500 kVA Pad Nkwanye Ntugharị-13.2 / 0.48 kV|USA 2025
Ike: 500kVA
Voltaji: 13200GrdY/7620-480V
Njirimara: DOE 2016

500 kVA pad mounted transformer{1}} na-ebunye ike dị mma, dị ọcha na nke ọma yana ụkpụrụ arụmọrụ DOE 2016
01 Izugbe
1.1 Ihe ndabere oru ngo
Ihe oru ngo a gụnyere inye 500 kVA atọ -phase pad - nkwụnye nkesa nkesa, emebere maka sistemu 60 Hz na voltaji bụ isi nke 13.2 kV GrdY / 7620 V na voltaji nke abụọ nke 480 V. Ihe ntụgharị nwere atụmatụ ONAN (Oil Natural Air Natural) na-eme ka obi dị jụụ, na-arụ ọrụ nchekwa nchekwa, ma na-eme ka nhazi nri nwuru anwu. Ejiri otu vector YNd1 wuo ya ma nwee ihe mgbochi nke 5.75%.
Emepụtara ya na nrube isi n'ụkpụrụ nrụpụta ike ike DOE 2016, ihe mgbanaka 500 kva na-ebunye ihe nrụnye dị elu na mfu ume dị ala{3}}5.75 kW enweghị ibu na ọnwụ 0.65 kW n'ike.
Nke a 500 kVA 13.2 kV / 480 V atọ -phase pad - mgbakwasa transformer dị mma maka ọkara{5}}voltaji ruo ala- nkesa voltaji na obodo mepere emepe na mpaghara ime obodo. Ngwa a na-ahụkarị gụnyere:
• Obodo obibi, na-enye ike maka ọkụ ọkụ, HVAC, na ngwa ụlọ
• Ụlọ ahịa dị ka ụlọ ọrụ, nnukwu ụlọ ahịa, na ogige ndị na-ere ahịa
• Ụlọ ọrụ mmepụta ihe dị ọkụ, na-enye ike obere ruo etiti{0} akụrụngwa na igwe
• Ụlọ ọrụ dị ka ụlọ akwụkwọ na ụlọ ọgwụ chọrọ ike a pụrụ ịdabere na ya na nchekwa
• Sistemụ nkesa n'okpuru ala, ejiri na netwọk ndepụta loop maka nkwalite ntụkwasị obi na nchekwa
Mpempe akwụkwọ ya- atụkwasịkwara, loop{1} nri, yana nwụrụ anwụ{2} imewe ihu na-eme ka ọ dabara maka nrụnye n'èzí ma ọ bụ n'ala{3} ebe oghere, nchekwa na nnweta bụ isi.
1.2 Nkọwa nka nka
500kVA atọ na-adọba mpe mpe akwa n'ịnyịnya transformer nkọwa na data mpempe akwụkwọ
|
Enyere ya
America
|
|
Afọ
2025
|
|
Ụdị
Atọ nke mpe mpe akwa ugwu transformer
|
|
Ọkọlọtọ
IEEE Std C57.12.34-2022
|
|
Enyere ike
500KVA
|
|
Ugboro ugboro
60HZ
|
|
Nri
Loop
|
|
N'ihu
Nwụrụ anwụ
|
|
Usoro
Atọ
|
|
Ụdị oyi
ONAN
|
|
Voltaji nke mbụ
13.2 kV
|
|
Voltaji nke abụọ
0,48 kV
|
|
Otu Vector
YNd1
|
|
Ngwa ikuku
Aluminom
|
|
Mgbochi
5.75%
|
|
Ịrụ ọrụ na ọnwụ
DOE 2016
|
|
Pịa Changer
NLTC
|
|
Ọkụ aka
±2*2.5%
|
|
Enweghị mfu ibu
5.75 W
|
|
Na Ọnwụ Ebu
0.65 W
|
|
Ngwa ngwa
Nhazi ọkọlọtọ
|
1.3 Eserese
500 kva mpe mpe akwa agbakwunyere nkọwapụta ntụgharị na mpempe data
![]() |
![]() |
02 Nrụpụta
2.1 Isi
Nhazi isi ụkwụ ise - na-eme ka ụzọ mgbagharị magnetik kwụ ọtọ maka usoro atọ niile. Ọbụna n'okpuru efu -usoro mmiri - dị ka nke otu -ahịrị - na -mmejọ ala{7}}ma ọ bụ n'oge ọnọdụ nbudata na-ezighi ezi, magnetik flux nwere ike na-aga nke ọma site na ụkwụ mpụta abụọ. Nke a na-ebelata enweghị mmasị magnetik, na-ebelata ịrị elu okpomọkụ, ma na-ebelata ịma jijiji.
Nhazi isi a bara uru nke ukwuu maka ndị na-agbanwe ihe nke YNd vector, n'ihi na ọ na-enye ụzọ doro anya maka mgbanwe efu-usoro mgbe kpakpando - jikọtara elu dị elu{2}} voltaji n'akụkụ na-anọpụ iche gbadoro ụkwụ, wee na-eme ka nkwụsi ike eletrik na ntụkwasị obi sistemụ.
2.2 Ikuku

