1000 KVA Transformer 3 Oge-24 / 0.416 * 0.24 * 0.12 KV|Jamaica 2026

1000 KVA Transformer 3 Oge-24 / 0.416 * 0.24 * 0.12 KV|Jamaica 2026

Obodo: Jamaica 2026
Ike: 1000 kVA
Voltaji: 24GrdY/13.8-0.416Y/0.24*0.24DkV
Njirimara: YNyn0/YNd11
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-eweta 1000 kva transformer 3 phase-24/0.416*0.24*0.12 kv|Jamaica 2026 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

image001

Ike ebe ịchọrọ ya, ịma mma ebe ị na-ahụ ya - nke ahụ bụ ihe mgbanaka na-etinye pad.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

1000 kVA three phase pad mounted transformer e zigara USA na 2026. Ike nke transformer bụ 1000 kVA na KNAN jụrụ oyi. The elu voltaji bụ 24GrdY / 13.8 kV na ± 2 * 2.5% tapping nso (NLTC), ala voltaji bụ 0.416Y / 0.24 * 0,24D kV, ha guzobere abụọ vector otu YNyn0 / YNd11.

Abụọ dị ala-Nhazi otu Voltage Vector maka Ngbanwe voltaji

Akụkụ pụrụ iche nke ọrụ a bụ nhazi otu vector dị ala nke igwe ngbanwe, nke emere ka YNyn0/YNd11. Na njikọ YNyn0, ma elu voltaji na obere voltaji windings na-kpakpando ejikọrọ na-anọpụ iche ihe wetara, na ala voltaji n'akụkụ na-anọgide na-adọ na elu voltaji n'akụkụ. Na nhazi YNd11, a na-ejikọta ikuku voltaji dị ala na delta, na-ebute ụzọ nchịkwa 30 degrees (ma ọ bụ 330 degrees lag) n'akụkụ akụkụ voltaji dị elu. Nke a dual vector otu imewe na-enyere mgbanwe mgbanwe n'etiti dị iche iche dị ala voltaji mmepụta nhazi, na-ekwe ka ndị ahịa ime mgbanwe nke transformer nke abụọ voltaji àgwà izute iche iche usoro chọrọ. Site reconfigurable esịtidem njikọ na ojiji nke na-anọpụ iche ebe, transformer nwere ike ịnapụta bụghị naanị ọkọlọtọ 0,416 kV (akara na akara) na 0,24 kV (akara na-anọpụ iche / delta) mmepụta, kamakwa a 0,12 kV obere voltaji mgbata, na-enye nhọrọ nke atọ maka ibu pụrụ iche ma ọ bụ enyemaka ọkọnọ mkpa. Ọdịiche a emelitere na-eme ka igwe ngbanwe ndị a dabara adaba maka ọnọdụ njikọ njikọ grid dị iche iche yana ngwa voltaji dị iche iche.

Ụdị Nnwale chọrọ: DC Winding Resistance Measurement

Na agafe ule na-aga n'ihu nke akọwapụtara na protocol teknuzu, ọrụ a na-ebu ihe pụrụ iche chọrọ: a na-atụpụta nha nguzogide ikuku DC dị ka ụdị ule amanyere iwu. Nnwale a gụnyere ịgbanye DC ugbu a na-achịkwa n'ime ikuku ntụgharị ọ bụla yana tụọ ụda voltaji iji gbakọọ ụkpụrụ nguzogide. Nnwale nguzogide ikuku DC bụ ngwa nyocha dị oke egwu nke ejiri chọpụta nkwụsịtụ, njikọ adịghị mma, na sekit mepere emepe n'ime ikuku, yana iji chọpụta izi ezi nke njikọ mgbata niile. Site n'ịme ule a dị ka ụdị ule kama ịnwale ule oge niile, onye ahịa na-enweta ọkwa dị elu nke mmesi obi ike gbasara nrụgharị ikuku, ogo njikọ yana n'ozuzu nrụpụta nke ihe ngbanwe ndị a - nlebara anya dị mkpa karịsịa nyere n'ichepụta otu {{4}vector- otu na mkpa maka ịrụ ọrụ a pụrụ ịdabere na ya n'okpuru nhazi njikọ abụọ a.

