Obodo: South Africa 2022
Ike: 2× (3635/2562-2562) kVA
Voltaji: 22/0.462kV
Njirimara: ya na OLTC
Zipu ozi

 

 

3635 kVA transformer with rectifier

Ndozi nke ọma, ọkọnọ ọkụ a pụrụ ịdabere na ya{0}họrọ ihe nrụzigharị anyị iji nye ọdịnihu ụlọ ọrụ ike!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

3635 kVArectifier transformerE zigara South Africa na 2022. Ike a tụrụ anya nke transformer bụ 3635 kVA na OFAF jụrụ oyi. Isi voltaji bụ 22kV, nke abụọ voltaji bụ 0.267/0.462kV, ha hiwere otu vector otu Yy0y6 ma ọ bụ Dy5y11. Ihe ngbanwe bụ ngwa nrụzi nke mejupụtara ihe ngbanwe na ndị na-emegharị ihe, iji nweta ike ugbu a site na ndị na-agbanwe ike AC, nke a na-ejikarị na nnyefe ike DC, traction eletrik, igwe nchara, electroplating, electrolysis na ubi ndị ọzọ. Ụkpụrụ ahụ dị ka onye na-agbanwe agbanwe, akụkụ mbụ nke onye na-agbanwe agbanwe na-ejikọta ya na usoro ike AC, nke a na-akpọ akụkụ netwọk; A na-ejikọta akụkụ nke abụọ na rectifier, nke a na-akpọ akụkụ valve. Ụkpụrụ nhazi nke ihe ntụgharị rectifier bụ otu ihe ahụ nke onye ntụgharị nkịtị.

Ihe ntụgharị nwere rectifier na-enwekarị akụkụ abụọ bụ isi:

Akụkụ ntụgharị: A na-eji ya gbanwee voltaji nke ihe na-agbanwe agbanwe, na-atụgharịkarị elu{0}voltage alternating current ka ọ bụrụ nke dị ala{1} voltaji alternating current iji kwekọọ n'ihe achọrọ nke sekit rectifier. Emebere akụkụ a dịka mkpa nke ngwa ahụ siri dị, ọ nwekwara ike bụrụ ihe mgbaka ọkụ ma ọ bụ steepụ - ala transformer.

Akụkụ rectifier: na-enwekarị diodes, thyristors na ihe ndị ọzọ rectifier, ihe ngbanwe na-atụgharị ugbu a ka ọ bụrụ ugbu a ozugbo. Nhazi nke sekit rectifier ga-emetụta àgwà nke mmepụta DC, dị ka mgbanwe na mgbagwoju anya nke mmepụta voltaji.

 

1.2 Nkọwa nka nka

Ihe ntụgharị 3635 kVA nwere ụdị nkọwapụta na mpempe data

Enyere ya
South Africa
Afọ
2024
Ụdị
rectifier transformer
Ọkọlọtọ
IEC60076
Enyere ike
3635kVA
Ugboro ugboro
50HZ
Usoro
3
Ụdị oyi
OFAF
Voltaji nke mbụ
22 kV
Voltaji nke abụọ
0.462/0.433/0.39/0.346/0.303/0.26 kV
Ngwa ikuku
Ọla kọpa
Ntugharị akụkụ
Yy0y6/Dy5y11
Mgbochi
6.5±10%
Pịa Changer
NLTC
Na Ibu Mfu
114.4KW
Ngwa ngwa
Nhazi ọkọlọtọ

 

1.3 Eserese

3635 kVA transformer nwere eserese eserese na nha.

3635 KVA transformer with rectifier diagram 3635 KVA transformer with rectifier nameplate

 

 

02 Nrụpụta

2.1 Isi

Isi njupụta nke ihe ngbanwe na rectifier bụ otu n'ime ihe ndị bụ isi ya, nke a na-ejikarị eme ihe maka magnetik na imeziwanye arụmọrụ nke transformer. Isi laminated na-enwekarị ọtụtụ mpempe ígwè silicon ndị a kpọkọtara n'elu ibe ha, nke e ji nlezianya mee ka ọkpụrụkpụ ya na ihe onwunwe ya belata nhụsianya na nhụsianya.

N'ime usoro mmepụta ihe, a na-akwakọba akwụkwọ nchara silicon ndị a n'otu ntụziaka iji mepụta sekit magnetik mechiri emechi. Nhazi nke isi laminated nwere ike ibelata ume ume n'ụzọ dị irè ma mee ka arụmọrụ nke ihe ntụgharị ahụ dịkwuo elu.

Mpempe akwụkwọ nchara silicon nwere mfu hysteresis dị ala na ike arụ ọrụ dị elu, ma nwee ike iguzogide ọnọdụ okpomọkụ na ịma jijiji nke onye ntụgharị na-eme n'oge ọrụ. Site na usoro superposition ezi uche dị na ya, stack core nwere ike ịchịkwa ọnọdụ ọrụ nke transformer nke ọma, nye mmepụta voltaji kwụsiri ike, ma melite arụmọrụ na ntụkwasị obi nke ngwa eletriki n'ozuzu ya.

