75 kVA 3 Ntugharị okporo ụzọ-13.8 / 0.22 kV|Guyana 2024
Ike: 50kVA
Voltaji: 13.8/0.22kV
Njirimara: ya na OCTC

Ọkachamara na ntụkwasị obi, Nnyenye ike dị mma- atọ{1}} opolo agbagoro{2}} nke na-agbakọnye mgbanaka, na-eme ka ike kwụsie ike maka elekere kilowatt ọ bụla-.
01 Izugbe
1.1 Ihe ndabere oru ngo
Nke 75 kVA atọ okporo osisi mounted transformer ka ebugara Guyana na 2024. Ike nke transformer bụ 75 kVA. Isi voltaji nke transformer bụ 13.8 kV na voltaji nke abụọ bụ 0.22 kV. Njikọ njikọ bụ Dyn1, na jụrụ oyi bụ ONAN. Igwe ntugharị akụkụ atọ etinyere n'osisi nke SCOTECH nwere usoro mkpuchi ezi uche dị na ya yana nguzogide mmetụta ọkụ. Nkesa na-agbanwe agbanwe n'ụdị, mfu agbakwunyere dị ala, enweghị oke ikpo ọkụ mpaghara. Obere ike electromagnetic, obere ịma jijiji na mkpọtụ. Nkesa okpomọkụ bụ otu na mmetụta jụrụ oyi dị mma. Njirimara ndọta nwere oke linearity na ọnụọgụ ọnụọgụ dị elu.
Ejiri teknụzụ dị elu mee ihe 150 kVA anyị nwere oghere ụzọ atọ nke ejiri teknụzụ dị elu wee na-enweta ihe dị elu na akụrụngwa nke na-ebute ogo a pụrụ ịdabere na ya na ogologo oge ọrụ. Anyị na-ekwe nkwa na ọ bụla transformer anyị na-ebugara agafeela ule nnabata zuru oke iji hụ na arụmọrụ kacha mma na ntụkwasị obi. Site na ntụle mbụ na nhota okwu ruo n'ichepụta, nrụnye, inye ọrụ, ọzụzụ, na mgbe nkwado ahịa gasịrị, anyị na-enye ngwọta ntụgharị ntụgharị zuru oke. Ihe ngbanwe anyị na-arụ ọrụ nke ọma n'ofe mba 50 n'ụwa niile. N'ịbụ onye kwadoro n'ịdị mma na ọrụ, anyị na-agba mbọ ka ị bụrụ onye na-ebubata mgbanwe mgbanwe ntụkwasị obi na ogologo oge - onye mmekọ azụmahịa.
1.2 Nkọwa nka nka
75 kVA atọ akụkụ okporo osisi n'ịnyịnya transformer nkọwa na data mpempe akwụkwọ
|
Enyere ya
Guyana
|
|
Afọ
2024
|
|
Ụdị
Ntugharị okporo ụzọ atọ agbagoro
|
|
Ọkọlọtọ
IEEE C57.12.00-2021
|
|
Enyere ike
75kVA
|
|
Ugboro ugboro
60HZ
|
|
Usoro
3
|
|
Agba
ANSI Grey70#
|
|
Ụdị oyi
ONAN
|
|
Voltaji nke mbụ
13.8 kV
|
|
Voltaji nke abụọ
0.22/0.127 kV
|
|
Ngwa ikuku
Aluminom
|
|
Mgbochi
2%
|
|
Ndidi
±7.5%
|
|
Ịrụ ọrụ
Karịrị ma ọ bụ nhata 98.63%
|
|
Ọkụ aka
± 2 * 2.5% @ akụkụ mbụ
|
|
Isi ihe
Mpempe akwụkwọ silicon na-adabere na ọka
|
|
Mmiri mkpuchi
PCB free Transformer Mineral Mmanụ
|
|
Enweghị mfu ibu
Ihe na-erughị ma ọ bụ haha 0.32KW
|
|
Na Ibu Mfu
Ihe na-erughị ma ọ bụ haha 0.98KW
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
1.3 Eserese
75 kVA atọ akụkụ okporo osisi n'ịnyịnya mgbanwe eserese eserese na nha.
![]() |
![]() |
02 Nrụpụta
2.1 Isi
A na-eme isi ya nke nnukwu oyi na-atụ{{1}{1}mkpụrụ silikoni a na-atụgharị, ahịrị transverse shiee ọmarịcha ụlọ, shear burr.<0.02, full oblique joint, no punching, no stacking iron wheel process; The double H adhesive makes the three columns of the core become a tight, flat and compact whole, effectively reducing the no-load loss, no-load current and noise of the transformer.

