2000 KVA General Electric Pad Nkwanye Transformer-13.2 / 0.48 KV|USA 2025
Ike: 2000 kVA
Voltaji: 13.2/0.48 kV
Njirimara: DOE arụmọrụ
Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-eweta 2000 kva general pad mounted transformer{6}}13.2/0.48 kv|US 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

Ike anaghị akwụsị akwụsị, nchekwa na-enweghị nsogbu. Ihe dị iche iche mgbanwe mgbanwe{{1}Edogoro.
01 Izugbe
1.1 Nkọwa oru ngo
2000 kVA three phase pad mounted transformer e bugara na USA na 2025. The gosiri ike nke transformer bụ 2000 kVA na KNAN jụrụ oyi. The elu voltaji bụ 13.2GrdY / 7.621 kV na ± 2 * 2.5% tapping nso (NLTC), obere voltaji bụ 0.48Y / 0.277 kV, ha guzobere vector otu YNyn0.
Ezubere maka ntinye enweghị nkebi n'ime sistemu nkesa ọkụ eletrik dị n'okpuru ala, ihe mgbakwasa pad ahụ bụ ihe ngwọta dị elu- na-aga nke ọma na mgbada voltaji - na nkwụsi ike ọkọnọ ike. N'ịgbaso ụkpụrụ nchekwa ume ike DOE, a na-emezi ihe ngbanwe a maka obere-ibu na ibu ibu-, na-ebuga arụmọrụ ike dị elu nke na-atụgharị gaa na nchekwa ego buru ibu karịa ndụ ọrụ ya. N'isi nke ọrụ ya a pụrụ ịdabere na ya bụ mmanụ mkpuchi FR3 eke ester, nke na-enye conductivity thermal conductivity na ike njikwa mmiri dị mma, na-eme ka ihe ngbanwe ahụ nwee ike ijikwa ibu 20% dị elu ma e jiri ya tụnyere mmanụ ịnweta mmanụ {{8}juju nkeji ka ọ na-ejigide ọnọdụ okpomọkụ dị ala. Iji hụ na arụrụ ọrụ anaghị akwụsị akwụsị, ihe ngbanwe a nwere ihe njide arụmarụ dị elu{10} nke na-atụgharị ebili mmiri na-echekwa ihe ndị dị n'ime ya pụọ na mkpọda voltaji. Ọta static agbakwunyere na-akwalite ike dielectric, na-egbochi ndakpọ mkpuchi na ịgba mbọ hụ na nnyefe ike kwụsiri ike. Maka ịdị mfe nke nlekota na mmezi, a na-etinye igbe nlele raara onwe ya nye n'akụkụ, na-enye ohere ịnweta data arụmọrụ ngwa ngwa. Ntụ ntụ{14} Mputa nke ọcha (RAL 9003) na-eme ka ọ dịgidere ogologo oge megide ọnọdụ ihu igwe siri ike, gụnyere oke okpomọkụ na iru mmiri.
Ma na-eje ozi na ebe data, ebe ịzụ ahịa, ma ọ bụ ụlọ ọrụ mmepụta ihe, ihe ngbanwe a na-etinye n'elu na-ebuga nkesa ike na-agbanwe agbanwe, na-arụ ọrụ nke ọma na nke a pụrụ ịdabere na ya.
1.2 Nkọwa nka nka
2000 kVA mpe mpe akwa akwadoro ụdị nkọwapụta na mpempe data
|
Enyere ya
USA
|
|
Afọ
2025
|
|
Ụdị
Ihe mgbakwasa na mpe mpe akwa
|
|
Ọkọlọtọ
IEEE Std C57.12.34-2022
|
|
Enyere ike
2000 kVA
|
|
Ugboro ugboro
60HZ
|
|
Usoro
3
|
|
Nri
Loop
|
|
N'ihu
Nwụrụ anwụ
|
|
Ụdị oyi
KNAN
|
|
Voltaji nke mbụ
13.2GrdY/7.621kV
|
|
Voltaji nke abụọ
0.48Y/0.277 kV
|
|
Ngwa ikuku
Aluminom
|
|
Otu Vector
YNyn0
|
|
Mgbochi
5.75%
|
|
Ịrụ ọrụ
99.51%
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
±2*2.5%
|
|
Enweghị mfu ibu
1.95 kW
|
|
Na Ibu Mfu
13.15 kW
|
1.3 Eserese
2000 kVA mpe mpe akwa akwadoro eserese eserese na nha.
![]() |
![]() |
02 Nrụpụta
2.1 HV

