2000 kVA Pad Nkwanye nkesa nkesa-4.16 / 0.08 kV|USA 2024

2000 kVA Pad Nkwanye nkesa nkesa-4.16 / 0.08 kV|USA 2024

Obodo nzipu: USA 2024
Ike: 2000kVA
Voltaji: 4160-80GrdY/277 V
Njirimara: 600A integral bushings
Zipu ozi

 

 

2000 kVA pad mounted distribution transformer

Ike a pụrụ ịdabere na ya, Nhazi kọmpat - Mpempe akwụkwọ ntụkwasị obi gị tụkwasịrị obi{1}}Ngbanwe nkesa atụkwasịrị

 

 

01 Izugbe

1.1 Nkọwa oru ngo

Ebutere ya na USA na 2024, 2000 kVA atọ -phase pad- nkesa ihe nkesa ka arụnyere iji kwado IEEE Std C57.12.34-2022 wee kwekọọ n'ụkpụrụ nrụpụta ike ike DOE 2016. Ihe ngbanwe ahụ nwere isi 4.16 kV yana 480GrdY/277 V nke nwere otu vector Dyn1. Ọ na-eji windings ọla kọpa maka ịrụ ọrụ a pụrụ ịdabere na ya na ịdịte aka, KNAN jụrụ maka ịgbasa ọkụ dị mma, yana mmiri ester FR3 eke maka nchekwa ọkụ ka mma na nkwado gburugburu ebe obibi.

Nhazi ahụ nwere sistemu ndepụta loop ma nwụọ- ohere ihu, na-akwado ma ọrụ nchekwa yana mgbanwe nrụnye. Ọ gụnyekwara ihe ngbanwe enweghị- nwere oke nhazi voltaji ±2 × 2.5%. Site na ihe mgbochi nke 5.75%, enweghị- ibu efu nke 1.350 kW, yana mfu nke 16.000 kW, ihe ngbanwe a na-ebuga ngbanwe ike dị mma ma kwụsie ike maka sistemu nkesa voltaji{10}.

Ezubere iji gboo ihe achọrọ nke ụlọ ọrụ na ntọala ụlọ ọrụ nke oge a, pad anyị{0} mounted nkesa transformers na-enye kọmpat, obere{1}profaịlụ na-emebighị na nchekwa ma ọ bụ ogologo oge-.

 

 

 

1.2 Nkọwa nka nka

2000kVA atọ na-adọ mpe mpe akwa ndokwasa transformer nkọwa na data mpempe akwụkwọ

Enyere ya
USA
Afọ
2024
Ụdị
Atọ nke mpe mpe akwa ugwu transformer
Ọkọlọtọ
IEEE Std C57.12.34-2022
Enyere ike
2000 kVA
Ugboro ugboro
60HZ
Nri
Loop
N'ihu
Nwụrụ anwụ
Usoro
Atọ
Ụdị oyi
KNAN
Ihe mgbochi mmiri
Mmanụ FR3
Voltaji nke mbụ
4.16 kV
Voltaji nke abụọ
0,48 kV
Otu Vector
Dyn1
Ngwa ikuku
Ọla kọpa
Mgbochi
5.75%
Standardkpụrụ arụmọrụ na mfu
DOE 2016
Pịa Changer
NLTC
Ọkụ aka
±2*2.5%
Enweghị mfu ibu
1.350 kW
Na Ọnwụ Ebu
16,000 kW
Ngwa ngwa
Nhazi ọkọlọtọ

 

 

1.3 Eserese

2000kVA atọ na-adọ mpe mpe akwa ndokwasa transformer akụkụ na arọ nkọwa

2000 kVA pad mounted distribution transformer drawing 2000 kVA pad mounted distribution transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

Dịka ụzọ ndọta dị oke egwu, isi ihe ntụgharị na-ebufe mgbanwe n'etiti windings nke mbụ na nke abụọ. SCOTECH cores na-eji silicon steel laminations nwere ọmarịcha permeability, na-enyere mfu dị ala n'okpuru njupụta dị elu. Ihe ndị ahọpụtara nke ọma na-eme ka nzaghachi ndọta kwụsie ike yana ogologo oge- n'ofe ibu dị iche iche.

