630 kVA Akọrọ Ụdị Nzọụkwụ Down Transformer-11 / 0.55 kV|South Africa 2024
Ike: 630kVA
Voltaji: 11/0.55kV
Njirimara: ya na njikwa okpomọkụ

Ntugharị dị mma, nrụzi dị ala{0}VPI Dry{1}}Ụdị ntụgharị ị nwere ike ịtụkwasị obi.
01 Izugbe
1.1 Ihe ndabere oru ngo
The 630 kVA oghere winding akọrọ ụdị transformer e nyefere South Africa na 2024. The gosiri ike nke oghere winding akọrọ ụdị transformer bụ 630 kVA na AN / AF jụrụ, isi voltaji bụ 11 kV na ± 2 * 2.5% tapping nso (NLTC), nke abụọ voltaji bụ 0.55kV, ha guzobere a vector otu.
Nhazi nkedo resin na-ejughi eriri enyo nwere ike nweta otu ike ugboro yana ọkwa mmetụta dị ka igwe ngbanwe mmanụ - imikpu. Ụdị ihe nkedo a enwewo ike iguzogide voltaji ule (oke voltaji ruo elu voltaji, elu voltaji na obere voltaji na ala) na voltaji na-arụ ọrụ na gburugburu ikuku. Enwere naanị obere nrụgide dị n'etiti ntụgharị, n'ígwé na akụkụ nke ikuku ikuku, nke resin n'onwe ya na-ebu ma rute ọkwa dị oke nchebe. Voltage dị n'etiti n'ígwé nke foil-ọnya winding bụ naanị obere voltaji kwa n'otu ntabi anya, njedebe ikuku enweghị akụkụ okirikiri, ebe ndọta ndọta dị obere, yana mkpirisi axial - mgbaka okirikiri siri ike.
1.2 Nkọwa nka nka
630 kVA akọrọ ụdị ntụgharị nkọwapụta na mpempe akwụkwọ data
|
Enyere ya
South Africa
|
|
Afọ
2024
|
|
Nlereanya
630kVA-11/0.55kV
|
|
Ụdị
Na-emeghe winding akọrọ ụdị transformer
|
|
Ọkọlọtọ
IEC60076
|
|
Enyere ike
630kVA
|
|
Ugboro ugboro
50HZ
|
|
Usoro
3
|
|
Ụdị oyi
AN/AF
|
|
Voltaji nke mbụ
11kV
|
|
Voltaji nke abụọ
0,55 kV
|
|
Ngwa ikuku
Aluminom
|
|
Fans jụrụ oyi
Awụnyere na ala nke mmalite/nkwụsị ngbanwe nke onye njikwa okpomọkụ na-achịkwa, voltaji ọkụ ọkụ 110V
|
|
Mgbochi
6%
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
± 2 * 2.5% @ akụkụ mbụ
|
|
Enweghị mfu ibu
1.25KW
|
|
Na Ibu Mfu
6.5KW
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
|
Ọkwa mkpuchi
H
|
|
Isi ọkụ ọkụ na-anagide voltaji - akụkụ isi (BIL)
75kV
|
|
Ugboro ike na-anagide voltaji{0}}akụkụ isi
35 kV
|
|
Isi ọkụ ọkụ na-eguzogide voltaji - akụkụ nke abụọ (BIL)
/
|
|
Ugboro ike na-anagide voltaji{0}} akụkụ nke abụọ
3 kV
|
|
Igwe ọkụ na-ebilite @ ọnọdụ ọrụ akwadoro
100K
|
1.3 Eserese
630 kVA oghere winding akọrọ ụdị ihe eserese eserese na nha.