HV bushing for pad mounted transformers, nke Chardon's 15-LBI200 nlereanya gosipụtara, bụ klaasị 15kV, 200A loadbreak bushing ntinye nke na-abanye na olulu mmiri ọkọlọtọ 200A. Ọ na-egosipụta ụzọ ọ bụla-ọla kọpa ugbu a, peroxide{10}} EPDM gwọchara, yana ọta na-eduzi, na-ezute IEEE Standard 386 maka ngbanwe zuru oke yana arụmọrụ a pụrụ ịdabere na ya. Ezubere maka ngbanwe mpaghara na-ewepụghị ihe ntụgharị ọkụ, ọ na-eme njikọ na-ekpuchi mkpuchi, na-akwado ngbanwe na mmechi mmechi, ma na-enye ohere nrụnye ngwaọrụ n'efu ma ọ bụ torque site na broach hex dị n'ime.
2.2 LV ọkụ
The LV bushing for pad mounted transformers, nke ihe nlereanya BFG na-anọchi anya ya bụ -1/2500, bụ resin nkụ{9}}ụdị bushes na-agbaso GB/T4109 na IEC60137. Ọ nwere voltaji na-eguzogide 10kV AC kpọrọ nkụ, voltaji ọkụ ọkụ 30kV, mwepu akụkụ na-erughị ma ọ bụ nhata 10pC na 1.2kV, obere oge okpomọkụ nke 62.5kA/2s, yana ogologo creepage Karịrị ma ọ bụ nhata 35mm. Ezubere ya maka nrụnye kwụ ọtọ, ọ nwere elu ihe na-eme ihe nwere tin-plated, na-anagide ibu cantilever nke 200N, na-arụ ọrụ na gburugburu ogo -35 ruo +40, na-abịa na mgbanaka akara akụkụ akụkụ anọ 90×70×6, ma dabara n'akụkụ oghere kabinet akọwapụtara.

2.3 Bay-O-Net fuse

Bay{0}O{{1}Net fuse for pad mounted transformers dị na 23kV ( sidewall/cover-mounted) na 38kV (sidewall-mounted) ratings, e mere maka ojiji na ngbanwe jupụtara na Envirotemp FR3 fluid, transformer mmanụ ma ọ bụ ihe akwadoro. Na-egosipụta operability hotstick, ihe owuwu nwụrụ anwụ maka nchekwa, yana akụkụ akụkụ nke nhọrọ{8}nwụnye valvụ flapper iji belata nsị mmanụ, o nwere ọla kọpa ma ọ bụ ọlaọcha{9}}plated ọnụ (ọlaọcha{10}ọkọlọtọ maka 38kV) maka njikọ a pụrụ ịdabere na ya, na-akwado ọrụ nkwụsịtụ, ma na-enye ohere nyocha ngwa ngwa na-enweghị ngwaọrụ pụrụ iche. A ghaghị iji ya mee ihe n'usoro nwere njikọ dịpụrụ adịpụ ma ọ bụ nke ugbu a{13}} na-egbochi fuse iji gbochie mmejọ dị ugbu a{14}, na-ahụ maka nchekwa maka transformers na sistemu nkesa.
2.4 Valve Mwepụta nrụgide
Emebere valvụ ntọhapụ nrụgide iji kpuchido tankị ngbanwe site na oke nrụgide dị n'ime. Ọ na-emepe ozugbo ozugbo ịhapụ gas mgbe nrụgide tank ruru ọkọlọtọ 10 psi ntọhapụ (nke a na-emezi) ma mechie ozugbo nrụgide dara na ọkwa dị mma, yana nhọrọ enyemaka nrụgide ntuziaka site na ịdọrọ hoop ya. Na-egosipụta ọkọlọtọ 1 / 4-18NPT arịọnụ ịghasa (nwere ike ịhazi), ọ na-arụ ọrụ na gburugburu 0 ~ 80 ogo okpomọkụ na<95% humidity, requires sealant for sealed installation, should be kept away from high-traffic areas to avoid harm from high-temperature released gas, and is not suitable for corrosion-prone sites damaging rubber and copper.