 

1.2 Nkọwa nka na ụzụ

1000 kVA mpe mpe akwa akwadoro ụdị nkọwapụta na mpempe data

Enyere ya
Jamaica
Afọ
2026
Ụdị
Ihe mgbakwasa na mpe mpe akwa
Ọkọlọtọ
IEEE Std C57.12.34-2022
Enyere ike
1000 kVA
Ugboro ugboro
50HZ
Usoro
3
Nri
Loop
N'ihu
Nwụrụ anwụ
Ụdị oyi
ONAN
Voltaji nke mbụ
24GrdY/13.8kV
Voltaji nke abụọ
0.416Y/0.24*0.24 kV
Ngwa ikuku
Ọla kọpa
Otu Vector
YNyn0/YNd11
Mgbochi
5.75%
arụmọrụ
99.06%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
1.5 kW
Na Ọnwụ Ebu
14.32 kW

 

1.3 Eserese

1000 kVA mpe mpe akwa akwadoro eserese eserese na nha.

image003

image005

image007

 

 

02 Nrụpụta

2.1 Ikuku

image009

A na-eji ọla kọpa 100% electrolytic rụpụta windings transformer iji hụ na arụmọrụ dị mma, ike obere sekit dị elu, yana nkwụsi ike ọkụ ogologo oge. Isi ihe bụ imewe ụkwụ 5 nke e wuru site na ikike dị elu, akpọrepu oyi, igwe ọka silicon nchara, kpokọtara nke ọma iji belata magnetizing ugbu a na mfu efu. Nhazi ụkwụ nke 5 bara uru karịsịa maka nhazi otu vector dual (YNyn0 / YNd11), ebe ọ na-edozi nkesa nkesa n'okpuru ma njikọ kpakpando na delta, si otú ahụ na-ebelata enweghị ibu ibu na mkpali ugbu a.

 

2.2 LV ntụ ntụ ntụ (nkenke)

Akụkụ voltaji dị ala na-eji mkpara ndị na-eduzi ọla kọpa (busbars) na-ejikọ ọnụ ikuku na-ejikọta na spade ụdị LV bushings. A na-ahazi mkpara ndị a ka ha buru usoro akara ngosi zuru oke (ihe dị ka . 1 388 A na 416 V) nwere oke oke, ma emebere ya ka ọ guzogide nrụgide sekit dị mkpụmkpụ na okpomọkụ na-enweghị nrụrụ. A na-ekpuchi mkpara ndị ahụ nke ọma ma kwado ya n'ime tank ahụ iji hụ na nkwụsi ike dị ala, na-arụ ọrụ n'efu n'oge ndụ onye ntụgharị.

image011

 

2.3 Ngbanwe ngbanwe ọnọdụ abụọ

image013

Atọ FYB 10 ụdị abụọ ọnọdụ mmanụ mikpuru loadbreak switches na-arụnyere na HV ngalaba. A na-edepụta ha 10 kV, 630 A, nke nwere okpomọkụ nke 20 kA / 2s, na-eguzogide ike nke 50 kA (elu), na ndụ ọrụ nke 2000 arụmọrụ. A na-ahazi switches maka ngwa nri loop (abụọ maka loop in/out, otu maka nchekwa ihe ngbanwe), yana njikwa ọrụ nwere ike ịnweta site na akụkụ ihu.