2.2 Ikuku

Igwe ihe ngbanwe na-anabata waya aluminom dị elu{{0}, nke na-ebelata mfu ahụ nke ọma, pad na ọnụnọ ya na-agba gburugburu, oghere eletrik dị otu, yana ntụkwasị obi na-abawanye. A na-eme ka nkwado ikuku dị n'ime dị ike iji meziwanye nkwụsi ike ya ma gbochie nkwụsịtụ na nrụrụ.
Ntugharị foil nwere mpempe akwụkwọ foil yiri ya, nke a na-ejikarị ọla kọpa ma ọ bụ aluminom mee ya. A na-ekewapụ foils ndị a iche ma na-agbakọta ọnụ iji mepụta nhazi nke ikuku.
Nke a imewe na-eme ka foil winding nwere ike mma okpomọkụ dissipation mgbe doro elu ugbu a, ma na-ebelata iguzogide na inductance nke winding, na mma eletriki arụmọrụ nke winding. Ihe kachasị mma nke winding foil bụ na a na-atụgharị ya na igwe ikuku pụrụ iche, nke nwere ogo dị elu nke akpaaka ma na-enye nnukwu mmepụta na àgwà ngwaahịa. Ntugharị, ya bụ, interlayer na longitudinal capacitance buru ibu, a na-ewepụ akụkụ okirikiri, mkpụmkpụ - mmegide mmetụta gburugburu dị ntakịrị siri ike, ike igwe dị elu, ihe owuwu ahụ dabara adaba, njehie axial na radial dị obere, nha geometric dị mfe iji hụ na ntụgharị ahụ siri ike, ọ dịghị mfe ịnweta afụ ọnụ. Igwe ikuku na-efe efe nwekwara ike ibelata mwepu nke akụkụ ma melite arụmọrụ mkpuchi nke ikuku.
2.3 tank
N'ihi na mbụ omenala akara Ọdịdị, karịsịa ebe mmanụ ntapu dị mfe ime, malite na ihe onwunwe njikwa akara iji hụ na nchara adịghị nchara, bump, ọkọ, hama, pụrụ iche nhazi nke mmanụ tank akara akụkụ, na mkpokọta eserese nke igbe, wepụ nkọ nkuku burrs na ịgbado ọkụ slag eme na nhazi nke igbe, na-ewusi adhesion nke agba.

2.4 Mgbakọ ikpeazụ


03 Nnwale
|
Mba. |
Nwale ihe |
Nkeji |
Nnabata Ụkpụrụ |
Ụkpụrụ ndị atụtara |
Mmechi |
|
1 |
Ntụle Nguzogide |
% |
Ọnụego enweghị oke nguzogide na-erughị ma ọ bụ haha 4% |
0.43 |
Gafe |
|
2 |
Nlele oke |
% |
Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha 0.5% |
-0.08~-0.01 |
Gafe |
|
3 |
Usoro-Nnwale mmekọrịta |
/ |
Dyn1 |
Dyn1 |
Gafe |
|
4 |
Mba-Ibu mfu na mkpali dị ugbu a |
% kW |
I0 : nye uru a tụrụ atụ P0: nye uru a tụrụ atụ nnabata maka enweghị ibu ibu bụ +0% |
1.21 0.266 |
Gafe |
|
5 |
Ibu Mfu Mgbochi Mgbochi voltaji na arụmọrụ |
% kW kW |
t:85 ogo Z%: uru tụrụ Pk: uru tụrụ Pt: uru tụrụ nnabata maka impedance bụ ± 7.5% Nkwenye maka mkpokọta mfu ibu bụ +0% Ịrụ ọrụ adịghị erughị 98.74% |
2.17 0.832 1.098 98.80 |
Gafe |
|
6 |
Nnwale voltaji etinyere |
kV |
HV /: 34kV 60s LV /: 10kV 60s |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
7 |
Nnwale Nkwụghachi Voltaji butere |
kV |
Voltaji etinyere (kV): 2 Ua Ogologo oge (s): 48 Ugboro (HZ): 150 |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
8 |
Ule ntapu |
kPa |
Ntinye nrụgide: 20kPA Ogologo oge: 12h |
Enweghị ntapu na mba Mmebi |
Gafe |
|
9 |
Ntụle Nguzogide mkpuchi |
GΩ |
HV -LV n'ala: LV-HV gaa n'ala: HV&LV ruo Ground |
53.4 50.6 48.8 |
/ |
|
10 |
Nnwale Dielectric mmanụ |
kV |
Karịrị ma ọ bụ hà nhata 45 |
52.83 |
Gafe |


04 Mbukota na mbupu


05 Saịtị na nchịkọta
Daalụ maka iwepụta oge iji mụta maka otu anyị -Phase Pole-Mounted Transformer! N'ime usoro ọkụ ọgbara ọhụrụ, ngwaahịa anyị abụghị naanị ngwaọrụ na-enye ọkụ na-arụ ọrụ nke ọma kamakwa ọ bụ isi nkuku siri ike maka ịhụ na ọrụ ike kwụsiri ike. Anyị na-agba mbọ ịnye ngwọta ahaziri maka ndị ahịa anyị, na-ejikọta teknụzụ a pụrụ ịdabere na ya na echiche enyi na gburugburu ebe obibi iji mee ka nnyefe ike dị mma. Ịhọrọ anyị pụtara ịhọrọ mmesi obi ike a pụrụ ịdabere na ya maka ọdịnihu. Anyị na-atụ anya ka gị na gị na-arụkọ ọrụ iji wuo oge ike dị mma na nke ga-adigide ọnụ!