3635 KVA transformer with rectifier iron core

 

2.2 Ikuku

3635 KVA transformer with rectifier continuous winding

High voltaji na-aga n'ihu winding na-emekarị mejupụtara ọnụ ọgụgụ nke ọzọ atụgharị nke insulated wires, nke na-anọgide na-emerụ na ígwè isi. N'ihi ọtụtụ ntụgharị ya, ọ nwere ike iguzogide voltaji dị elu, ya mere ọ na-arụ ọrụ nke ịba ụba voltaji na ntụgharị rectifier. Nhazi nke ikuku ikuku a na-eburukarị n'uche ike mkpuchi na oke voltaji dị elu, na-eji ihe mkpuchi dị elu{2} iji hụ na agaghị enwe nsogbu ndakpọ ma ọ bụ ntapu mgbe arụ ọrụ. N'otu oge ahụ, nhazi na nhazi usoro nke ikuku na-aga n'ihu na-eme ka ọ nwee ndakọrịta electromagnetic ka mma ma belata nnyonye anya electromagnetic.

Igwe ikuku dị ala{{0}voltajie na-anabata usoro achịcha, nke na-enwekarị ntụgharị ole na ole ma dabara maka mmepụta ihe achọrọ nke voltaji dị ala. Nke a winding na-emekarị mejupụtara a plurality nke diski ma ọ bụ mgbanaka ụdị conductors, kewapụrụ n'ebe ibe ha site mkpuchi ihe onwunwe, n'elu. Nhazi nke winding pie nwere àgwà nkwụsị ọkụ dị mma, nke nwere ike ibelata okpomọkụ nke a na-emepụta na nnukwu ugbu a iji hụ na nkwụsi ike na nchekwa nke akụrụngwa. Tụkwasị na nke ahụ, usoro achịcha ahụ na-enyekwara aka ibelata ntanye ntanye na nkwụsịtụ, melite arụmọrụ nke ịgafe ugbu a, nke mere na onye na-agbanwe agbanwe nwere ike ịnọgide na-enwe nzaghachi dị mma mgbe ibu gbanwere.

 

2.3 tank

A na-eme tankị mmanụ ahụ nke efere igwe dị elu{0} ike gbakọtara ọnụ, na-ahụ na ike igwe yana akara siri ike iji guzogide nrụgide dị n'ime. tankị mmanụ nwere ihe nchekwa mmanụ dị n'elu, nke na-enyere aka ịhazi mgbasawanye na mbelata nke mmanụ ihe ngbanwe ma na-egbochi oke nrụgide dị n'ime. A na-etinye ala nke tank mmanụ ahụ na valvụ mmiri na-agbapụta mmanụ n'oge mmezi. N'elu nwere ike ịnwe ikuku ume ma ọ bụ gas relay iji dozie nrụgide dị n'ime na nke mpụga ma na-egbochi mmiri ịbanye.

transformer with rectifier high-strength steel oil tank

 

2.4 Mgbakọ ikpeazụ

3635 KVA transformer with rectifier assembly
3635 KVA transformer with rectifier active part

 

 

03 Nnwale

1. Ntụle nke iguzogide ikuku

2. Ntụle nke Voltage Ratio na nlele nke nchụpụ oge

3. Nyochaa mkpuchi isi na Frame

4. Nnwale voltaji etinyere

5. Nnwale voltaji butere

6. Nleta nke Mba -Ibu ibu na nke dị ugbu a

7. Nleta nke Mkpirisi -Mmetụta gburugburu na mfu ibu

 

3635 KVA transformer with rectifier test

 

04 Mbukota na mbupu

3635 KVA transformer with rectifier packing

3635 KVA transformer with rectifier shipping

 

05 Saịtị na nchịkọta

SCOTECHA na-emezi ihe nrụzigharị ihe nrụzigharị iji wepụta arụmọrụ pụrụiche, ntụkwasị obi, na arụmọrụ, ahaziri iji gboo mkpa nke ngwa ụlọ ọrụ ọgbara ọhụrụ. Site na teknụzụ dị elu, ihe owuwu siri ike, yana izi ezi na-enweghị atụ, ha na-ahụ na ngbanwe ike enweghị nkebi na ogologo ogologo- na-adịte aka. Ma ị na-eme ka nnukwu nrụpụta-, na-akwado usoro dị oke mkpa, ma ọ bụ na-anya ụzọ ngwọta ike ọhụrụ, anyị.pụrụ iche transformersnye ọkpụkpụ azụ maka ihe ịga nke ọma gị. Họrọ ngwaahịa anyị wee nweta nguzozi zuru oke nke ịdịmma, ihe ọhụrụ na ntụkwasị obi. Ọnụ, ka ike ọdịnihu!

3635 KVA transformer with rectifier supplier

 

Ihe nchịkọta dị ọkụ: transformer nwere rectifier, onye nrụpụta, soplaya, price, ọnụ