọta

25 kVA single pole transformer
 

Ọbụlagodi na gburugburu oke mmiri dị n'ụsọ osimiri, okporo osisi{0} rịgoro n'elu igwe ka bụ ndị a pụrụ ịdabere na ya, mana nyocha oge niile dị mkpa. Nnụnụ juru-ikuku, oke mmiri ozuzo, na ice oyi nwere ike mee ka corrosion dịkwuo elu ma ọ bụ mepụta nrụgide n'ọrụ. Isi ihe egwu gụnyere:
• Mmanụ na-agbapụta
• Àmụmà{0}} butere ọdịda
• Ibufe ibu n'oge mgbụsị akwụkwọ chọrọ spikes
Iji belata ihe egwu ịrị elu, ụlọ ọrụ na-adaberekarị na sensọ thermal na nyocha drone iji nyochaa ọnọdụ mgbanwe site na ala.

 

Ihe nchịkọta dị ọkụ: otu pole transformer, emeputa, soplaya, price, efu