2660 KVA n'èzí ngbanwe igbe-22.8 / 0.8 KV|USA 2025
Ike: 2660kVA
Voltaji: 22.8/0.8 kV
Njirimara: arụmọrụ DOE nwere igwe bọs ọla kọpa
Jiangshan Scotech Electric Co., Ltd bụ otu n'ime ndị nrụpụta kachasị ntụkwasị obi na ndị na-ebunye igbe ngbanwe n'èzí 2660 kva-22.8/0.8 kv|US 2025 na China. Biko nweere onwe gị ịzụta ngwaahịa dị ọnụ ahịa maka ọrịre ebe a wee nweta eserese site na ụlọ ọrụ anyị. Kpọtụrụ anyị maka nkọwa ndị ọzọ.

Igbe ngbanwe dị n'èzí na-ebuga nchekwa, ntụkwasị obi na nke ọma- ike nkesa voltaji maka netwọọkụ ọgbara ọhụrụ na ụlọ ọrụ mmepụta ihe.
01 Izugbe
1.1 Nkọwa oru ngo
Na 2025, onye ahịa America nyere iwu maka a2660 kVA atọ nkeji mpe mpe akwa n'ịnyịnya transformer, emebere maka ntinye n'ime netwọk nkesa nkesa voltaji na United States, ebe ntụkwasị obi, nchekwa na ogologo oge- ịrụ ọrụ dị mkpa maka akụrụngwa ike ọrụ ahụ. Ihe ngbanwe ahụ na-arụ ọrụ dị ka igbe ngbanwe dị n'èzí, na-ejikọta tankị nke na-agbanwe agbanwe, akụrụngwa mgbanwe, ngwaọrụ nchebe, na ihe njikọ eletrik n'ime pad kọmpat{2} agbakwunyere ogige kwesịrị ekwesị maka netwọk nkesa ọrụ yana gburugburu ụlọ ọrụ mmepụta ihe. Na mgbakwunye, dịka akụkụ nke otu usoro ahụ, onye ahịa zụtara nke pere mpe150 kVA mpe mpe akwa n'ịnyịnya transformerinye ibu inyeaka n'ime sistemu eletriki oru ngo a.
The unit na-nyere na 2660 kVA, na a isi voltaji nke 22.8 kV na nke abụọ voltaji nke 0.8 kV, na-eji YNd1 vector otu, nke na-akwado kwụsiri ike atọ-phase voltaji mgbanwe; A na-edobe nchụpụ oge kwesịrị ekwesị na njiri ala, dịka achọrọ maka sistemu nkesa nkesa voltaji. Nhazi a na-ewedata ike ọrụ- ike voltaji nke ọma, ebe ọ na-ebuga voltaji na-agbanwe agbanwe na ibu eletrịkị na-agbadata{7}}nwere ntụkwasị obi, kwụsie ike ma dị njikere maka njikọta grid.
Ezubere ma rụpụta ya dị ka IEEE Std C57.12.34-2022 si dị, onye ngbanwe ahụ na-agbaso ụkpụrụ North America maka akụrụngwa na-ebunye ihe ngbanwe, na-eme ka ọrụ nchekwa dị na sistemụ nkesa n'okpuru ala na nrụnye n'èzí ebe a ga-eji nlezianya chịkwaa ikpughe gburugburu ebe obibi na nchekwa ọrụ.
1.2 Nkọwa nka nka
2660kVA atọ na-adọ mpe mpe akwa n'ịnyịnya transformer nkọwa na data mpempe akwụkwọ
|
Enyere ya
America
|
|
Afọ
2025
|
|
Ụdị
Atọ nke mpe mpe akwa ugwu transformer
|
|
Ọkọlọtọ
IEEE Std C57.12.34-2022
|
|
Enyere ike
2660KVA
|
|
Ugboro ugboro
60HZ
|
|
Nri
Loop
|
|
N'ihu
Nwụrụ anwụ
|
|
Usoro
atọ
|
|
Ụdị oyi
KNAN
|
|
Mmiri mkpuchi
Mmanụ FR3
|
|
Voltaji nke mbụ
22.8 kV
|
|
Voltaji nke abụọ
0,8 kV
|
|
Otu Vector
YNd1
|
|
Ngwa ikuku
Aluminom
|
|
Mgbochi
5.75%
|
|
arụmọrụ
DOE
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
±2*2.5%
|
|
Enweghị mfu ibu
2,5kV
|
|
Na Ọnwụ Ebu
16,5 kV
|
|
Ngwa ngwa
Ọta ala
|
1.3 Eserese
2660kVA atọ akụkụ mpe mpe akwa n'ịnyịnya transformer ịbịaru na nameplate
![]() |
![]() |
02 Nrụpụta
2.1 tank na ihe mkpuchi