2000 kVA pad mounted distribution transformer core

 

2.2 Ikuku

Ezubere maka netwọk 4.16 kV, ihe ngbanwe a 2000 kVA Dyn1 na-eji windings ọla kọpa. Igwe mkpuchi HV na-ejiri akwụkwọ-waya kpuchie ọtụtụ-okpukpu helical maka mkpuchi dị elu. Igwe ikuku nke LV na-eme ka ike arụ ọrụ, mgbasa ọkụ, na ntụkwasị obi sistemụ n'okpuru ibu na-aga n'ihu.

 

2.3 tank

2000 kVA pad mounted distribution transformer oil tank

A na-emechi tankị nke ngbanwe na hermetically iji gbochie ikuku na mmiri, na-echebe mmanụ na-ekpuchi ya site na oxidation na mmetọ. Nke a na-eme ka ndụ mmanụ dịkwuo mma, na-edobe ike dielectric, ma na-ahụ na ogologo oge{1}} nkwụsi ike nke ihe ndị dị n'ime.

 

2.4 600AT-Mkpịsị aka ya na njide elbow

600A integral bushing dabara 4.16kV usoro na ~ 277A ibu. Ọ na-ewepụta arụmọrụ kwụsiri ike yana mkpuchi mkpuchi na nrụpụta ntụkwasị obi maka iji ogologo oge-. Ejikọrọ site na T{6}} ụdị njikọ eriri, otu akụkụ na-ejikọta na eriri ọkụ ebe nke ọzọ na-ejikọta na ikiaka-ụdị ịwa ahụ njide, na-enye oke ọkụ na nchekwa ọkụ.

600A T-Connector with Elbow Arrester

 

2.5 Mgbakọ ikpeazụ

2000 kVA pad mounted distribution transformer assembly

A na-achịkọta isi na windings, kwadoro ma chekwaa ya na nkwado mkpuchi kwesịrị ekwesị. A na-ahazi waya ndị ndu ma jikọta ya na bushes maka ịgbado ọkụ ma emechaa. A na-akwado tankị a kpochara maka mgbakọ. A na-ebuli akụkụ ahụ na-arụ ọrụ n'ime tank ahụ, na-edozi ya nke ọma, a na-echekwa ala ala, na-edozi nkwado nke ala iji hụ na nkwụsi ike na mkpuchi.

 

03 Nnwale

Nnwale oge na ụkpụrụ nnwale

1. Ntụle Nguzogide dịka IEEE C57.12.90-2021 Nkeji edemede 5 siri dị.

2. Usoro{1}}Nnwale mmekọrịta dịka IEEE C57.12.90-2021 Nkeji edemede 6 siri dị.

3. Nnwale oke dịka IEEE C57.12.90-2021 Nkeji edemede 7 siri dị.

4. Enweghị mfu ibu na enweghị ibu dị ugbu a dịka IEEE C57.12.90-2021 Nkeji edemede 8

5. Ntufu ibu, Voltaji impedance na arụmọrụ dị ka IEEE C57.12.90-2021 Nkeji edemede 9 si dị.

6. Nnwale Nkwụghachi voltaji dị ka IEEE C57.12.90-2021 Nkeji edemede 10.5.1 siri dị.

7. Nnwale voltaji etinyere dịka IEEE C57.12.90-2021 Nkeji edemede 10.6 siri dị.

8. Nnwale ntanye na nrụgide maka ndị na-eme mgbanwe mmiri mmiri - a ga-eme ule ntapu na 15 kPa maka awa 12 na-enweghị ntapu. Enweghị nrụrụ na-adịgide adịgide.

9. Ntụle Nguzogide mkpuchi

10. Oil Dielectric Test

 

2000 kVA pad mounted distribution transformer testing
2000 kVA pad mounted distribution transformer fat

 

Nsonaazụ ule

Mba.

