630 kVA Ụdị Akọrọ Ike Transformer-11 / 0.55 kV|South Africa 2024

630 kVA Ụdị Akọrọ Ike Transformer-11 / 0.55 kV|South Africa 2024

Obodo: America 2024
Ike: 630 kVA
Voltaji: 11/0.55kV
Njirimara: ya na njikwa okpomọkụ
Zipu ozi

 

 

630 kVA dry type power transformer

Gaa akwụkwọ ndụ akwụkwọ ndụ, nọrọ na nchekwa: Ụdị ntụgharị ikuku nke mmeghe anyị na-enye Eco{0} enyi na enyi yana ngwọta ike dị nchebe!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

630 kVA oghere winding winding type transformer ka ebugara South Africa na 2024; ike nke ihe ntụgharị bụ 630 kVA. Isi voltaji nke transformer bụ 11 kV na voltaji nke abụọ bụ 0.55 kV. SCOTECH nke na-emepe ikuku winding ụdịdị akọrọ nwere njiri mara nke siri ike dị mkpụmkpụ{7}} nguzogide okirikiri, obere ọrụ mmezi, arụmọrụ dị elu, obere nha, mkpọtụ dị ala, a na-ejikwa ya n'ebe nwere nnukwu ọrụ achọrọ dị ka mgbochi ọkụ na mgbochi mgbawa. Nchekwa, enweghị ọkụ, enweghị mmetọ, enwere ike rụọ ọrụ ozugbo na ike ibu dị elu. Ngwaahịa a bụ klaasị H, ihe mkpuchi bụ klaasị C, mkpirisi nguzogide okirikiri siri ike, yana arụmọrụ nchekwa dị elu. Ọmarịcha mkpọsa ọkụ, ikike ibufe ibu siri ike, obere{12}}oge super{13}}ike ọrụ n'okpuru mmanye ikuku jụrụ oyi. Ọdịmma dị elu na nnukwu ikike silicon steel, ọtụtụ{15}}usoro nzọụkwụ, mbelata mkpọtụ bass, enweghị obere mfu{16}}. SCOTECH na-emepụta ihe ngbanwe ikuku na-emepe emepe nwere ụdị mgbanwe ihu igwe siri ike, mmiri mmiri, ịgba nnu na nguzogide corrosion, nguzogide ihu igwe siri ike yana ogologo ndụ ọrụ. Iji teknụzụ dị iche iche, kpochapụ ọdịnaya kwekọrọ nke ọma, yochaa nkwekọ, na ịgbatị ndụ moto.

Ejiri teknụzụ dị elu mee ihe dị 630 kVA oghere winding ụdị akọrọ wee nabata ihe dị elu na akụrụngwa, nke na-ebute ogo a pụrụ ịdabere na ya na ogologo oge ọrụ.

Anyị na-ahụ na nke ọ bụla n'ime ngalaba anyị ewepụtara enwetala ule nnabata zuru oke. Anyị na-enye otu ọrụ ngwungwu {{1} site na nyocha, nhota okwu, nrụpụta, nrụnye, inye ọrụ, ọzụzụ ruo mgbe-ọrụ ire ere. Ngwaahịa anyị na-arụ ọrụ ugbu a karịa mba 50 n'ụwa. Anyị bu n'obi ịbụ onye na-ebubata gị ntụkwasị obi yana onye mmekọ kacha mma na azụmaahịa!

 

1.2 Nkọwa nka nka

630 kVA oghere winding akọrọ ụdị mgbanwe nkọwa na data mpempe akwụkwọ

Enyere ya
South Africa
Afọ
2024
Nlereanya
630kVA-11/0.55kV
Ụdị
Na-emeghe winding akọrọ ụdị transformer
Ọkọlọtọ
IEC60076
Enyere ike
630kVA
Ugboro ugboro
50HZ
Usoro
3
Ụdị oyi
AN/AF
Voltaji nke mbụ
11kV
Voltaji nke abụọ
0.55kV
Ngwa ikuku
Aluminom
Mgbochi
6%
Pịa Changer
NLTC
Ọkụ aka
± 2 * 2.5% @ akụkụ mbụ
Enweghị mfu ibu
1.1KW
Na Ọnwụ Ebu
8.3KW
Ngwa ngwa
Nhazi ọkọlọtọ
Ọkwa mkpuchi
H
Isi ọkụ ọkụ na-anagide voltaji - akụkụ isi (BIL)
75kV
Ugboro ike na-anagide voltaji{0}}akụkụ isi
35kV
Isi ọkụ ọkụ na-eguzogide voltaji - akụkụ nke abụọ (BIL)
/
Ugboro ike na-anagide voltaji{0}} akụkụ nke abụọ
3kV
Igwe ọkụ na-ebilite @ ọnọdụ ọrụ akwadoro
100K

 

1.3 Eserese

630 kVA oghere winding akọrọ ụdị ihe eserese eserese na nha.