02 Nrụpụta
2.1 Isi
Ọrụ nke isi ihe ngbanwe akọrọ bụ ịmepụta sekit magnetik. Iji belata mfu nke ugbu a, a na-eme isi ya nke obere mpempe silicon ígwè dị mkpa. A na-ekpuchi elu nke mpempe akwụkwọ ígwè silicon na agba mkpuchi na oxidized iji mepụta oyi akwa mkpuchi. Isi ihe mejupụtara ahụ bụ isi bụ iron, fasteners na insulating akụkụ.
Ihe nkpuchi na akụkụ mkpuchi bụ ihe nkedo, ịghasa, teepu na-ejikọta iko, teepu na-ejikọta ígwè, pad na mkpuchi mkpuchi, mkpuchi mkpuchi na mkpuchi mkpuchi, ala lug na ụkwụ.

2.2 Ikuku

Ihe nkedo oghere nwere ike nweta usoro mkpuchi otu, wepụ afụ na ihe efu, ma zere mwepu akụkụ n'ime ikuku: foil winding n'etiti elu voltaji dị ala, agaghị ebute mpụpụ akụkụ. Dị ka IEC60076 si kwuo, a ga-eme ule mwepu nke akụkụ na transformer zuru ezu. Iji gosi na imewe na mmepụta nwere ọkwa dị elu, a na-eme ule nkwụsịtụ n'akụkụ ọ bụla nke ikuku voltaji dị elu tupu mgbakọ. N'ụzọ dị otú a, ị nwere ike ịlele ma mkpuchi na ikuku ikuku dị elu na-emezu ihe ndị a chọrọ. Voltaji nkwụsị nkwụsị nke akụkụ ahụ bụ ma ọ dịkarịa ala 1.2 ugboro voltaji a kwadoro, na n'ọtụtụ ọnọdụ, ọbụna ruo ugboro abụọ nke voltaji e gosiri. Site n'ule a, egosipụtara na ọ dịghị nsogbu ọ bụla n'ife ikuku n'ime mpaghara.
2.3 Usoro njikwa okpomọkụ
1. Ewuru{1} n'ime nyocha PT100 na 3- windings nke oge iji chọpụta ọnọdụ okpomọkụ nke ikuku ikuku na ihe ngosi okirikiri na ihuenyo dijitalụ.
2. Circuit mepere mkpu na mmejọ nlele oti mkpu na mmepụta
3. 3- omume:
a. Mgbe okpomoku ahụ rutere n'ọnụ ahịa a tọhapụrụ, ndị na-ekpo ọkụ na-amalite na-akpaghị aka na ọkwa nke mbụ
b. Oti mkpu okpomọkụ dị elu na ọkwa nke abụọ
c. N'ime njem okpomọkụ na ọkwa nke atọ
4. Fan ntuziaka / akpaaka njikwa mgba ọkụ
5. Fans oge mmalite / kwụsị
6. Ndekọ data akụkọ ihe mere eme na mmepụta
7. Ọkụ ọkụ ọkụ 110V