Igwe ikuku {{0}voltaji dị elu na-eji njikọ kpakpando (Y) nwere ọnụ ọgụgụ dị elu nke ntụgharị iji hụ na nkesa voltaji otu yana ezigbo mkpuchi mkpuchi. A na-ejikọta ikuku ikuku dị ala {{2}voltaji na nhazi delta (D), emebere ya maka ntụgharị dị ugbu a dị elu yana nke pere mpe, na-ejikarị usoro ikuku ikuku na-arụ ọrụ maka ike igwe na-ebuwanye ibu na ikike ibu ugbu a-.
A na-ejikarị otu vector YNd1 eme ihe na sistemu ike North America na-achọ oke ike{1}} na obere{2} voltaji, mbelata nkwekọ, na ike ịkụda ala.
2.3 tank
Nke a 500 kva pad mounted transformer na-egosipụta tank mmanụ dị nro dị nro nwere mkpuchi mkpuchi, na-enye nguzosi ike n'ezi ihe na nguzogide corrosion. Ọ na-agafe ule ntapu nrụgide kwa IEC 60076-1 iji hụ na arụrụ ọrụ mmanụ adịghị.
A na-ekwanye otu radiators corrugated n'azụ, akara{0}} welded na tank ahụ iji mee ka ikuku dị jụụ ka ọ na-ejigide mmiri ozuzo{1}}free ọrụ. Nhazi kọmpat a na-akwado arụmọrụ ọkụ kwụsiri ike yana ogologo oge{3}} ntụkwasị obi na ngwa ike dị ọcha.

2.4 Mgbakọ ikpeazụ

N'oge mgbakọ ikpeazụ, a na-etinye ihe ndị bụ isi iji hụ na arụrụ ọrụ nchekwa 500 kVA - rịgoro n'elu.
Akụkụ voltaji {{0} dị elu gụnyere oke ohia 200A nwere ike kewapụrụ yana oke ohia na-anọpụ iche H0 maka ịkụ ala. Akụkụ dị ala{4}}voltaji nwere resin abụọ{5}cast spade{6}ụdị bushes nwere oghere isii- maka njikọ eriri echekwabara.
Ngwa nchekwa gụnyere fiusi bayonet atọ na fuses atọ dị ugbu a (CLF) maka ikewapụ mmejọ, yana ndị na-ejide mmadụ atọ bụ isi iji kpachara anya megide mmemme oke ọkụ.
A na-enye paịlị mgbada nwere otu - oghere n'akụkụ abụọ HV na LV iji kwado ịkwatu saịtị dị mma. Awụnyere ngwa niile nke ọma iji zute ụkpụrụ ịba uru na arụmọrụ.
03 Nnwale

