2000 KVA N'ime mpempe akwụkwọ na-agbanye ihe ntụgharị-34.5 / 0.48 KV|USA 2025

2000 KVA N'ime mpempe akwụkwọ na-agbanye ihe ntụgharị-34.5 / 0.48 KV|USA 2025

Obodo: USA 2025
Ike: 2000 kVA
Voltaji: 34.5/0.48kV
Njirimara: DOE arụmọrụ
Zipu ozi

Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kacha ntụkwasị obi na ndị na-eweta 2000 kva n'ime pad mounted transformer{6}}34.5/0.48 kv|US 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

 

inside pad mounted transformer

Nyochaa, Jikwaa ma welie ya. Smart Pad{1}Anyanye ndị ngbanwe maka Grid Resilient.

 

 

01 Izugbe

1.1 Nkọwa oru ngo

2000 kVA three phase pad mounted transformer e bugara na USA na 2025. The gosiri ike nke transformer bụ 2000 kVA na KNAN jụrụ oyi. The elu voltaji bụ 34.5GrdY / 19.92 kV na ± 2 * 2.5% tapping nso (NLTC), ala voltaji bụ 0.48Y / 0.277 kV, ha guzobere vector otu YNyn0.

SCOTECH's pad mounted transformer pụtara dị ka nnukwu-arụmọrụ, ọnụ ahịa{1}ngwa dị mma maka mkpa nkesa ọkụ ọgbara ọhụrụ{2}} juru n'ọnụ na njirimara ndị kewapụrụ ya n'ahịa. N'ịnya isi 3-phase 5-limb core yana nrubeisi arụmọrụ DOE, ọ na-ebelata ihe mkpofu ume ma na-ebelata mmefu ọrụ ogologo oge{11}. Juputara na ọkụ FR3{12}} mmiri dị mma, ọ na-ebute nchekwa na nkwado ụzọ, na-adakọ na ụkpụrụ gburugburu ụwa. Ndị njide ịwa ahụ agbakwunyere na akụkụ{14}}mkpọkwasị mita na-agbakwunye uru site na ime ka nchekwa dị mfe na njikwa saịtị, ebe ihe mkpuchi ọcha RAL 9003 na-adịgide adịgide na-eme ka a mara nke ọma ọtụtụ afọ nke ọrụ a pụrụ ịdabere na ya na gburugburu mpụga. Kọmpat, dị mfe ịwụnye, ma wuo ya ka ọ dịgidere, ihe ngbanwe a bụ nhọrọ mara mma maka ndị nkesa, EPCs, na ndị nrụpụta ọrụ na-achọ ịdịmma na arụmọrụ n'otu ngwugwu.

 

 

 

1.2 Nkọwa nka nka

2000 kVA mpe mpe akwa akwadoro ụdị nkọwapụta na mpempe data

Enyere ya
USA
Afọ
2025
Ụdị
Ihe mgbakwasa na mpe mpe akwa
Ọkọlọtọ
IEEE Std C57.12.34-2022
Enyere ike
2000 kVA
Ugboro ugboro
60HZ
Usoro
3
Nri
Loop
N'ihu
Nwụrụ anwụ
Ụdị oyi
KNAN
Voltaji nke mbụ
34.5GrdY/19.92 kV
Voltaji nke abụọ
0.48Y/0.277 kV
Ngwa ikuku
Aluminom
Otu Vector
YNyn0
Mgbochi
5.75%
Ịrụ ọrụ
99.51%
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
1.95 kW
Na Ibu Mfu
13.15 kW

 

1.3 Eserese

2000 kVA mpe mpe akwa akwadoro eserese eserese na nha.

inside pad mounted transformer diagram inside pad mounted transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

inside pad mounted transformer core

Ihe atọ {{0}phase ise - isi ihe dị n'ime pad mounted transformer bụ nke nwere akwa oyi akwa -rolled silicon steel sheet, nke nwere isi ụkwụ atọ (maka winding coils atọ-phase) na akụkụ akụkụ abụọ. Akụkụ aka dị n'akụkụ na-enye ụzọ maka mgbagharị magnetik efu{5}, na-ebelata enweghị ibu ibu na mkpọtụ arụ ọrụ. Ya kọmpat imewe dabara na mpe mpe akwa arịọnụ transformer si tank ohere, awade siri ike n'ibu nkwụsi ike na-akwado windings, na ana achi achi nke ọma magnetik conduction maka ntụkwasị obi n'èzí ọrụ nkesa.

