2000 kVA Ike nkesa ntụgharị-20 / 0.4 kV|Albania 2024

2000 kVA Ike nkesa ntụgharị-20 / 0.4 kV|Albania 2024

Obodo: Albania 2024
Ike: 2000kVA
Voltaji: 20/0.4kV
Njirimara: ya na buchholz relay
Zipu ozi

 

 

power distribution transformer

Àkwà mmiri nke nnyefe ike, ọkpụkpụ azụ nke ume {{0}transformers na-eme ka ọkụ eletrik na-aga n'enweghị nsogbu!

 

01 Izugbe

1.1 Ihe ndabere oru ngo

2 MVAnkesa nkesae zigara Albania na 2024. The gosiri ike nke ike nkesa transformer bụ 2000 kVA na ONAN jụrụ, isi voltaji bụ 20 kV na ± 2 * 2.5% tapping range @ HV n'akụkụ (NLTC), nke abụọ voltaji bụ 0.4 kV, ha guzobere vector otu Dyn5.Ihe ngbanwe nkesa mmanụ - mikpurunwere njiri mara nke ịchekwa ume na nchekwa gburugburu ebe obibi, obere mfu, obere mkpọtụ, oke ibu, ike igwe dị elu, obere mkpirisi okirikiri, obere mwepu akụkụ, ezigbo nkwụsi ike ọkụ, ntụkwasị obi dị elu, ogologo ndụ ọrụ na ihe ndị ọzọ. Nchekwa, enweghị ọkụ, mmetọ - n'efu, enwere ike rụọ ọrụ ozugbo na ebe a na-ebu ibu, enwere ike iji ya mee ihe na ụlọ ọrụ, ọrụ ugbo, ụgbọ njem, obodo mepere emepe na mpaghara ndị ọzọ, ebe maka ọdụ ọkụ ọkụ ọhụrụ, ebe data, ọdụ ọdụ 5G, kpo oku na mpaghara ndị ọzọ nwere ike chekwaa ike nke ọma wee belata oriri na ikuku. Site na ampere ezi uche dị na ya{5} na-atụgharị mgbako ike itule, ọgwụgwọ densification iji guzogide ifufe, nkesa otu na mkpirisi, nchedo ike pụrụ iche. Na mgbakwunye, flange akara na-anabata usoro uzo, valvụ mwepu mmanụ na-anabata valvụ ọla kọpa, na radiator na-anabata valvụ nru ububa oghere iji hụ na arụ ọrụ akara.

 

 

1.2 Nkọwa nka nka

2000 kVA ike nkesa transformer ụdị na mpempe akwụkwọ data

Enyere ya
Albania
Afọ
2024
Ụdị
Ihe ngbanwe ike
Ọkọlọtọ
IEC60076
Enyere ike
2000kVA
Ugboro ugboro
50HZ
Usoro
3
Ụdị oyi
ONAN
Voltaji nke mbụ
20kV
Voltaji nke abụọ
0,4 kV
Ngwa ikuku
Ọla kọpa
Ntugharị akụkụ
Dyn5
Mgbochi
6%
Pịa Changer
NLTC
Ọkụ aka
± 2 * 2.5% @ akụkụ HV
Enweghị mfu ibu
1.95 kW
Na Ibu Mfu
19.14 kW
Ngwa ngwa
Nhazi ọkọlọtọ

 

1.3 Eserese

2000 kVA ike nkesa transformer eserese na nha.

power distribution transformer drawing power distribution transformer nameplate

 

 

02 Nrụpụta

2.1 Isi

Ihe bụ isi bụ nke nnukwu permeability na obere mfu silicon ígwè mpempe akwụkwọ nwere ọmarịcha arụmọrụ, na-ebelata ọ dịghị - ibu ọnwụ na mkpọtụ. Iron isi na-anabata ọtụtụ{2}ọkwa niile-oblique nkwonkwo Ọdịdị, nke mere na ike ndọta na nkwonkwo nke ígwè core ka mma, na enweghị- ibu ọnwụ na mkpọtụ na-ebelata. Igwe mmiri na-eji ụdị waya dabara adaba, dị ka akwụkwọ-waya kpuchiri ma ọ bụ nkeonwe{7}} waya transposition nrapado na-ebelata nke ọma ibu ibu. Ọ nwere ike belata ụgwọ ọrụ nke grid ọkụ na ndị ọrụ nke ọma.

power distribution transformer steel core

 

2.2 Ikuku

power distribution transformer electrical coils

Igwe ikuku na-anabata usoro elliptik. A na-eji foil kechie eriri obere - voltaji ma were ihe mkpuchi dị elu{2}}A-E klaasị; A na-eji waya ọla kọpa merụọ eriri igwe voltaji dị elu iji melite nguzogide àmụmà. A na-ekesa axial ampere - na-atụgharị magnetik nke eriri igwe, nke nwere ike ibelata ike igwe ma melite ikike sekit dị mkpirikpi nke eriri igwe.

 

2.3 tank

A na-efesa elu nke ngwaahịa ahụ na agba mgbe e wepụsịrị mmanụ, ịcha mma na ọgwụgwọ sandblasting, nke nwere ezigbo mmiri na-eguzogide mmiri ma nwee ike izute ihe pụrụ iche nke metallurgical na petrochemical na mpaghara mmiri na unyi. Kwesịrị ekwesị maka ịrụ ọrụ na oke iru mmiri na ebe ndị ọzọ siri ike. Ahụ na tank mmanụ nwere usoro nhazi siri ike, nke mere na ọ dịghị mfe ịkwaga n'oge njem. Ngwaahịa ahụ nwere ike kwụsie ike mgbe niile n'ime ogologo oge-.

power distribution transformer tank

 

2.4 Mgbakọ ikpeazụ

power distribution transformer assembly
power distribution transformer active part

 

 

03 Nnwale

1. Ntụle nke Voltage Ratio na Lelee nke Ntugharị Oge

2. Nleta nke iguzogide ikuku

3. Nleta nke DC mkpuchi mkpuchi n'etiti ikuku ọ bụla na-aga n'ụwa na n'etiti ikuku.

4. Nleta Mba {{1}Ibu ibu na nke dị ugbu a

5. Nnwale anabatara voltaji

6. Nleta nke Mkpirisi Mkpebi Mkpebi na Mfu ibu

7. Nnwale voltaji etinyere (AV)

8. Nnwale mmanụ

9. Nnwale ntapu site na nrụgide maka mmiri mmiri{1}}Mgbanwe imikpu (nnwale ike)

 

power distribution transformer testing
power distribution transformer FAT

 

 

04 Mbukota na mbupu

power distribution transformer packing

power distribution transformer shipping

 

05 Saịtị na nchịkọta

Igwe ngbanwe ike nkesa bụ ihe dị mkpa dị mkpa na sistemu ike, na-ahụ na nnyefe na nkesa ike dị mma, kwụsie ike na nchekwa.Ihe ntụgharị anyịEjiri teknụzụ dị elu rụọ ya na ụkpụrụ nrụpụta siri ike, na-ekwe nkwa ịdị mma pụrụ iche na arụmọrụ a pụrụ ịdabere na ya. Ha na-enye nkwado siri ike maka ụlọ ọrụ mmepụta ihe, azụmahịa, na ngwa akụrụngwa ọha. Site n'ịhọrọ ngwaahịa anyị, ị ga-enweta ihe ngwọta ike na-adịgide adịgide na nke a pụrụ ịdabere na ya, na-ewere nzọụkwụ na anyị iji nweta ọdịnihu dị mma na nke ga-adịgide adịgide!