Mgbasa mmanụ na-agagharị maka pad na-enye mgbanwe: Onye nlekọta a pụrụ ịtụkwasị obi maka Smart Crids

Sep 17, 2025

Hapụ ozi

Kedu ihe bụ ọkwa mmanụ maka ụlọ America {{0} pịnye ihe?

 

Ọkwa mmanụ dị elu maka pad na-agbanwe agbanwe bụ ihe eji emepụta mmiri na-eleba anya na ntanetị. Oge ọrụ ya bụ iji gosipụta ọkwa mmanụ na tank transforter na ezigbo - oge, na-eme ka ọrụ na-arụ ọrụ na-enyocha ọkwa arụmọrụ ngwa ngwa na-egbochi oke ọkwa site na ọkwa mmanụ.

 

oil level gauge

 

Uru Uru

 

1. Ezi ncheba na arụmọrụ kachasị elu

Ọnọdụ ọkwa mmanụ na-ahụ maka magnetic na-ese ihe nwere nnukwu nghọta, na-egosipụta nke ọma ọbụna obere mgbanwe na ọkwa mmanụ.

 

2.. Na-adịgide adịgide maka gburugburu

Onwere ike mgbochi na mgbochi siri ike na mgbochi na-arụ ọrụ dị mma na ọnọdụ okpomọkụ sitere na -40 ogo ogo, na-eme ya kwesịrị ekwesị maka ọnọdụ ndị siri ike.

 

3. Onye siri ike maka nchekwa nchekwa

Ọkwa mmanụ ga-eme na-ewepụta ihe owuwu nke ọma nke na-eji mmanụ transforner site na gburugburu ebe obibi, na-egbochi mmerụ mmiri ma ọ bụ gbadata nke ọma.

 

4. Ihe nrụnye dị mfe na mmezi
Ngwaọrụ ahụ na-akwado nrụnye kwụ ọtọ na-enweghị usoro dị mgbagwoju anya, na-ahụ maka mmezi dị mfe ma dịkwa mma mgbe ị na-ebelata arụmọrụ arụmọrụ.

 

oil level gauge diagram

 

Ụkpụrụ na-arụ ọrụ na nhazi

 

Ọkwa mmanụ mmanụ na-ahụ maka ihe bụ isi ihe mejupụtara ya, na-ejikọ ma na-ejikọ magneti, magnetik, na egosi. Iwu ọrụ ya bụ ihe dị ka ndị a:

1. Ọkwa mmanụ

Dị ka ọnọdụ okpomọkụ na-agbanwe agbanwe, ọkwa mmanụ dị na ososụhọ ahụ na-ebili ma ọ bụ daa nke ọma. Mgbanwe ndị a na-anya ụgbọ mmiri na-ese n'elu mmiri mmanụ iji bulie ma ọ bụ ala.

 

2.. Ihe ngosi ihe ngosi

Mmegharị nke mmiri na-agbaze ndọta nzacha site na ijikọ magneting, nke agbanwee mkpọsa ahụ na gauge iji gosipụta ezigbo {0} oge ọkwa mmanụ.

 

3. Ntinye aka

Ebumnuche ahụ na-ahụ anya nkewapụ na nkewa na ihe ngosi site na onye na-ejide ya, na-ekwe nkwa akara akara na igbochi mmanụ ọkụ.

 

oil level indicator

 

Ojiji na-akpachapụ anya

 

1. Nchedo nrụnye

A ga-echebe ọkwa mmanụ dị iche iche site na mmetụta n'oge njem na nrụnye iji zere imebi ihe owuwu ya.

 

2. Njikọ Nlekọta Lever

Enweghi ike ịgbatị ma ọ bụ guzosie ike, dịka nke a nwere ike imetụta mmetụta na izi ezi nke mmanụ ọkwa mmanụ.

 

3. Ntinye akara

Mgbanaka akara na-egbochi mmanụ ụgbọ mmiri site na tank. Ọ bụrụ nfe na-eme, lelee ma kposara ndị ahụ ka akwadoro ma ọ bụ na-akpọtụrụ n'etiti sub {{1} panel na akara mgbanaka dị larịị.

 

Ngwa dị irè

 

Ọdịda mmanụ dị larịị, nke a maara maka ntụkwasị obi na ịdịgide ya, abụrụla akụrụngwa dị oke mkpa na arụmọrụ na mmezi. Ọ na-eme ka nchekwa ọrụ ma na-ebelata ihe ize ndụ nke ọdịda akụrụngwa n'ihi ọkpọgharị mmanụ ma ọ bụ obere mmanụ.

Iji echichi na mmezi ya na mmezi ya na-adịkarị, ọkwa mmanụ transger dị iche iche ga-agbanwe agbanwe ma na-agbatịkwu ndị na-agbanwe agbanwe ma hụ na ọrụ arụmọrụ nke arụmọrụ.

 

Zipu ozi