Nwale ihe

Nkeji

Ụkpụrụ nnabata

Ụkpụrụ ndị atụtara

Mmechi

1

Ntụle Nguzogide

%

Ọnụego enweghị nguzozi kacha nguzogide

0.453

Gafe

2

Nlele oke

%

Ngbanwe nke oke voltaji na ọpịpị bụ isi: Ihe na-erughị ma ọ bụ haha ​​0.5%

Akara njikọ: Dyn1

0.05%-0.10%

Gafe

3

nkeji -nnwale mmekọ

/

Dyn1

Dyn1

Gafe

4

Ọ dịghị - ibu mfu na mkpali ugbu a

%

kW

I0 :: nye uru a tụrụ atụ

P0: nye uru a tụrụ atụ

nnabata maka enweghị ibu ibu bụ +0%

0.10%

1.390

Gafe

5

Ibu na-efunahụ voltaji impedance na arụmọrụ

%

kW

kW

t:85 ogo

Z%: uru tụrụ

Pk: uru tụrụ

Pt: uru tụrụ

nnabata maka impedance bụ ± 7.5%

Nkwenye maka mkpokọta mfu ibu bụ +0%

Ịrụ ọrụ adịghị erughị 99.51%

5.62%

15.032

16.422

99.52%

Gafe

6

Nnwale voltaji etinyere

kV

HV: 40kV 60s

LV: 10kV 60s

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

7

Nnwale Nkwụghachi Voltaji butere

kV

Voltaji etinyere (KV):

0.960

Ogologo oge (s):40

Ugboro (HZ): 180

Enweghị ọdịda nke voltaji ule a na-eme

Gafe

8

Ule ntapu

kPa

Ntinye nrụgide: 50kPA

Ogologo oge: 12h

Enweghị ntapu na mba

Mmebi

Gafe

9

Ntụle Nguzogide mkpuchi

HV -LV n'ala:

LV-HV gaa n'ala:

HV&LV n'ala:

2.66

3.25

3.72

/

10

Nnwale Dielectric mmanụ

kV

Karịrị ma ọ bụ ha nhata 40

53.6

Gafe

 

 

04 Mbukota na mbupu

2000 kVA pad mounted distribution transformer packing
2000 kVA pad mounted distribution transformer shipping

05 Saịtị na nchịkọta

2000 kVA nke Scotech's 2000 kVA three{1}phase pad mounted transformer bụ nke ejiri nlezianya rụọ ọrụ nka yana nleba anya nke ọma iji hụ na ngbanwe a pụrụ ịdabere na ya, ịrụ ọrụ nke ọma na nchekwa maka sistemu voltaji-. Emepụtara ya na nkenke{4}}cores kpokọtara, foil{5}ọnya LV, na akwụkwọ{6}}ọla kọpa HV windings, ọ na-eme ka mkpọtụ dị ala, mkpuchi siri ike, yana ogologo oge-. Tankị igwe siri ike na-echebe ihe ndị dị n'ime ya pụọ ​​​​na mkpaja na ịma jijiji, ebe agbakwunyere Bay{9}O{10}Net fuses na IEEE 386 na-akwado MOV elbow surge arresters na-enye nchebe sistemu emelitere.

Ezubere iji zute IEEE Std C57.12.34{2}}2022 na DOE 2016 ụkpụrụ arụmọrụ, ihe nkesa nkesa pad a na-enye kọmpat, obere-profaịlụ ngwọta dị mma maka ịba uru yana iji ụlọ ọrụ mmepụta ihe. Na Scotech, anyị na-agba mbọ na-ebuga ihe nkesa nkesa kacha mma - nke na-ebute nchekwa, arụmọrụ na nkwado gburugburu ebe obibi - na-eji obi ike na-arụ ọrụ gị.

2000kVA 416kV6  pad mounted distribution transformer

 

Ihe nchịkọta dị ọkụ: mpe mpe akwa arịọnụ nkesa nkesa, onye nrụpụta, soplaya, ọnụahịa, ọnụ ahịa