2.4 Mgbakọ ikpeazụ

Usoro mgbakọ
1. Ngwakọta akụrụngwa: Nke mbụ, mgbakọ nke akụrụngwa, gụnyere mgbakọ nke isi, isolator, winding, wdg.
2. Kpebie ebe ngwaọrụ dị: Kpebie ebe ngwaọrụ dị ka ihe achọrọ n'ezie iji hụ na enwere ike ikpokọta ngwaọrụ ahụ nke ọma.
3. Kwadebe akụkụ njikọ: Iji hụ na arụ ọrụ nkịtị nke akụrụngwa dum, ọ dị mkpa ịkwadebe ụdị njikọ dị iche iche tupu oge eruo, gụnyere gaskets, bolts, washers, spring gaskets, wdg.
4. Kpọkọtanụ onye na-akpachapụ anya: Nke mbụ, kpọkọta onye na-akpachapụ anya, gụnyere mgbakọ nke etiti etiti, ihe mkpuchi mkpuchi, efere dịpụrụ adịpụ, onye nkesa, wdg.
5. Kpọkọtanụ winding: Wụnye winding n'ime ihe dịpụrụ adịpụ, ma ṅaa ntị n'ịdị mma nke ihe mkpuchi ahụ, yana njikwa ziri ezi nke ogologo ikuku, obe{1}} mpaghara mpaghara na paramita ndị ọzọ.
6. Wụnye njikọ: Jikọọ ngwaọrụ dị ka njikọ njikere iji dozie ma chebe ngwaọrụ ahụ.
7. Ngwọta mkpuchi: Iji hụ na arụ ọrụ dị mma nke akụrụngwa, ọ dị mkpa iji mee ihe mkpuchi mkpuchi, dị ka mkpuchi mkpuchi mkpuchi na ihe mkpuchi mkpuchi.
8. Nyochaa ngwaọrụ ahụ: Nyochaa ngwaọrụ ahụ iji nwalee ma paramita ngwaọrụ ahụ kwekọrọ ihe achọrọ.
9. Nyocha ụlọ ọrụ: Nyocha ụlọ ọrụ ikpeazụ iji hụ na arụ ọrụ nkịtị nke akụrụngwa.
03 Nnwale
1. Ntụle mkpuchi mkpuchi: Maka ikuku ọ bụla nke ihe ngbanwe akọrọ, a chọrọ nha nguzogide mkpuchi. Nke a nwere ike ịlele ma ihe mkpuchi ahụ ọ na-emezu ụkpụrụ achọrọ.
2. Volt -ampere njirimara nha: Volt{2}}ampere njirimara nha bụ ule ịlele mkpirisi sekit na oghere mepere emepe niile windings nke otu puku ụdị transformer. N'otu oge ahụ, ọ nwekwara ike tụọ ike ya agbagoro, mfu ibu, enweghị - ibu ọnwụ na njirimara ụkpụrụ voltaji.
3. Nnwale ike mkpuchi: Nnwale ahụ na-enyocha nguzogide voltaji nke ihe mkpuchi, ma tụọ ike mkpuchi nke ihe ngbanwe site na ule nrụgide.
4. Mgbanwe nha nha: nha nha mgbanwe mgbanwe bụ nnwale iji lelee njirimara nnyefe nke ngbanwe ụdị puku. Nke a nwere ike ịlele ma mgbanwe mgbanwe mgbanwe kwụsiri ike n'okpuru steeti ibu dị iche iche.
5. Nnwale sekit dị mkpụmkpụ: Nnwale sekit dị mkpirikpi bụ ule maka ịlele ọnwụ ihe ngbanwe akọrọ na oke okpomọkụ. Nke a na-enyere aka ịlele ma transformer na-arụ ọrụ nke ọma n'okpuru ọnọdụ sekit dị mkpirikpi.
6. Nnwale nkwụsi ike n'ọrụ: Nnwale a na-enyocha ike akọrọ{1} ụdị transformer nwere ike iguzogide nrụgide igwe. A na-atụle ọnụọgụ ngbanwe nke axial na ntụgharị nke mgbagwoju anya na ntụgharị site na itinye ike.

04 Mbukota na mbupu


05 Saịtị na nchịkọta
Daalụ maka mmasị gị na VPI dry-ụdị transformers! Ngwaahịa anyị bụ ndị ama ama maka arụmọrụ pụrụiche ha, ịdị mma a pụrụ ịdabere na ya, yana imewe enyi na enyi, raara onwe ya nye inye azịza ike dị mma na nchekwa n'ofe ụlọ ọrụ dị iche iche. Ma maka ngwa ụlọ ọrụ mmepụta ihe, ụlọ azụmahịa, ma ọ bụ ihe pụrụ iche chọrọ, VPI akọrọ{3}} ụdị ihe ngbanwe bụ nhọrọ ntụkwasị obi mgbe niile. Anyị na-atụ anya ka gị na gị na-arụkọ ọrụ iji kwalite ọdịnihu na-adigide ọnụ. Maka ozi ndị ọzọ ma ọ bụ nkwado ahaziri onwe gị, biko nweere onwe gị ịkpọtụrụ ndị otu ọkachamara anyị!

Ihe nchịkọta dị ọkụ: akọrọ ụdị nzọụkwụ ala transformer, nrụpụta, soplaya, price, efu