Nnwale oge na ụkpụrụ nnwale
1. Ntụle Nguzogide mkpuchi: IEEE C57.12.90-2021 Nkeji edemede 10.11
2. Nnwale oke: IEEE C57.12.90-2021 Nkeji edemede 7; IEEE C57.12.00-2021 Nkeji edemede 9.1
3. Nnwale Mmekọrịta Oge: IEEE C57.12.90-2021 Nkeji 6
4. Ntụle Nguzogide: IEEE C57.12.90-2021 Nkeji 5
5. Ọ dịghị ibu efu na ọ dịghị ibu dị ugbu a: IEEE C57.12.90-2021 Nkeji 8, IEEE C57.12.00-2021 Nkeji 9.3
6. Nnwale nkwụghachi voltaji na-ebute: IEEE C57.12.90-2021 Nkeji edemede 10.7
7. Ngwunye ibu, Voltaji impedance na arụmọrụ: IEEE C57.12.90-2021 Nkeji edemede 9; IEEE C57.12.00-2021 Nkeji edemede 9.2
8. Nnwale voltaji etinyere: IEEE C57.12.90-2021 Nkeji edemede 10.6
9. Nnwale ntapu site na nrụgide maka mmiri mmiri{1}}Mgbanwe imikpu: IEC60076-1
Nsonaazụ ule
|
Mba. |
Nwale ihe |
Nkeji |
Ụkpụrụ nnabata |
Ụkpụrụ ndị atụtara |
Mmechi |
|
1 |
Ntụle Nguzogide |
% |
Ọnụego enweghị nguzozi kacha nguzogide |
2.29 |
Gafe |
|
2 |
Nlele oke |
% |
Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha 0.5% Akara njikọ: YNd1 |
-0.05% ~ -0.03% |
Gafe |
|
3 |
Usoro{0}}Nnwale mmekọrịta |
/ |
YNd1 |
YNd1 |
Gafe |
|
4 |
Ọ dịghị - ibu mfu na mkpali ugbu a |
/ |
I0 :: nye uru a tụrụ atụ |
0.27% |
Gafe |
|
P0: nye uru a tụrụ atụ (t:20 degrees) |
0.577kW |
||||
|
nnabata maka enweghị ibu ibu bụ +10% |
/ |
||||
|
5 |
Ibu na-efunahụ voltaji impedance na arụmọrụ |
/ |
t:85 ogo nnabata maka impedance bụ ± 7.5% Nkwenye maka mkpokọta mfu ibu bụ +6% |
/ |
Gafe |
|
Z%: uru tụrụ |
5.67% |
||||
|
Pk: uru tụrụ |
4.032 kW |
||||
|
Pt: uru tụrụ |
4.609kW |
||||
|
Ịrụ ọrụ adịghị erughị 99.35% |
99.41% |
||||
|
6 |
Nnwale voltaji etinyere |
kV |
HV: 34kV 60s LV: 10kV 60s |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
7 |
Nnwale Nkwụghachi Voltaji butere |
kV |
Voltaji etinyere (KV):2Ur |
Enweghị ọdịda nke voltaji ule a na-eme |
Gafe |
|
Ogologo oge (s):48 |
|||||
|
Ugboro (HZ): 150 |
|||||
|
8 |
Ule ntapu |
kPa |
Ntinye nrụgide: 20kPA |
Enweghị ntapu na mba Mmebi |
Gafe |
|
Ogologo oge: 12h |
|||||
|
9 |
Ntụle Nguzogide mkpuchi |
GΩ |
HV -LV n'ala: |
21.5 |
/ |
|
LV-HV gaa n'ala: |
51.6 |
||||
|
HV&LV ruo Ground |
21.2 |
04 Mbukota na mbupu
4.1 mbukota