 

2.4 H0 (HV nọpụrụ iche)

A na-ewepụta ebe na-anọpụ iche voltaji dị elu site na ahịhịa H0 raara onwe ya nye, nke bụ ụdị ANSI ụdị oghere spade abụọ nwere akara 25 kV, 208 A, nke nwere ebe dị anya nke ukwuu karịa ma ọ bụ nhata 405 mm na BIL nke 125 kV. Nke a dị iche iche H0 ọnụ na-enye ohere mgbanwe usoro grounding - na-anọpụ iche nwere ike ịbụ n'ala siri ike, impedance n'ala, ma ọ bụ hapụ n'ala mgbe ejikọrọ HV winding na wye. N'ime ọrụ delta, H0 bushing na-eje ozi dị ka ebe nnwale dị mma maka nchọpụta mkpuchi mkpuchi.
Tụkwasị na nke a, a na-enye ihe mkpuchi igwe anaghị agba nchara abụọ (otu n'ime akụkụ nke ọ bụla) maka tankị a pụrụ ịdabere na ya na nhazi usoro.

image015

 

2.5 Mgbakọ ikpeazụ

image017

Mgbakọ na-agbaso atụmatụ dị mma siri ike: nchịkọta isi, ikuku ikuku, njikọ ndu, na mkpuchi mkpuchi na-arụ ọrụ n'okpuru ọnọdụ a na-achịkwa. Akụkụ zuru oke na-arụ ọrụ na-enweta ihicha oghere na usoro ndochi mmanụ iji wepụ mmiri si na mkpuchi siri ike, na-eme ka usoro dielectric akọrọ na nke siri ike tupu njedebe ikpeazụ.

Ụgbọ mmiri ahụ bụ ụdị ihe a na-emechi emechi na mkpuchi mkpuchi, nke sitere na nchara dị nro. A na-ekpuchi ogige ahụ na Munsell 7GY3.29 / 1.5, na-ezute IEEE C57.12.28 chọrọ maka nguzogide corrosion na gburugburu osimiri. A na-enye igbe na-ebuli elu na ihe mkpuchi jacking maka njikwa dị mma.

 

 

03 Nnwale

A na-eme ule niile dabere na IEEE C57.12.34 2022 na IEEE C57.12.90.
Nlele oge niile (a na-eme na nkeji ọ bụla):
• Ntụgharị na ngbanwe nke usoro (YNyn0 na YNd11 kwadoro)
• Ọ dịghị ibu ọnwụ na-akpali akpali ugbu a
• Ibu ibu na voltaji impedance
• Igwe ọkụ etinyere (HV: 40 kV; LV: 10 kV)
• voltaji ebutere ya
• Nnwale ntapu nke tank (50 kPa maka awa 12)
• Ike dielectric mmanụ (Karịrị ma ọ bụ hà nhata 45 kV)
• DC mkpuchi mkpuchi na index polarization
Ụdị ule - ihe pụrụ iche a chọrọ maka ọrụ a bụ na a na-atụpụta nha nguzogide ikuku DC dị ka ụdị ule amanyere iwu, ọ bụghị naanị nlele oge niile. Nnwale a na-agbanye ọkụ DC na-achịkwa n'ime ikuku ọ bụla ma tụọ mgbada voltaji iji gbakọọ ụkpụrụ nguzogide. Ọ bụ nchọpụta dị oke mkpa maka ịchọpụta eriri ndị gbajiri agbaji, njikọ ntụgharị na-adịghị mma, ma ọ bụ nkwonkwo mgbata rụrụ arụ. Site n'ime ya dị ka ụdị ule, anyị na-enye ọkwa dị elu nke mmesi obi ike maka ịga n'ihu na-aga n'ihu na njikọ njikọ - nke kachasị mkpa nyere nhazi otu vector abụọ dị iche iche.