Mpempe akwụkwọ - tankị ngbanwe a na-ekpudo bụ ihe agbakọchara nke ọma, mechiri emechi, nke a rụrụ ka ọ ga-adịte aka yana mebie-, dabara adaba maka nrụnye n'èzí. A na-echekwa ọnụ ụzọ ya na bolts penta na 3-kpọchi oghere; ihe na-acha ọcha na-ekpuchi ntụ ntụ (RAL 9003) na-enye nguzogide gburugburu ebe obibi, corrosion, na mmebi UV.
2.2 Sistemụ mkpuchi
Ihe ngbanwe ahụ na-eji mmiri mkpuchi ester eke FR3. windings nke isi na nke abụọ bụ aluminom na mkpuchi ka ọ nagide ma nkeji abụọ - ruo -phase and phase - to- stress voltaji. Na mgbakwunye, otu ahụ nwere ọta electrostatic gbanyere mkpọrọgwụ n'etiti windings nke isi na nke abụọ, nke na-ebelata nnyonye anya ugboro ugboro na oke voltaji{{7}.

03 Sistemụ nlekota na nchekwa
3.1 Nchekwa eletriki na nlekota oru

Iji hụ na ọrụ nchekwa na ntụkwasị obi na-arụ ọrụ, onye na-ekesa ihe nkesa voltaji nwere ọtụtụ ihe nleba anya na ihe nchebe agbakwunyere n'ime igbe mkpuchi n'èzí. Atụmatụ gụnyere:
• Ala electrostatic ọta
• Ọkwa mmanụ, okpomọkụ mmanụ, na ihe nrụgide tankị
• Valve enyemaka nrụgide maka nchebe oke nrụgide
• Ndị njide ịwa ahụ
• Ụgbọ ala ọla kọpa maka njikọ na fuses mpụga
• Ibunye mgbanaka nkwụsịtụ
|
Ngwaọrụ |
Ọrụ |
|
Nlele ọkwa mmanụ |
Na-enyocha ọkwa mmanụ mkpuchi |
|
Nlele okpomọkụ mmanụ |
Na-enyocha ọnọdụ okpomọkụ na-arụ ọrụ transformer |
|
Igwe nrụgide tankị |
Na-achọpụta mgbanwe nrụgide ime |
|
Valve enyemaka nrụgide |
Na-echebe megide oke nrụgide dị n'ime |
Ngwa nlekota ndị a na-enye visibiliti na-arụ ọrụ na-aga n'ihu, na-ekwe ka ndị otu na-arụzi ọrụ chọpụta nsogbu ndị nwere ike tupu ha abanye na ọdịda arụmọrụ. Nleba anya mgbochi na-eme ka ntụkwasị obi dịkwuo elu ma na-ahụ na ogologo oge{1} nkwụsi ike nke netwọọkụ nkesa voltaji. Na mgbakwunye, ndị na-arụ ọrụ nwere ike ime ngwa ngwa maka ọnọdụ adịghị mma, na-ebelata oge nkwụsị.
3.2 Ngwa mgbanwe na nchekwa
Ihe ngbanwe ahụ na-akwado nchikota ya na ndị ahịa{0}} ngwaọrụ nchebe mpụga wetara, gụnyere Eaton Bussmann High-Speed Fuse 170M series, e mere iji nye nzaghachi ngwa ngwa maka mmejọ eletrik. Ngalaba ahụ gụnyere:
• Mgbanwe nkwụsịtụ ibu ibu atọ abụọ{{0}
• Ụgbọ ala ọla kọpa maka njikọ fuse
• Ndị na-ejide ndị na-ahụ maka ọkụ ọkụ na nchebe ịwa ahụ