630 kVA opening winding dry type transformer drawing

 

 

02 Nrụpụta

2.1 Isi

Ọrụ nke dry transformer core bụ ịmepụta sekit magnetik. Iji belata mfu ugbu a, a na-eji mpempe silicon ígwè dị mkpa mee isi ya. A na-ekpuchi elu nke mpempe akwụkwọ ígwè silicon na agba mkpuchi na oxidized iji mepụta oyi akwa mkpuchi. Isi ihe mejupụtara ahụ bụ isi igwe, ihe nkpuchi na akụkụ mkpuchi. Isi isi na-anakwere usoro nzọụkwụ ọtụtụ{4} site na nhazi nhazi isi. N'okpuru ọnọdụ ọrụ dị iche iche, isi enweghị ntụgharị ntụgharị na ogologo oge.

630 kVA dry type power transformer iron core

 

2.2 Ikuku

630 kVA dry type power transformer winding

A na-eji igwe anaghị agba ọkụ klas H enamelled winding nke transformer, nke nwere ọmarịcha arụmọrụ na ikpo ọkụ, ma hazie ya nke ọma na nke ọma. Mgbe ị na-ekugharị, a na-eji cylindrical winding, na obere ikuku - voltaji dị nso na isi ka ikpuchi ya na isi. A na-emechi ikuku voltaji dị elu na mpụga ikuku voltaji dị ala. Igwe ikuku na-abụkarị nke cascading ma ọ bụ ihe owuwu helical iji belata ntapu magnetik ma melite arụmọrụ nke ngbanwe. Ntugharị nke oghere ikuku na-emeghe ụdị akọrọ anaghị ejedebe site na shei mechiri emechi ma nwee ike ịgbasa okpomọkụ n'enweghị ihe ọ bụla na ikuku, ya mere arụmọrụ ikpo ọkụ ya dị mma. Nhazi a dị mma maka iji ya mee ihe na ebe okpomọkụ dị elu ma ọ bụ ọnọdụ ikuku ventilation ka mma.

 

2.3 Mgbakọ ikpeazụ

Ọgwụgwọ mkpuchi: Tinye ihe mkpuchi ma lelee iguzosi ike n'ezi ihe nke mkpuchi ahụ.

Wiring: Wụnye ọnụ ma jikọọ wires nke ọma.

Mgbakọ Ụlọ: Wụnye ụlọ ahụ ma hụ na akara nke ọma.

630 kVA dry type power transformer assembly

 

 

03 Nnwale

Mba.

Nwale ihe

Nkeji

Ụkpụrụ nnabata

Ụkpụrụ ndị atụtara

Mmechi

1

Ntụle nke winding iguzogide

/

Ọnụego enweghị nguzozi kacha nguzogide

Nguzogide ahịrị: Ihe na-erughị ma ọ bụ haha ​​2%

HV (akara)

LV (akara)

Gafe

0.26%

0.65%

2

Ntụle nke oke voltaji na nlele nke mbugharị oge

/

Nkwenye nke oke voltaji na ọpịpị bụ isi: ± 1/10

Akara njikọ: Dyn11

-0.05% ~ 0.14%

Dyn11

Gafe

3

Ntụnye nke Mkpirisi-Mkpirisi okirikiri na mfu ibu

/

kW

kW

t:120 ogo

Z%: uru tụrụ

Pk: uru tụrụ

Pt: uru tụrụ

6.14%

5.59

7.243

Gafe

4

Ntụle nke mba- ibu mfu na ugbu a na 90% na 110% nke voltaji e gosiri

/

kW

I0:: nye uru a tụrụ atụ

P0: nye uru a tụrụ atụ

90% Uru

110% Ur

Gafe

0.342%

0.418%

0.951

1.162

5

Nnwale voltaji etinyere

/

HV: 35kV 60s

LV: 3kV 60s

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

6

Nnwale Nkwụghachi Voltaji butere

/

Voltaji etinyere (kV):

2 Ua

Voltaji ebutere (kV): 1.1

Ogologo oge (s):40

Ugboro (HZ): 150

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

7

Nnwale mgbapu akụkụ

pC

Ọkwa kacha nke mwepu akụkụ ga-abụ 10 pC

<10

Gafe

 

630 kVA dry type power transformer testing
630 kVA dry type power transformer test

 

 

04 Mbukota na mbupu

630 kVA dry type power transformer packing
630 kVA dry type power transformer shipping

 

05 Saịtị na nchịkọta

N'ebe dị oke egwu nke nnyefe na nkesa ike, oghere ikuku na-ekpo ọkụ na-emepe emepe aghọwo ihe dị mkpa nke usoro ike ọgbara ọhụrụ n'ihi arụmọrụ ya na ntụkwasị obi ya. Anyị na-agba mbọ ịnye ndị ahịa anyị ihe ntụgharị ụdị ọkụ ọkụ dị elu{1}, na-ahụ na iji ume na-arụ ọrụ nke ọma na ọrụ nchekwa. Ma na ụlọ ọrụ mmepụta ihe, azụmahịa, ma ọ bụ ebe obibi ngwa, anyị oghere winding akọrọ ụdị transformers ga-enye gị kwụsiri ike na ntụkwasị obi ngwọta. Ịhọrọ ngwaahịa anyị pụtara ịhọrọ ezigbo mma na ọrụ dị elu. Daalụ maka ntụkwasị obi na nkwado gị; anyị na-atụ anya ịrụkọ ọrụ ọnụ iji mepụta ọdịnihu dị mma.

630 kVA opening winding dry type power transformer

 

Ihe nchịkọta dị ọkụ: akọrọ ụdị ike transformer, emeputa, soplaya, price, efu