4.2 Mbupu
Tupu ibunye, tụọ nha na ịdị arọ nke transformer, wee hazie ụzọ ga-ezere mgbochi ịdị elu, obosara na ịdị arọ. Jiri obere -akwa ma ọ bụ gwongworo pụrụiche nwere ikike zuru oke.
Kwado etiti nke ike ndọda nke transformer na ụgbọ ala. Jiri nchara ọwa na ụzọ nkwụnye kwesịrị ekwesị iji dobe isi na gwongworo ahụ, ma ọ bụrụ na enyere ya ikike. Chekwaa ihe ngbanwe ahụ na èbè ma ọ bụ agbụ site na oghere ụgbọ njem ahapụtara, na-ezere ihe ndị na-emebi emebi dị ka radiators na bushes. Kpochie ihe ndị dị n'ime ma mechie ọnụ ụzọ niile.
Debe ọsọ na-erughị ma ọ bụ ha nhata 60 km / h wee tilt Ihe na-erughị ma ọ bụ ha nhata ogo 15 n'oge njem. Zere mmegharị mberede na ịma jijiji siri ike. Kenye ndị njem ka ịlele njide na kwụsị njem n'oge ihu igwe siri ike.
Mgbe ị na-ebuli elu, debe akụkụ eriri na-erughị ogo 60 ma ọ bụ ha nhata. Jiri ogwe mgbasa ozi ma ọ dị mkpa. Na-ebuli elu mgbe niile, na maka nkeji na-enweghị elu, jiri mkpanaka ebuli elu ala.
05 Saịtị na nchịkọta
Nke a 500 kVA, 13.2 kV / 480 V atọ -phase pad - nkwụnye nkesa nkesa nwere a YNd1 vector otu, na-enye ọmarịcha ọkara -na-kewapụ voltaji dị ala na grounding ike ahaziri maka North America ike sistemụ. Nhazi isi isi ụkwụ ya ise na-ebelata efu{10}}usoro ngbanwe, na-eme ka nkwụsi ike ọrụ na ibelata ịma jijiji.
Ejiri tankị mmanụ dị nro mechiri emechi yana azụ{0}}raịdite arụnyere n'azụ, ọ na-enye nju oyi nke ọma (ONAN) yana ogologo oge- ntụkwasị obi. Ihe nwuru anwu{3}} n'ihu na-eme ka nleba anya dị mma ma dị mma. Akụkụ voltaji {{5} dị elu na-agụnye bushes dị iche iche 200A nwere ike ịkewapụta yana ahịhịa na-anọpụ iche H0 raara onwe ya nye, ebe obere - akụkụ voltaji na-eji resin{9}}cast spade{10}}ụdị bushings maka njikọ eriri echekwabara. Ngwa nchekwa dị ka fuses bayoneti, fuses dị ugbu a (CLF), na ndị na-ejide ịwa ahụ na-enye ikewapụ mmejọ a pụrụ ịdabere na ya na nchebe oke ọkụ.
Ngwa a na-ahụkarị gụnyere nkesa obere ọkụ {{0}ka- n'ime obodo mepere emepe na gburugburu ime obodo dịka obodo obibi, ogige azụmahịa, ụlọ ọrụ ọkụ, ụlọ akwụkwọ na ụlọ ọgwụ, ebe nchekwa na ntụkwasị obi dị oke mkpa. Ọ dịkwa mma -dabara maka loop n'okpuru ala{4}}sistemụ nkesa nri iji kwalite ntụkwasị obi ọkọnọ.

Ihe nchịkọta dị ọkụ: 500 kva mpe mpe akwa n'ịnyịnya transformer, onye nrụpụta, soplaya, ọnụahịa, ọnụ ahịa
You Might Also Like
2500 kVA Mpempe akwụkwọ Atọ nke Atọ{1} agbakwunyere ...
1500 kVA Pad Nkwanye Ntugharị-34.5 / 0.48 kV|US 2024
750 kVA Pad Nkwanye Ntugharị Ọnụ-13.8 / 0.22 kV|Guya...
3000 kVA Igbe ngbanwe ebe obibi-23.9 / 11.95 * 13.8 ...
1500 kVA Pad na-ebunye ihe ntụgharị ọnụahịa-23.9 / 0...
1000 kVA Nwụrụ Anwụ n'ihu Transformer-24 / 0.48 kV|U...
Zipu ozi