2.5 Thermometer ntụgharị

Emebere BWS-70 Transformer Thermometer maka pad mounted transformers iji gosi okpomọkụ mmanụ na tankị nke na-agbanwe agbanwe, na-egosipụta mmetụta dị elu, ọgụgụ doro anya, nhazi dị mfe na ntụkwasị obi dị elu. A na-eji igwe anaghị agba nchara mee ikpe ya, na-eme ka ọdịdị mara mma na ogologo ndụ ọrụ. Maka ihe ngosi okpomọkụ ziri ezi, a ghaghị ịtinye bọlbụ temometa karịa 100mm n'ime ọkara; ekwesịrị ichebe ya site na nkukota, na-ehulata na nrụrụ n'oge njem na ojiji, a gaghị eji shei nlele ahụ mee ihe dị ka spanner n'oge echichi, a na-achọkwa nlele kwa afọ n'oge ọrụ.
03 Nnwale
Nnwale a na-eme maka 2000kVA atọ - nke onwe - mmiri jụrụ oyi{3}}mkpụrụ ọkụ na-ekpudo n'ime mmiri (ụdị: 0.48Y/0.277-13.2GrdY/7.6kV) na-agbaso ụkpụrụ IEEE (dịka, C., C., 0.052). C57.12.34-2022. Nnwale niile gafere na nsonaazụ tozuru oke, na-ezute njirisi nnabata na-enweghị okwu dị ka ndakpọ voltaji ma ọ bụ ntapu.


04 Mbukota na mbupu


05 Saịtị na nchịkọta
Na SCOTECH, a na-emezi igwe mgbanaka pad anyị iji kọwapụta ntụkwasị obi, ịrụ ọrụ na nchekwa maka sistemu ike ikesa {{0}site n'ugbo anyanwụ na ebe nchekwa ike ruo grids azụmahịa na mpaghara obibi. Ewuru ya na ihe siri ike, ihu igwe-atụmatụ na-eguzogide na nkenke{3}} ngwa ndị arụrụ arụ ọrụ, ha na-arụ ọrụ na-agbanwe agbanwe ọbụlagodi na gburugburu mpụta kacha sie ike, na-ebelata oge ịla n'iyi ma na-eweda ogologo oge- ọnụ ahịa ọrụ.
Anyị ghọtara na ọrụ ọ bụla nwere mkpa ike pụrụ iche. Ọ bụ ya mere a ga-eji na-emezigharị ihe ndị a na-etinye na pad anyị ka ọ nwee ike iru voltaji, ikike na ntinye chọrọ, na-ahụ na ndakọrịta enweghị nkebi na akụrụngwa gị dị ugbu a. N'ịkwado site na afọ iri afọ nke nka nka nke SCOTECH n'ichepụta ihe ntụgharị, njikwa mma na nkwado zuru ụwa ọnụ, ị nwere ike ịtụkwasị obi na ngwaahịa anyị iji mee ka ọrụ gị nwee nkwụsi ike na-enweghị atụ. Soro SCOTECH na-emekọ ihe maka mgbanaka mgbanaka na-abụghị naanị ụkpụrụ ụlọ ọrụ{3}ha na-edobe ha. Ka anyị wulite ọdịnihu ike dị mma, na-adigide ọnụ.

Ihe nchịkọta dị ọkụ: n'ozuzu electric mpe mpe akwa arịọnụ transformer, emeputa, soplaya, price, efu
You Might Also Like
750 kVA Liquid jupụtara Transformers-12.47 / 0.6 kV|...
300 kVA Green Box Transformer-12 / 0.12 * 0.24 kV|Ja...
750 kVA Pad Nkwanye Ntugharị Ọnụ-13.8 / 0.22 kV|Guya...
2500 kVA Pad Mount Transformer-12.47 / 0.48 kV|USA 2025
1500 kVA Pad Mount Transformer-13.8 / 0.46 kV|Guyana...
1000 kVA fotovoltaic transformer-13.2 / 0.48 kV|USA ...