 

2.2 Ikuku

Ntugharị nke n'ime pad agbakwunyere transformer (ihe a na-agbakwụnye n'ime akwụkwọ mkpuchi mkpuchi dị n'onyinyo) nwere ihe ndị na-eduzi ọla kọpa/aluminom merụrụ n'ime akụkụ voltaji dị elu -voltaji na obere-, nke nwere kaadiboodu mkpuchi maka ikewapụ ọkụ eletrik. Ọnya n'akụkụ isi akụkụ nke isi ihe ntụgharị (a haziri n'usoro atọ), ọ na-ezute ihe mkpuchi IEEE na ụkpụrụ thermal, nwere nrụsi ike n'ọrụ iji nagide nrụgide transit/ọrụ, ma na-eme ka ntụgharị voltaji rụọ ọrụ nke ọma na nnyefe ike maka unit ahụ etinyere na pad.

inside pad mounted transformer insulting material

 

2.3 tank

inside pad mounted transformer tank

Tankị ahụ bụ corrosion - nchara nchara mkpuchi na-eguzogide ọgwụ, emebere ya iji dobe ihe ndị bụ isi (isi, windings) na mmanụ mkpuchi mgbe ọ na-enye nchebe mechiri emechi megide uzuzu na mmiri. Ngosipụta elu ya na-ebu ụzọ{{2}dobe oghere dị ka oghere maka ịwụnye HV/LV bushings, valves na ngwa ndị ọzọ, yana o nwere ihe nkwado ala maka na -saịtị - na-ezute ụkpụrụ nkesa n'èzí iji chekwaa akụkụ dị n'ime maka ịrụ ọrụ kwụsiri ike.

 

2.4 Akụkụ nọ n'ọrụ

Akụkụ nọ n'ọrụ (isi mgbakọ) nke n'ime pad mounted transformer bụ isi ihe na-arụ ọrụ ya: ọ na-ejikọta windings atọ{0} (nke a na-ekechi n'ime ihe mkpuchi), isi igwe laminated, ogwe njikọ ọla kọpa, na ụzọ ndị nwere mkpuchi, ha niile edobere na etiti nkwado igwe. Mgbakọ a na-eme ka mkpuchi ọkụ eletrik na nkwụsi ike n'ibu, na-eje ozi dị ka isi ihe maka ntụgharị voltaji, ma na-ahazi ya ka ọ dabara na tankị nke na-agbanwe agbanwe mgbe ọ na-agbaso ụkpụrụ eletrik dị mkpa.

inside pad mounted transformer active part

 

2.5 HV nọpụrụ iche (H0)

HV Neutral

A na-ebute HV Neutral (H0) nke n'ime pad a na-etinye n'ime ya site na ahịhịa H0 dị iche (ihe mkpuchi ribbed ebe a), jikọtara ya na bọs ọla kọpa. Ntọlite ​​a na-ewepụta ebe na-anọpụ iche n'akụkụ voltaji dị elu{3}, na-akwado nhazi nhazi ala na-agbanwe agbanwe (dịka ọmụmaatụ, ntọ ala ozugbo) dị ka ihe nkesa chọrọ, na-eme ka ike na-anọpụ iche na-akwalite nchekwa ọrụ nke transformer{6}ha niile dakọtara na ụkpụrụ eletrik maka nkeji n'elu pad.

 

 

03 Nnwale

Ka anyị banye miri emi n'ime Induced Voltage Iguzogide Ule{0}}Nnwale mkpuchi mkpuchi isi maka mmiri mmiri{1}}mkpudo pad nke etinyere n'ime mmiri tupu ịhapụ ụlọ ọrụ ahụ.

Ebumnuche ya bụ iji nyochaa arụmọrụ mkpuchi nke winding (gụnyere ntụgharị{{0}ka-atụgharị, oyi akwa{2} na- mkpuchi mkpuchi) yana mkpuchi isi n'etiti winding na isi/tank. Ọ na-egosipụta oke ọrụ na oke ọkụ ọkụ na-enwe mmetụta nke ngbanwe nwere ike izute n'oge ọrụ n'ezie.

N'oge ule, iji zere saturation isi, a na-etinye voltaji ọzọ nke 150Hz (ihe dịka ugboro 1.73 ugboro ugboro) na ikuku. Atụnyere njupụta voltaji ahụ ka ọ bụrụ voltaji nkeji nkeji 2 × + 1000V” n'otu ụkpụrụ, a na-edobekwa voltaji ahụ maka sekọnd 60. Maka usoro atọ - nke pad mounted transformers, voltaji ule na-abụkarị ntinye site n'akụkụ obere voltaji-; A na-ebute voltaji e lekwasịrị anya n'akụkụ elu - voltaji site na induction electromagnetic. Ka ọ dị ugbu a, a na-enyocha mgbanwe dị na ntapu nke ugbu a, oke mwepu akụkụ (chọrọ ka ọ na-erughị 10pC), yana mgbanwe na mfu dielectric winding na-enyocha ozugbo.