Site na mkpesa ule emechara (Serial No. 2605073), ụkpụrụ atụnyere:
• Enweghị ibu ibu: 1.1445 kW
• Ọnwụ ibu (ogo 85): 12.037 kW
• Mgbochi: 5.74%
• Ịrụ ọrụ: 99.23% - niile gafere ọnụ ọgụgụ ndị ekwenyere.

image019
image021

 

 

04 Nchegbu ndị ahịa

A gwala ọtụtụ isi ihe iji gboo mkpa ndị ahịa Canada nwere:

• Dual vector Group (YNyn0/YNd11): A na-eme njikọ dị n'ime ka e wee nwee ike ịhazigharị ikuku nke LV site na kpakpando gaa na delta. Na kpakpando, usoro na-anọpụ iche voltaji bụ 240 V na ahịrị na 416 V; na delta, ahịrị na ahịrị na-anọgide 416 V, ebe mgbata etiti n'otu oge na-enye 120 0 120 V (ya bụ, 0.12 kV) maka ibu inyeaka. Ngbanwe ahụ kwụ ọtọ, na-eji efere njikọ enyere.
• Ụdị ule achọrọ: Onye ahịa jụrụ maka iguzogide ikuku DC dị ka ụdị ule - nke a na-enye ha ihe akaebe edere nke nrụpụta nrụpụta na ịdị mma njikọ n'ofe ma nhazi ikuku.
• Ebe okpomọkụ dị n'ụsọ oké osimiri: A na-emepụta ndị na-agbanwe agbanwe site na nchebe corrosion kwalitere (sistemụ agba agba agba, ngwa igwe anaghị agba nchara) yana ọkwa BIL dị elu iji nagide ọkụ ọkụ mgbe niile, iru mmiri dị elu, na ikuku saline, dịka nkọwa Jamaica si dị (JPSCo 6950 S 04).
image023

 

 

05 Mbukota na mbupu

5.1 mbukota

A na-akwakọba ihe ngbanwe nke ọ bụla n'otu n'otu n'ime akpa osisi dị arọ, nke emebere maka njikwa ebuli ndụdụ na njem oke osimiri. A na-ejikwa ihe ndị na-adọrọ adọrọ kụchie ihe ndị nwere mmetụta (poselin, valvụ enyemaka nrụgide, nlele ọkwa). Ejiri akara "UP" na "FRAGILE" akara igbe ahụ. A na-edobe ọkwa mmanụ 100 150 mm n'okpuru tankị elu iji nye ohere maka mgbasawanye ọkụ n'oge njem.

image025

 

5.2 Mbupu

image027

A na-ebufe mbupu dị ka nkeji zuru oke (agbakọta nke ọma, mmanụ jupụtara). Tupu izipu, a chọrọ ikike ederede site n'aka onye zụrụ ya, yana a ga-edobe ma kwadokwa akụkọ nyocha akwadoro.

A na-ebufe ndị na-agbanwe agbanwe CIF Kingston, Jamaica (ma ọ bụ dị ka ọdụ ụgbọ mmiri ekwekọrịtara). Edebere ebe ebuli na nchekwa nke ọma. Nkwakọ osisi na-agbaso ụkpụrụ ISPM 15 phytosanitary maka mbupu mba ụwa. A tụlere ịma jijiji na ịma jijiji n'ụzọ na nhazi nke nkwado dị n'ime.

 

 

05 Saịtị na nchịkọta

A tụkwasara igwe ngbanwe SCOTECH n'elu maka ọrụ ime obodo, azụmahịa, ụlọ ọrụ mmepụta ihe na ume ọhụrụ. Anyị na-anabata ajụjụ gị na iwu omenala - ndị ọkachamara anyị dị njikere inyere gị aka site na nhọrọ ruo mgbe nkwado ahịa. Kpọtụrụ anyị taa - ka SCOTECH nwee ike ịga nke ọma gị.

image029

 

Ihe nchịkọta dị ọkụ: 1000 kva transformer 3 nkeji-24 / 0.416 * 0.24 * 0.12 kv|Jamaica 2026, China 1000 kva transformer 3 nkeji-24 / 0.416 * 0.24 * 0.12 kv|Jamaica 2026 ndị na-emepụta ihe, ndị na-ebu ihe, ụlọ ọrụ