Nhazi a na-enye ohere ka igwe mgbanaka mgbanaka nke pad atọ nwere ike kewapụ mmejọ eletrik n'enweghị nsogbu ebe ọ na-aga n'ihu maka netwọk nkesa nke fọdụrụ. Ngbanwe na nchekwa ahaziri ahazi na-eme ka nzaghachi mmejọ ọsọ ọsọ, nchekwa sistemu a pụrụ ịdabere na ya, na nnyefe ọkụ anaghị akwụsị akwụsị, na-eme ka igbe mgbanaka dị n'èzí dabara nke ọma maka ịba uru-ọnụọgụ na ngwa PV nke anyanwụ.
04 Nnwale

Nsonaazụ ule



05 Mbukota na njem


06 Ngwa a na-ahụkarị
Dị ka igbe ngbanwe dị n'èzí, nke a na-etinye ihe ngbanwe a na-eme ka ọ bụrụ nrụnye n'ọtụtụ ebe dị iche iche nke na-ekesa voltaji, gụnyere sistemu ike ụlọ ọrụ, akụrụngwa akụrụngwa, akụrụngwa ume ọhụrụ, na netwọk nkesa azụmahịa ebe achọrọ nrụnye nrụnye n'èzí dị mma.
Ngwa a na-ahụkarị gụnyere:
• Utility ọkara-Sistemụ nkesa voltaji
• Nkesa ike ụlọ ọrụ
• akụrụngwa ume ọhụrụ, gụnyere ugbo PV anyanwụ
• Akụrụngwa na ọrụ azụmahịa
N'ebe ndị a, ihe ntụgharị na-enye ntụgharị voltaji dị mma ma na-ejigide ntụkwasị obi arụ ọrụ dị elu, na-emekwa ka njikọ dị mfe na nkeji eletrik inyeaka ihe ntụgharị.
07 Saịtị na nchịkọta

N'ime akụrụngwa eletriki zuru oke nke oru ngo ahụ, igbe ngbanwe dị n'èzí 2660 kVA na-eje ozi dị ka ihe ntụgharị nkesa ọkụ eletrik bụ isi, na-agbanwe ike ịba uru - ike voltaji ka ọ bụrụ ọkwa voltaji eji arụ ọrụ maka sistemu eletriki mgbada ebe na-eme ka arụ ọrụ nchekwa na kwụsie ike site na IEEE- ụkpụrụ dabara adaba, sistemu mkpuchi FR3, yana akụrụngwa nchekwa agbakwunyere. Onye ngbanwe ahụ na-etolite ngalaba ntụgharị ike etiti n'ime netwọk nkesa nke ọrụ ahụ, na-arụkwa ọrụ na nhazi na igbe eletriki inyeaka 150 kVA iji hụ na a pụrụ ịdabere na ọkụ na-aga n'ihu.
Ihe nchịkọta dị ọkụ: igbe ngbanwe n'èzí, onye nrụpụta, onye na-eweta, ọnụahịa, ọnụ ahịa
You Might Also Like
225 kVA Pad Mount Transformer-34.5 / 0.208 kV|USA 2024
75 kVA 3 Ngbanwe nkesa nkesa-13.8 / 0.208 kV|Canada ...
5 MVA Pad Mount Transformers-33 / 0.48 kV|USA 2025
300 KVA Pad na-ebunye ihe ngbanwe ebe obibi-12.47 * ...
250 KVA Obere mpe mpe akwa na-ebugharị ihe ntụgharị-...
1000 KVA Pad Nkwanye Ntugharị Grounding-4.16 / 0.48 ...
Zipu ozi