E nwekwara nkwado ndenye ego tupu ule na mgbe ule ahụ gasịrị: Tupu ule ahụ, voltaji mmebi (chọrọ ka ọ dị ukwuu karịa ma ọ bụ nhata 30kV) na uru ọnwụ dielectric (ihe na-erughị ma ọ bụ hà nhata 0.5%) nke mmanụ mkpuchi ahụ ga-anwale iji hụ na ntọala mkpuchi nke mmiri mmiri -mikpu gburugburu ebe obibi ruru ọkọlọtọ. Mgbe ule ahụ gasịrị, a na-anwaleghachi nguzogide mkpuchi nke winding{4}} ma ọ bụrụ na enweghị mbelata dị ukwuu na uru ahụ, a na-ekpebi na mkpuchi ahụ adịghị emebi emebi.

Induced Voltage Withstand Test
breakdown voltage

 

 

04 Mbukota na mbupu

4.1 mbukota

Nkwakọ nke n'ime pad mounted transformer nwere ọwa ígwè -gbasiri ike na isi osisi siri ike nwere akwụkwọ nyocha n'elu tray ahụ. Ngwa ahụ nwere ihe nchekwa nkuku foam/plastic/cardboard, kechie ya na ihe nkiri nchebe, wee mechie ya n'ime akpa mmiri na-ekpo ọkụ{2}} juru eju (vacuum{{3}mpumped and heat-achichiri) iji gbochie nchara. Adobere ya n'ime igbe osisi fumigated nke ejiri akara forklift na etiti-nke- ihe nledo ndọda nwere akara. Ngwa agụnyere (load switch rod, T{9}}wrench) na-echekwara na ntọala, na ROHS{10}}dabere, ihu igwe{11}}na-eguzogide multi{12}} ihe mmado ịdọ aka ná ntị asụsụ dị ka achọrọ.

packaging of pad mounted transformers

 

4.2 Mbupu

DDP

Ngwọta njem ụgbọ njem DDP anyị (Delivered Duty Payid) na-enye usoro ngbanwe zuru oke yana nchegbu{{0}n'efu maka pad gị{1}} n'elu igwe ngbanwe. Anyị na-ejikwa yinye ngwa ngwa niile- site na ibu nwere nchekwa na ibu dị n'ime ala site na mbupu oke osimiri, nwechapụ kọstọm, ọrụ mbubata na nnyefe ikpeazụ na saịtị ọrụ gị akọwapụtara. A na-akwado nke ọma nkeji ọ bụla maka mbufe site na iji mgbochi siri ike, ihe nkwado na nchedo ihu igwe. Site n'ọnụ ụzọ-na-ọnụ ụzọ yana ụgwọ na ibu ọrụ niile nke anyị na-ejikwa, ị na-enweta ọrụ turnkey nke na-eme ka ihe ngbanwe gị bịarute n'enweghị nsogbu, n'oge nhazi yana na nrube isi n'iwu obodo ebe aga.

 

 

05 Saịtị na nchịkọta

Anyị na-adịghị nnọọ rụpụta ọkọlọtọ nkeji; anyị na-emepụta ihe ngwọta dabara na mkpa pụrụ iche gị. Ma ị chọrọ nhazi voltaji omenala, ụkpụrụ nchekwa emelitere, ma ọ bụ atụmatụ ịdịte aka pụrụiche, otu anyị na-eji ọtụtụ iri afọ nke ụlọ ọrụ mara-otu esi ebupụta ngwaahịa karịrị atụmanya. N'ịkwado site na nnwale siri ike n'ọkwa ọ bụla a na-emepụta ma na-anabata ọrụ ire ere, anyị na-eguzo n'azụ transformer ọ bụla anyị na-arụ.

Mgbe ịhọrọ SCOTECH, ọ bụghị naanị na ị na-azụ ngwá ọrụ- ị na-emekọ ihe na otu ndị raara onwe ha nye idowe usoro ike gị na-aga nke ọma, ugbu a na n'ọdịnihu. Tụkwasa obi na nka anyị iji mee ka ịga nke ọma gị nwee ntụkwasị obi na-enweghị mgbagha.

after-sales service

 

Ihe nchịkọta dị ọkụ: n'ime mpe mpe akwa mounted transformer, emeputa, soplaya, price, efu